INSTALLATION
AND SERVICE MUST BE PERFORMED BY
A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
if the information
in this manual
is not followed
exactly,
a fire or explosion
may
result
causing property
damage,
personal
injury
or death.
FOR YOUR SAFETY:
--
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
--
WHATTO
DO IFYOU SMELLGAS:
•
Do nottrytolightanyappliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Immediately
call your gas supplier from a neighbor's
phone.
Follow the gas supplier's
instructions.
•
If you cannot reach your gas supplier, call the fire department.
--
Installation
and service must be performed
by a qualified
installer,
service agency or the gas supplier.
Do not pinch the power supply cord or the flexible gas
conduit
between
the range and the wall.
Do not seal the range to the side cabinets.
**NOTE:
30" (76.2 cm) minimum
clearance between the
cooktop
and the bottom
of the cabinet when the bottom
of wood or metal cabinet is protected
by not less than F4"
(0.64 cm) flame retardant
millboard
covered with not less
than No. 28 MSG sheet metal, 0.015" (0.4 rnm)stainless
steel, 0.024"
(0.6 mrn) aluminum,
or 0.020"
(0.5 mrn)
copper.
Shave Raised Edge
to Clear
30" Min.
13"
31 1/2" (81 cm)
76.2 crn Min.
(33 cm)
Wide Cooktop
Rim
1 Y_" Max.
(13.8 crn Max.)
Min.)
From Wall
"q,
18" Min.
(45.7 cm) Min.
36" (91.4 cm) minimum
clearance when the cabinet is
unprotected.
• NOTE: Allow at
least 19 F4" (48.9
crn) clearance for
door depth when
it is open.
S
• Door Open
(see
jJJ_i
C ¸
jJ
z
_"
1 5/16"
_,21
3/4" _W/ (3.33 cm)
_/55.5 cm/ .......
A
?
2
g lator
._ . ....
B
Locate Cabine
Doors 1" (2.5
crn) Min.
from Cutout
Opening.
* Note:
For 29" (73.7
crn) cutout wide
opening, you must call
for optional
side
panels and clear wide
cooktop
rim as shown
in the "Countertop
Preparation"
section
(see page 3).
i¸¸
I
iL
A
HE GHT
BIWIDTH
35 318" (90 cm)
30"
36 3/8" (92 cm)
(76,2 cm)
Grounded
rction Box or Wall
Outlet Should Be Located 8" to
17" (20.3 cm to 43.2 cm) From
Right Cabinet and 2" to 4" (5.1
crn to 10.2 cm) From Floor.
C. DEPTH
F.MINIMUM
IS cuToUT
'
H HEIGHT
TO FRONT
CUTOUT
'
" _
OF RANGE
WDTH
DEPTH
couN_mToP
28 5/16"
30"
21 3/4" (55,2 crn) Min.
36" (91,4 crn) standard
(71,9 crn)
(76,2 cm)
22 1/8" (56,2 cm) Max.
35 3/8" (90 crn) rnin.
--e
FRONT
OF
CABINET
24" Min.
(61 crn Min.
22 7/8" *
(58.1 crn) rnin.
__ 23 1/4"*
__1 1/8"
(2.86 crn)
Ref.
G. Minimum
Cutout
Depth
is increased
to 24"
(61 cm) with
backguard.
NOTE: Wiring
diagram
for these appliances
are enclosed
in this
booklet.
¢-_
Recycled paper
* For cutouts be ow 22 7/8", appli_ nce
will slightly show out of the cabinet.
P/N 318201663
(0305)
Rev. A
Installation instructions - pages 1-9
Wiring Diagram - page 10