Download Print this page

Frigidaire CRA123KT11 Installation Instructions Manual

Slider casement air conditioners
Hide thumbs Also See for CRA123KT11:

Advertisement

READ BEFORE iNSTALLiNG
UNiT
For Slider Casement Air Conditioners
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp
edges that may be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to
move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over
an extended period of time.
Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp
metal fins of front and rear coils.
Make sure air conditioner does not fall during installation.
® These instructions describe installation in a typical wood framed window with a wood SLIDE=BY sash, or
installation in a metal CASEMENT window. Modification may be necessary when installing in windows made
differently than those shown in these instructions.
A high window accessory kit is available for window heights up to 62" (1575 mm). Part # EA103W.
Meeting
Electrical
Requirements
Electrical Shock and Personal Injury Hazard
® Electrical ground is required on this appliance.
• DO NOT ground to a gas line.
• If cold water pipe is interrupted by plastic, non-metallic gaskets, or other insulating materials, DO NOT use for
grounding.
• Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
• DO NOT modify power supply cord plug. If it does not fit outlet, have a proper outlet installed by a qualified
electrician.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral, or grounding circuit could result in
an electrical shock.
• DO NOT use an extension cord with this appliance.
Failure to follow these instructions could result in electrical shock, serious injury, or death.
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES.
DO NOT, UNDERANY
CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD GROUNDING PRONG.
® If codes permit, and a separate grounding wire is used, it is recommended that a qualified electrician determine
that the grounding path is adequate and not interrupted by plastic, non-metallic gaskets, or other insulating
materials.
2020213A0595

Advertisement

loading

Summary of Contents for Frigidaire CRA123KT11

  • Page 1 READ BEFORE iNSTALLiNG UNiT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed: Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit.
  • Page 2: Electrical Requirements

    Receptacle Wiring: Receptacle wiringshould bea minimum of 14gauge. U secopper w ireonly.It isyourresponsibility to provide proper andadequate r eceptacle w iring,installed bya qualified electrician. Electrical R equirements: A 115 volt(103.5 minimum, 126.5 maximum), 60 Hertz, A Conly,15ampere fusedelectrical supply is required. Atime delayfuseor timedelay circuit b reaker i s alsorequired.
  • Page 3 FIGo3 H Makesureyouhaveallthenecessary p arts. 9or 10or 11 Installation kit contents (FIG.3): Hardware Qty. Hardware Qty. Screw #10 x 1-3/4" flat-head Platform Screw #10 x 1" pan-head Support brace Screw #8 x 3/4" pan-head Adjustment bolt Hex flange nut- 1/4 Screw #8 x 3/4"...
  • Page 4 Choose the proper window location. FIG.5 Choose a window that allows the cooled air to flow freely and directly into room(s) you wish to cool. Remember, it is difficult to move air around corners. Also, choose a window that is within 6 feet of an electrical outlet as shown (FIG.5).
  • Page 5 Place platform assembly, with platform tab against inside of window Outside edge is 3/16" track, and attach it to window jamb (FIG. 11). Use appropriate length screws items 9-11 in preparing For installation). FIG.11 __ Adjust platform assembly so that outside edge is 3/16" lower than Put platform inside edge, as shown (FIG.11).
  • Page 6 Slide inner window sash firmly against side of the cabinet. Make sure not to peel the seal strips from the window track and cabinet side channels. If the panel frame does not fit snugly to the inner window sash, secure the panel frame to the sash with #8 x 3/4"...
  • Page 7 + If you are planning to use a siding-protection board (see Step 29) on the outside of your house, hold the board in place when testing the assembly in the window. Drill a 9/64" diameter pilot hole in the window jamb an equal distance from each side of the jamb (FIG.22), and 3/16"...
  • Page 8 _Cut side channel seal into 2 equal lengths. Remove the protective backing and apply it to the rear side of the cabinet side channels, starting just below the panel frame assembly. Pinch off excess length so the seal is even with the bottom of the cabinet side channel (FIG.29).

This manual is also suitable for:

Cra103kt10Cra123kt10Cra103kt11Cra084kt70Cra084kt71