Whirlpool WED97HEXL0 Installation Instructions Manual

Electric dryer

Advertisement

Quick Links

ELECTRIC
DRYER INSTALLATION
INSTRUCTIONS
Para una version de estas instrucciones
en espa_ol, visite www.Whirlpool.com
Table
of Contents
DRYER SAFETY .........................................................................
2
.............................................
3
Tools and Parts ......................................................................
3
....................................................
4
................................................
4
INSTALL LEVELING LEGS .........................................................
6
ELECTRICAL INSTALLATION ...................................................
7
Power Supply Cord Connection ...........................................
8
Direct Wire Connection .......................................................
10
VENTING ...................................................................................
13
.........................................................
13
Plan Vent System .................................................................
14
Venting Kits ..........................................................................
14
Install Vent System ..............................................................
15
INLET HOSE ..........................................................
16
CONNECT VENT ......................................................................
17
LEVEL DRYER ..........................................................................
18
CHECKLIST ..............................
18
DOOR REVERSAL (OPTIONAL} ..............................................
19
iNSTALLATiON
NOTES
Date of purchase:
Date of installation:
Installer:
Model number:
Serial number:
W10057363A
W10310420A
=SP

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool WED97HEXL0

  • Page 1: Table Of Contents

    ELECTRIC DRYER INSTALLATION INSTRUCTIONS Para una version de estas instrucciones en espa_ol, visite www.Whirlpool.com Table of Contents DRYER SAFETY ................. INSTALLATION REQUIREMENTS ..........Tools and Parts ..............LOCATION REQUIREMENTS ............ ELECTRICAL REQUIREMENTS ..........INSTALL LEVELING LEGS ............ELECTRICAL INSTALLATION ...........
  • Page 2: Dryer Safety

    DRYER S_ETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER"...
  • Page 3: Installation Requirements

    LATION REQUIREMENTS TOOLS PARTS Gather the required tools and parts before starting installation. Tools needed: Parts needed: (Not supplied with dryer) [] Vent clamps [] Vent elbows and ductwork Additional parts may be required, depending in your installation. Check local codes. Check existing electrical supply and venting. See "Electrical Requirements"...
  • Page 4: Location Requirements

    DRYER DIMENSIONS LOCATXON REQUXREMENT$ Check code requirements. Some codes limit, or do not permit, Front view: installing dryer in garages, closets, mobile homes, or sleeping ram) (686 quarters. Contact your local building inspector. © 381/8" (968 ram) Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer.
  • Page 5 IMPORTANT: Do not operate, install, or store dryer where ELECTRIC, REQUIREMENW$ it will be exposed to water, weather, or at temperatures below 45 ° F (7° C). Lower temperatures may cause dryer not to it is your responsibility: shut off at end of automatic sensor cycles, resulting in longer [] To contact a qualified electrical installer.
  • Page 6: Install Leveling Legs

    if your outlet looks like this: INS%ALL LE¥ L[NG LEGS Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have four 10-gauge Excessive Weight Hazard copper wires and match a 4-wire receptacle of Use two or more people to move and install dryer.
  • Page 7: Electrical Installation

    ELECTRIC LATION For direct wire installations: For power supply cord installations: Fire Hazard Fire Hazard Use 10 gauge copper wire. Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Use a UL listed strain relief. Disconnect power before making electrical connections.
  • Page 8: Power Supply Cord Connection

    Power Supply Cord Connection Power supply cord strain relief: 4=Wire Power Supply Cord Connection IMPORTANT: A 4-wire connection is required for moble homes and where local codes do not 3ermit the use of 3-wire connections. 4-wire receptacle (NEMA 4-prong plug type 14-30R) Remove the screws from a 3/4"...
  • Page 9 . Remove center screw Connect ground wire Connect ground wire (F) (green or bare) of power supply cord Remove center, silver-colored terminal block screw (B). to external ground conductor screw (A). Tighten screw. Connect neutral wire Connect neutral wire (white or center) (C) of power supply cord to center, silver-colored terminal block screw (B).
  • Page 10: Direct Wire Connection

    Direct Wire Connection Direct wire strain relief 4=Wire Direct Wire Connection iMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections. "1, Prepare your 4=wire cable for direct connection Unscrew the removable conduit connector (A) and any Direct wire cable must have 5 ft.
  • Page 11 3=Wire Direct Wire Connection Connect neutral ground wire and neutral wire Use where local codes permit connecting cabinet-ground conductor to neutral wire. Prepare your 3=wire cable direct connection Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire Direct wire cable must have 5 ft.
  • Page 12 Connect remaining wires neutral wire .=====_== Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal Connect neutral ground wire (E) and neutral wire (white or block cover into slot of dryer rear panel.
  • Page 13: Venting

    Exhaust hoods: [] An exhaust hood should cap the vent to keep rodents and Venting Requirements insects from entering the home. [] Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).
  • Page 14: Plan Vent System

    Plan Vent System Choose your exhaust installation type Determine vent path: [] Select route that will provide straightest and most direct Recommended exhaust installation: path outdoors. [] Plan installation to use fewest number of elbows and turns. [] When using elbows or making turns, allow as much room as possible.
  • Page 15: Install Vent System

    CONNECT INLET HOSE Install Vent System The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses. install exhaust hood Turn cold water off, remove replace rubber washer ,9--12" rnin. ® (305 ram) ®...
  • Page 16: Connect Inlet Hose

    and tighten coupling Using pliers, tighten the couplings with additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupling can result. Attach other end of long hose Attach long hose to "Y" to fill valve at bottom of dryer connector and tighten couplings...
  • Page 17: Connect Vent

    CONNECT Connect vent to exhaust outlet Place level here © Using a 4" (102 mm) clamp, connect vent to exhaust outlet Check levelness of dryer from in dryer. If connecting to existing vent, make sure vent is side to side. Repeat from front to back. clean.
  • Page 18: Level Dryer

    LE L COMPLETE INSTALLATION Level Dryer Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped. Check that you have all of your tools. Place level here Dispose of/recycle all packaging materials. Be sure the water faucets are on.
  • Page 19: Door Reversal

    2, Move the door strike DOOR RE %RS, (OPTION, } The following instructions are for models with a round-shaped door. For models with a square shaped door, an additional kit is ® ® needed. Please contact your retailer, or see the For Assistance ®...
  • Page 20 Remove trim ring from outer Rotate and reassemble outer door window assembly and trim ring Using a Phillips screwdriver, remove the 6 screws from the outer window retainer and rotate the outer window assembly Align the notches on the outer door assembly with the tabs on clockwise until the square notches line up with the 4 tabs the trim ring and lower into place as shown in figure A.
  • Page 21 Latch Position the door with the inside of the door facing up. Reinstall the 10 screws securing the inner door to the outer door. Using a Torx ®T25 screwdriver, remove the 3 Torx screws securing the latch plate and latch backing plate and the 5 screws holding the hinge assembly in place.
  • Page 24 W10057363A W10310420A = SP © 2010 07/10 Printed in U.S.A. All rights reserved...

This manual is also suitable for:

Wed97hexr0Wed97hexw0

Table of Contents