Panasonic CZ-01ESM11P Operation Manual
Panasonic CZ-01ESM11P Operation Manual

Panasonic CZ-01ESM11P Operation Manual

Packaged air conditioner central remote controller

Advertisement

PACKAGED AIR CONDITIONER

CENTRAL REMOTE CONTROLLER

Model No.
CZ-01ESM11P
Thank you for purchasing Panasonic's central remote controller.
For proper usage, read this instruction manual carefully before using this unit.
This manual will help you with anything you can not understand or should anything go wrong with the unit during
use.
Keep this manual handy for future reference.
NOTES:
This unit is connected to multiple air conditioners. Keep the installation list showing the configurations together
with this manual.
Wir danken Ihnen für den Kauf der zentralen Fernbedienung von Panasonic.
Lesen Sie bitte diese Anleitung bevor Sie das Gerät in Betrieb setzen durch, um es richtig zu verwenden.
Diese Anleitung wird Ihnen Ungewißheiten aufzuklären oder evtl. auftretende Betriebsstörungen zu korrigieren
helfen.
Bewahren Sie diese Anleitung für spätere Bezungnahme griffbereit auf.
HINWEISE:
Dieses Gerät ist an mehrfache Klimageräte angeschlossen. Bewahren Sie die Installationsliste, aus der die
Konfiguration ersichtlich ist, zusammen mit dieser Anleitung auf.
Before operating this set, please read these instructions completely

OPERATION MANUAL

En.
Ge.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic CZ-01ESM11P

  • Page 1: Operation Manual

    This unit is connected to multiple air conditioners. Keep the installation list showing the configurations together with this manual. Wir danken Ihnen für den Kauf der zentralen Fernbedienung von Panasonic. Lesen Sie bitte diese Anleitung bevor Sie das Gerät in Betrieb setzen durch, um es richtig zu verwenden.
  • Page 2: Features And Functions

    FEATURES AND FUNCTIONS I Operation menu This central remote controller enables the individual operation/stop See page by zone, and unified operation/stop. ON/OFF operation controlled by 22—23, 31. timer is possible in conjunction with the schedule timer (optional accessory). I Various operation modes. You can operate the system from both this unit and the remote controller, so to enable various operation control patterns.
  • Page 3 NAMES AND FUNCTIONS OF THE OPERATING SECTION (Fig. 1, 2) UNIFIED OPERATION BUTTON “ ” DISPLAY (PRESET TEM- PERATURE) Press to operate all indoor units. Displays the preset temperature. UNIFIED STOP BUTTON CODE “ ” DISPLAY (CONTROL Press to stop all indoor units. MODE) OPERATION LAMP (RED) Displays codes on how to control equipment...
  • Page 4 “ ” “ ” DISPLAY (TIME TO TEMPERATURE SETTING BUT- CLEAN AIR CLEANER ELEMENT/ TIME TO CLEAN AIR FILTER) Press to set temperature. Displayed to notify the user it is time to clean TIME NO. BUTTON the air filter or air cleaner element of the group displayed.
  • Page 5 In the above example, the zone No. 2 is displayed. ZONE SETTING (Fig. 3) Then, the display “ I ” of the lowest group No. that has already been set lights up. You can set multiple groups under a single zone to control them by zone.
  • Page 6: Operation

    OPERATION Press the TIMER ON BUTTON. Press the TIMER ON BUTTON within 10 seconds after the code No. is OPERATION BY ZONE displayed. The display stops flash- (Fig. 4) ing and lights up solidly. The display CODE CODE Flow of operation by zone returns to its original state Call up the desired zone.
  • Page 7 Cooling mode Unified operation is not is selected. set within the zone. Press the TEMPERATURE SET- TING BUTTON. Each time you press the “ ”, the ° temperature rises by 1 Each time you press the “ ”, the ° temperature falls by 1 If you don’t wish to execute the unified setting in the zone, set it to...
  • Page 8: Operation Mode

    OPERATION MODE The following five operation control modes can be selected along with the temperature setting and operation mode by remote controller, for a total of twenty different modes. These twenty modes are set and displayed with control modes of 0 to 19. (For further details, see EXAMPLE OF OPERATION SCHEDULE on the next page.) ●...
  • Page 9 Control by remote controller Operation Operation Control Operation mode Unified operation, individual Unified stop, indivi- Tempera- Stop mode mode operation by central remote dual stop by central ture control setting controller, or operation remote controller, or controlled by timer timer stop Acceptance Rejection Rejection...
  • Page 10 Only OFF control possible by remote controller Timer stops even Operation Operation Centralized SET1 if you forget to controlled by controlled turn off the unit. timer by timer Programmed to Programmed to Programmed to - - - - - - SET2 Stop operate at 5:20...
  • Page 11 ● List of setting operation SETTING OPERATION MODE (Fig. 5) Zones not displayed Display Setting Contents of setting ● The Zone consists of the following two cases. To be set by zone A. Zone without display “ ” To be set by zone The group with master remote controller setting ❈...
  • Page 12: Group Monitoring

    ❈2: The group on FAN operation in the zone GROUP MONITORING performs the temperature control opera- (Fig. 7) tion (cool/heat) under the outdoor refrigerant system. Utilize the group monitor function in each of the TEMPERATURE SETTING following cases: 1. Check the malfunction code. (See the next (Fig.
  • Page 13 Check the contents of remote controller for all the groups the display, and contact your Panasonic dealer sharing the same outdoor unit or BS because the above signs can give you the idea on the unit.
  • Page 14 NOTES FUNCTION OF ● Unless operated from within one minute from REFRIGERANT SYSTEM when the refrigerant system display, the display will automatically revert back to the “group” DISPLAY (Fig. 10) display. ● This function may not be available depending on the type of outdoor unit with which the unit is The following information becomes available by connected.
  • Page 15 UNIFIED OPERATION (Fig. 12) Use this function when executing operation and stop of all the connected indoor units. Unified operation Press the UNIFIED OPERATION BUTTON. All the displays “ ” of the group No. in operation light up at the same time, and all the groups start to operate at the same time.
  • Page 16: Installation Table

    Installation table When installing the equipment, mark the zone No. of each group and installation location in the below table. Setting group No. Operated by simplified remote controller (Setting is not possible unless power is activated to both the central 1.
  • Page 17 Matsushita Electric Industrial Co., Ltd. Web Site : http://www.panasonic.co.jp/global/ 3VA10582-7A EM01A044 (0110) HT...