HP ProLiant DL320 G6 Server User Manual

HP ProLiant DL320 G6 Server User Manual

Hp proliant dl320 g6 server
Hide thumbs Also See for ProLiant DL320 G6 Server:
Table of Contents

Advertisement

HP ProLiant DL320 G6 Server

User Guide

Part Number 530514-001
April 2009 (First Edition)

Advertisement

Table of Contents
loading

Summary of Contents for HP ProLiant DL320 G6 Server

  • Page 1: User Guide

    HP ProLiant DL320 G6 Server User Guide Part Number 530514-001 April 2009 (First Edition)
  • Page 2 © Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3: Table Of Contents

    Contents Component identification ....................... 7 Front panel components ..........................7 Front panel LEDs and buttons ........................8 SAS and SATA device numbers........................9 Rear panel components..........................9 Rear panel LEDs and buttons........................10 PCI expansion slot definitions........................10 System board components........................11 System maintenance switch......................
  • Page 4 HP ROM-Based Setup Utility......................50 Array Configuration Utility ......................52 Option ROM Configuration for Arrays ..................... 52 HP ProLiant Essentials Rapid Deployment Pack .................. 53 Re-entering the server serial number and product ID ................53 Management tools........................... 54 Automatic Server Recovery ......................54 ROMPaq utility..........................
  • Page 5 Electrostatic discharge ......................... 85 Preventing electrostatic discharge ......................85 Grounding methods to prevent electrostatic discharge .................. 85 Specifications ..........................86 Environmental specifications ........................86 Mechanical specifications ........................86 Power supply specifications ........................87 Technical support........................89 Before you contact HP..........................89 Contents 5...
  • Page 6: Contents

    HP contact information ..........................89 Customer Self Repair ..........................89 Acronyms and abbreviations......................97 Index............................100 Contents 6...
  • Page 7: Component Identification

    Component identification Front panel components • LFF models Item Description Optical drive blank Serial label pull tab USB connectors (2) Hard drive bays • SFF models Item Description Optical drive blank Serial label pull tab USB connectors (2) Hard drive bays Component identification 7...
  • Page 8: Front Panel Leds And Buttons

    Front panel LEDs and buttons Item Description Status Internal health LED Green = System health is normal. Amber = System health is degraded. To identify the component in a degraded state, see "System board LEDs (on page 13)." Red = System health is critical. To identify the component in a critical state, see "System board LEDs (on page 13)."...
  • Page 9: Sas And Sata Device Numbers

    SAS and SATA device numbers Rear panel components For this server model, PCI expansion slots 1-3 and 6 are reserved. Item Description Power cord connector Mouse connector 10/100/1000 NIC 1 connector/shared iLO 2 management port 10/100/1000 NIC 2 connector Serial connector Slot 5 PCIe2 x16 (4, 2, 1) Slot 4 PCIe2 x16 (16, 8, 4, 1) UID button/LED...
  • Page 10: Rear Panel Leds And Buttons

    Rear panel LEDs and buttons Item Description Status UID button/LED Blue = Activated Flashing = System is being managed remotely. Off = Deactivated NIC/iLO 2 link Green or flashing green = Activity exists. Off = No activity exists. NIC/iLO 2 activity Green = Link exists.
  • Page 11: System Board Components

    System board components For this server, some system board slots and connectors are reserved. Item Description Reserved SD card connector PCIe riser board connectors Reserved Fan 6 connector (reserved) Dedicated iLO 2 module connector (optional) System maintenance switch NMI jumper System battery TPM connector DIMM slots 1-9...
  • Page 12: System Maintenance Switch

    Item Description USB tape drive connector Redundant power supply connector Front panel connector Fan 7 connector SATA connectors 1-4 (hard drives) Hard drive backplane connector SATA connectors 5-6 (optical drives)** * Fan 5 is only available in CTO models of this server. **The server supports one optical drive that can be connected to either SATA connector 5 or SATA connector 6.
  • Page 13: System Board Leds

    • Short the NMI jumper pins • Press the NMI switch • Use the iLO Virtual NMI feature For additional information, see the whitepaper on the HP website (http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf). System board LEDs Item LED description Status Fan 6 failure —...
  • Page 14: System Leds And Internal Health Led Combinations

    Combinations of illuminated system LEDs and the internal health LED indicate system status. The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM may report server status differently than the health LEDs because the software tracks more system attributes.
  • Page 15: Fan Locations

    System LED and Internal Health Status Color LED Color The server has detected a hardware critical temperature level. Fan module (amber) The minimum fan requirements are not being met in one or more of the fan modules. One or more fans have failed or are missing.
  • Page 16: Operations

    To remove the server from an HP, Compaq branded, telco, or third-party rack: Power down the server (on page 16). Disconnect all peripheral cables and power cords from the server rear panel.
  • Page 17: Remove The Access Panel

    Remove the server from the rack. For more information, see the documentation that ships with the rack mounting option. Place the server on a sturdy, level surface. Remove the access panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
  • Page 18: Remove The Pci Riser Board Assembly

    Remove the PCI riser board assembly CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the PCI riser board assembly. Power down the server (on page 16). Remove the server from the rack (on page 16).
  • Page 19 Install the PCI riser board assembly. Connect any internal cables for expansion boards. Install the access panel. Install the server into the rack. Operations 19...
  • Page 20: Setup

    (http://www.hp.com/hps/carepack/servers/cp_proliant.html). Rack planning resources The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks. For more information on the content of each resource, refer to the rack resource kit documentation. If you intend to deploy and configure multiple servers in a single rack, refer to the white paper on high- density deployment at the HP website (http://www.hp.com/products/servers/platforms).
  • Page 21: Optimum Environment

    HP servers draw in cool air through the front door and expel warm air through the rear door. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet, and the rear door must be adequately ventilated to allow the warm air to escape from the cabinet.
  • Page 22: Power Requirements

    Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a PDU that is either permanently wired to the building’s branch circuit or includes a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose.
  • Page 23: Rack Warnings

    Rack warnings WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: The leveling jacks are extended to the floor. • The full weight of the rack rests on the leveling jacks. • • The stabilizing feet are attached to the rack if it is a single-rack installation.
  • Page 24: Installing The Server Into The Rack

    If you are installing the server into a telco rack, order the appropriate option kit at the RackSolutions.com website (http://www.racksolutions.com/hp). Follow the server-specific instructions on the website to install the rack brackets. Use the following information when connecting peripheral cables and power cords to the server.
  • Page 25: Installing The Operating System

    NOTE: For SATA RAID configuration, a driver diskette must be created. For information on using these installation paths, refer to the SmartStart installation poster in the HP ProLiant Essentials Foundation Pack, included with the server. Powering up and configuring the server...
  • Page 26: Hardware Options Installation

    Hardware options installation Introduction If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
  • Page 27: Single-, Dual-, And Quad-Rank Dimms

    Channel Slot Slot number This multi-channel architecture provides enhanced performance in Advanced ECC mode. This architecture also enables the Mirrored Memory and Lockstep memory modes. This server supports both Registered PC3 DIMMSs (RDIMMs) and Unbuffered DIMMs (UDIMMs). DIMM slots in this server are identified by number and by letter. Letters identify the slots to populate for specific AMP modes.
  • Page 28: Memory Configurations

    8500 = 1067-MHz DIMM type R = RDIMM (registered) E = UDIMM (unbuffered with ECC) For the latest supported memory information, see the QuickSpecs on the HP website (http://www.hp.com). Memory configurations To optimize server availability, the server supports the following AMP modes: •...
  • Page 29: General Dimm Slot Population Guidelines

    DIMM configuration, the server boots in Advanced ECC mode. For more information, see "HP ROM-Based Setup Utility (on page 50)." For the latest memory configuration information, see the QuickSpecs on the HP website (http://www.hp.com). RDIMM maximum memory configurations The following table lists the maximum memory configuration possible with 8-GB RDIMMs.
  • Page 30: Advanced Ecc Population Guidelines

    • Each channel supports up to two Unbuffered DIMMs. • If quad-rank DIMMs are installed for a processor, a maximum of two DIMMs can be installed on each channel for that processor. • If a channel contains quad-rank DIMMs, the quad-rank DIMM must be installed first on that channel. DIMM speeds are supported as indicated in the following table.
  • Page 31: Installing A Dimm

    Install the air baffle. Install the access panel. If you are installing DIMMs in mirrored or lock-step configuration, configure this mode in RBSU ("HP ROM- Based Setup Utility" on page 50). For more information about LEDs and troubleshooting failed DIMMs, see "System LEDs and internal health LED combinations (on page 14)."...
  • Page 32: Redundant Hot-Plug Power Supply Option

    Redundant hot-plug power supply option To install the component: Remove the power supply blank. Install the power supply. Connect the power cord to the power supply. Connect the power cord to the AC power source. Hard drive options The server provides non-hot-plug capability through an embedded SATA controller. To obtain hot-plug capability, install an optional controller and hot-plug cable option kit.
  • Page 33: Removing A Hard Drive Blank

    • Drives must be the same capacity to provide the greatest storage space efficiency when drives are grouped together into the same drive array. Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options are: • The embedded controller supports non-hot-plug SATA hard drives. Drive LEDs are not supported. •...
  • Page 34: Installing A Hard Drive

    Remove the hard drive. Installing a hard drive IMPORTANT: Hot-plug capability and drive LED support are only available when a supported optional controller is installed in the server. Power down the server (on page 16). Remove the existing hard drive blank. Prepare the hard drive.
  • Page 35: Optical Drive Option

    Install the hard drive. Optical drive option To install the component: Power down the server (on page 16). Remove the server from the rack (on page 16). Remove the access panel (on page 17). Remove the air baffle (on page 17). Remove the 9.5-mm optical drive blank.
  • Page 36 Install the 9.5-mm optical drive assembly. When fully inserted, the assembly locking latch clicks. Using a T-15 screwdriver, secure the drive to the chassis. Connect the optical drive and power cable to the optical drive. Hardware options installation 36...
  • Page 37: Dedicated Ilo 2 Port Module Option

    Route the cable, and then connect the SATA connector to the system board. Connect the power connector to the power supply backplane. Install the access panel. Install the server into the rack. Dedicated iLO 2 port module option To install the component: Power down the server (on page 16).
  • Page 38: Expansion Board Option

    Using a T-15 Torx screwdriver, install the dedicated iLO 2 management port module. Install the access panel. Install the server into the rack. Expansion board option To install the component: Power down the server (on page 16). Remove the server from the rack (on page 16). Remove the access panel (on page 17).
  • Page 39: Pci-X Riser Board Option

    Install the expansion board. IMPORTANT: The server does not power up if the PCI riser board assembly is not seated properly. Install the PCI riser board assembly (on page 18). Connect all internal cables for expansion boards. Install the access panel. Install the server into the rack.
  • Page 40: Storage Controller Option

    Remove the PCIe riser board from the assembly. Install the optional PCI-X riser board. Install a PCI-X expansion board ("Expansion board option" on page 38). IMPORTANT: The server does not power up if the PCI riser board assembly is not seated properly.
  • Page 41: Battery-Backed Write Cache Battery Pack Option

    IMPORTANT: The server does not power up if the PCI riser board assembly is not seated properly. Install the PCI riser board assembly (on page 18). Connect the mini-SAS to mini-SAS cable, provided in the mini-SAS to mini-SAS cable option kit, to the hard drive backplane and to the storage controller.
  • Page 42 Install the cache module on the controller. Connect the cable to the cache module. Hardware options installation 42...
  • Page 43: Hp Trusted Platform Module Option

    Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system board. • When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology. For security reasons, only the customer can enable these features. •...
  • Page 44: Installing The Trusted Platform Module Board

    Recovery Mode after BitLocker™ detects a possible compromise of system integrity. • HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see the encryption technology feature documentation provided by the operating system.
  • Page 45: Retaining The Recovery Key/Password

    Install the TPM security rivet by pressing the rivet firmly into the system board. Install the access panel. Install the server into the rack. Power up the server (on page 16). Retaining the recovery key/password The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after BitLocker™...
  • Page 46 OS application TPM settings. For more information on firmware updates and hardware procedures, see the HP Trusted Platform Module Best Practices White Paper on the HP website (http://www.hp.com/support).
  • Page 47: Cabling

    Cabling Cabling overview This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance. Server cabling CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or air flow can be blocked.
  • Page 48: Bbwc Battery Pack Cabling To An Optional Controller

    BBWC battery pack cabling to an optional controller Cabling 48...
  • Page 49: Configuration And Utilities

    This automated server configuration process cuts time from each server deployed, making it possible to scale server deployments to high volumes in a rapid manner. For more information, and to download the SmartStart Scripting Toolkit, refer to the HP website (http://www.hp.com/servers/sstoolkit).
  • Page 50: Hp Rom-Based Setup Utility

    Selecting the primary boot controller • Configuring memory options • Language selection For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation). Using RBSU To use RBSU, use the following keys: •...
  • Page 51: Boot Options

    RBSU by pressing the F9 key when prompted. After the settings are selected, exit RBSU and allow the server to reboot automatically. For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation).
  • Page 52: Array Configuration Utility

    Servers running Microsoft® operating systems require Internet Explorer 5.5 (with Service Pack 1) or later. For Linux servers, refer to the README.TXT file for additional browser and support information. For more information, refer to the Configuring Arrays on HP Smart Array Controllers Reference Guide on the Documentation CD or the HP website (http://www.hp.com).
  • Page 53: Hp Proliant Essentials Rapid Deployment Pack

    It enables you to perform imaging or scripting functions and maintain software images. For more information about the RDP, refer to the HP ProLiant Essentials Rapid Deployment Pack CD or refer to the HP website (http://www.hp.com/servers/rdp).
  • Page 54: Management Tools

    ASR increases server availability by restarting the server within a specified time after a system hang or shutdown. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the HP SIM console or through RBSU.
  • Page 55: Storageworks Library And Tape Tools

    You must install and use HP SIM to benefit from the Pre-Failure Warranty for processors, SAS and SATA hard drives, and memory modules. For additional information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack or the HP SIM website (http://www.hp.com/go/hpsim).
  • Page 56: Usb Support

    ROM. USB support HP provides both standard USB support and legacy USB support. Standard support is provided by the operating system through the appropriate USB device drivers. HP provides support for USB devices prior to the operating system loading through legacy USB support, which is enabled by default in the system ROM.
  • Page 57: Hp Insight Diagnostics Survey Functionality

    For more information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack. Array Diagnostic Utility The HP Array Diagnostics Utility is a web-based application that creates a report of all HP storage controllers and disk drives. This report provides vital information to assist in identifying faults or conditions that may require attention.
  • Page 58: Hp Insight Remote Support Software

    HP servers, storage, network and SAN environments, plus selected Dell and IBM Windows servers that have a support obligation with HP. It also enables HP to deliver higher levels of proactive support in line with HP Mission Critical Services support agreements.
  • Page 59: Proliant Support Packs

    To download the tool and for more information, see the HP website (http://www.hp.com/support). Change control and proactive notification HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products.
  • Page 60: Care Pack

    Care Pack HP Care Pack Services offer upgraded service levels to extend and expand standard product warranty with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. Refer to the Care Pack website (http://www.hp.com/hps/carepack/servers/cp_proliant.html). Configuration and utilities 60...
  • Page 61: Troubleshooting

    Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, error message interpretation, issue resolution, and software maintenance on ProLiant servers and server blades. This guide includes problem- specific flowcharts to help you navigate complex troubleshooting processes.
  • Page 62: Symbols On Equipment

    Warnings and cautions WARNING: Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board.
  • Page 63: Symptom Information

    WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: The leveling feet are extended to the floor. • • The full weight of the rack rests on the leveling feet. The stabilizing feet are attached to the rack if it is a single-rack installation. •...
  • Page 64: Prepare The Server For Diagnosis

    To verify the server configuration, connect to the System Management homepage and select Version Control Agent. The VCA gives you a list of names and versions of all installed HP drivers, Management Agents, and utilities, and whether they are up-to-date.
  • Page 65: Service Notifications

    Select the appropriate server model, and then click the Troubleshoot a Problem link on the product page. Troubleshooting flowcharts To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section, "Start diagnosis flowchart (on page 65)," and follow the appropriate diagnostic path. If the other flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis...
  • Page 66: General Diagnosis Flowchart

    Item Refer to "Symptom information (on page 63)" "Loose connections (on page 64)" "Service notifications (on page 65)" The most recent version of a particular server or option firmware is available on the HP Support website (http://www.hp.com/support). Troubleshooting 66...
  • Page 67 Item Refer to "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) Server maintenance and service guide, located on the Documentation CD or the HP website (http://www.hp.com/products/servers/platforms) •...
  • Page 68: Server Power-On Problems Flowchart

    Server power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber. Troubleshooting 68...
  • Page 69 Faulty internal component Item Refer to "Component identification (on page 7)" "HP Insight Diagnostics (on page 56)" or in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) "Loose connections (on page 64)"...
  • Page 70 Troubleshooting 70...
  • Page 71: Post Problems Flowchart

    "Symptom information (on page 63)" Server maintenance and service guide, located on the Documentation CD or the HP website (http://www.hp.com/products/servers/platforms) "Port 85 and iLO messages" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) "General memory problems are occurring"...
  • Page 72: Os Boot Problems Flowchart

    OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot SmartStart Possible causes: • Corrupted operating system • Hard drive subsystem problem • Incorrect boot order setting in RBSU Troubleshooting 72...
  • Page 73 Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) • Controller documentation "HP Insight Diagnostics (on page 56)" or in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) •...
  • Page 74: Server Fault Indications Flowchart

    Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents (on page 55) • Server boots, but the internal health LED, external health LED, or component health LED is red or amber Troubleshooting 74...
  • Page 75 CD or the HP website (http://www.hp.com/products/servers/platforms) • "HP contact information (on page 89)" "HP Insight Diagnostics (on page 56)" or in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) • "Hardware problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support)
  • Page 76: Post Error Messages And Beep Codes

    POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support). WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.
  • Page 77: Battery Replacement

    Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years. WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack.
  • Page 78 For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. Battery replacement 78...
  • Page 79: Regulatory Compliance Notices

    Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number.
  • Page 80: Declaration Of Conformity For Products Marked With The Fcc Logo, United States Only

    Hewlett-Packard Company P. O. Box 692000, Mail Stop 530113 Houston, Texas 77269-2000 • 1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded or monitored.) For questions regarding this FCC declaration, contact us by mail or telephone: • Hewlett-Packard Company P.
  • Page 81: Canadian Notice (Avis Canadien)

    Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Class B equipment This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
  • Page 82: Japanese Notice

    This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
  • Page 83: Chinese Notice

    • Allow only HP Authorized Service technicians to repair the unit. The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976.
  • Page 84: Taiwan Battery Recycling Notice

    To forward them to recycling or proper disposal, use the public collection system or return them to HP, an authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.
  • Page 85: Electrostatic Discharge

    Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
  • Page 86: Specifications

    Specifications Environmental specifications Specification Value Temperature Operating 10°C to 35°C (50°F to 90°F) Non-operating 30°C to 60°C (-22°F to 140°F) Maximum rate of temperature change Operating 10°C/hr (18°F/hr) Non-operating 20°C/hr (36°F/hr) Relative humidity (noncondensing)*** Operating 10% to 90% Non-operating 5% to 95% Maximum wet bulb temperature (non-condensing) Operating...
  • Page 87: Power Supply Specifications

    Power supply specifications Depending on installed options, the server is configured with one of the following power supplies: • HP ProLiant 400 W Power Supply Specification Value Input requirements Rated input voltage 100 to 120 VAC, 200 to...
  • Page 88 Maximum peak power 460 W at 100V to 120V AC input 460 W at 200V to 240V AC input • HP 500 W Power Supply Specification Value Input requirements Rated input voltage 100 to 120 VAC, 200 to 240 VAC...
  • Page 89: Technical Support

    If during the diagnosis period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts: •...
  • Page 90 HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days.
  • Page 91 La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.
  • Page 92 Si precisa asistencia técnica, puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán devolverse a HP.
  • Page 93 HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio. Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local.
  • Page 94 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
  • Page 95 Technical support 95...
  • Page 96 Technical support 96...
  • Page 97: Acronyms And Abbreviations

    Acronyms and abbreviations ABEND abnormal end Array Configuration Utility Automatic Server Recovery BIOS Basic Input/Output System double data rate International Electrotechnical Commission Integrated Lights-Out Integrated Management Log keyboard, video, and mouse NEMA National Electrical Manufacturers Association NFPA National Fire Protection Association network interface controller Acronyms and abbreviations 97...
  • Page 98 non-maskable interrupt NVRAM non-volatile memory ORCA Option ROM Configuration for Arrays peripheral component interface PCI Express Peripheral Component Interconnect Express PCI-X peripheral component interconnect extended power distribution unit POST Power-On Self Test ProLiant Support Pack RAID redundant array of inexpensive (or independent) disks RBSU ROM-Based Setup Utility Rapid Deployment Pack...
  • Page 99 SATA serial ATA SCSI small computer system interface Systems Insight Manager unit identification universal serial bus Version Control Agent Acronyms and abbreviations 99...
  • Page 100: Index

    ACU (Array Configuration Utility) 52 connection problems 64 additional information 61 connectors 7 ADU (Array Diagnostic Utility) 57 contacting HP 89 air baffle 17 crash dump analysis 12 airflow requirements 21 Altiris eXpress Deployment Server 53 Array Configuration Utility (ACU) 52...
  • Page 101 HP ProLiant Essentials Foundation Pack 55 Option ROM Configuration for Arrays (ORCA) 52 HP ProLiant Essentials Rapid Deployment Pack 53 options installation 23, 26 HP StorageWorks Library and Tape Tools (L&TT) 55 ORCA (Option ROM Configuration for Arrays) 52 HP website 89 passwords 45...
  • Page 102 21 SAS/SATA backplane 12 serial number 53 series number 79 warnings 23, 62 Server cabling 47 website, HP 89 server features and options 26 server, installation 24 site requirements 21 SmartStart autorun menu 49 SmartStart Scripting Toolkit 49 software 49...

Table of Contents