3.
Connect line 1 (black) and line 2 (red) wires
to the outer terminal block posts with 10-32
hex nuts.
4.
Securely tighten hex nuts.
NOTE: For power supply cord replacement, only
use a power cord rated at 250 volts minimum,
40 amps or 50 amps that is marked for use
with nominal 3/8" (3.5 cm) diameter connec-
tion opening, with ring terminals and marked
for use with ranges.
5.
Replace terminal block access cover.
Direct Wire Installation:
Copper or Aluminum Wire
This range may be connected directly to the fuse
disconnect or circuit breaker box. Depending
on your electrical supply, make the required
3-wire or 4-wire connection.
1.
Strip outer covering back 3" (7.6 cm) to
expose wires. Strip the insulation back 1"
(2.5 cm) from the end of each wire.
2.
Allow enough slack in the wire to easily
attach the wiring terminal block.
3.
Complete electrical connection according
to your type of electrical supply (4-wire or
3-wire connection).
1"
(2.5 cm)
3"
(7.6 cm)
2-12
4-wire Connection: Direct Wire
Use this method for: New branch-circuit instal-
lations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit ground-
ing through the neutral
1.
Part of metal ground strap must be cut out
and removed.
A. Metal ground strap
B. Ground-link screw
A
B