Invalid Values of
Monitoring Data
The monitoring data in the
CSV file includes "-5".
7-70
Hitachi Universal Storage Platform V/VM Hitachi Performance Manager User's Guide
When the CU number is not the monitoring target, Performance Monitor
cannot obtain monitoring data from the CU.
If the PG, LDEV, LU, RCLU, RCLDEV, URLU, or URLDEV operand is
specified, the value of the monitoring data is "-5". To solve this
problem, specify the CU as the monitoring target by using the
Monitoring Options window of Performance Monitor (not by using the
Export Tool). For details on specifying the CU as the monitoring target,
see Monitoring Options Window, and Table 4-4.
If the RemoteCopy, UniversalReplicator, or URJNL operand is specified,
the value "-5" is not output in the monitoring data though the CU
number is not the monitoring target. In this case, data on monitored
CUs are summed up and output into the CSV file.