Download Print this page
HP E7671A Installation Manual
HP E7671A Installation Manual

HP E7671A Installation Manual

Power distribution unit kit fits hp 19-inch racks

Advertisement

Quick Links

power distribution unit
kit
fits hp 19-inch racks
E7671A
E7674A
E7675A
E7676A

Advertisement

loading

Summary of Contents for HP E7671A

  • Page 1 E7671A power distribution unit E7674A E7675A fits hp 19-inch racks E7676A...
  • Page 2 Contents Notice The information contained in this document is subject to change without notice. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard Company shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
  • Page 3: Declaration Of Conformity

    Contents DECLARATION OF CONFORMITY according to ISO/IEC Guide 22 and EN 45014 Manufacturer's Name: Hewlett-Packard Company Manufacturer's Address: 10955 Tantau Avenue Cupertino, CA 95014 USA declares, that the product Product Name: Power Distribution Units Model Number(s): E7670-63001, E7671-63001, E7672-63001 E7674-63001, E7675-63001, E7676-63001 Product Options: conforms to the following Product Specifications: Safety:...
  • Page 4 T-25 Torx™ driver Overview The HP Power Distribution Units (PDUs) are designed to provide flexibility for your power requirements. The PDUs can be mounted both vertically and horizontally on the rear rack columns, depending on your rack configuration. Use the EIA holes for...
  • Page 5 Overview...
  • Page 6: Installation

    Installation Installation Caution: Turn off power to all devices in your rack before installing the PDUs. Note: Do not use sheet metal nuts to mount the PDU, because the sheet metal nuts do not assure positive grounding. Installing PDUs Vertically PDUs can be installed vertically on the rear rack columns.
  • Page 7 Installation 4. When connecting the PDU to the wall outlet, be sure to secure the main power cable with the clamp, as shown in the figure below. Tighten clamp around cable 5. Connect power cables from devices to the PDU, then connect PDU to the wall outlet or UPS. 6.
  • Page 8 Installation 3. Tighten the screws to force the star washers to pierce the paint and make solidcontact with the metal column. This connects the rack chassis with earth ground to protect against possible electric shock. 4. Connect the power cables from the devices to the PDU. 5.
  • Page 9: Electrical Connection

    Installation Electrical Connection Circuit Breakers The PDU is equipped with a circuit breaker for each power phase. If one phase shorts or overloads, one or both of the circuit breakers in the PDU may trip. Unplug the PDU before trying to locate and correct the electrical problem, then reset both circuit breakers on the PDU to restore power to the rack.
  • Page 10 Technical information in this document is subject to change without notice. © Copyright Hewlett-Packard Company 2002. All Rights Reserved. Reproductions, adaptations, or translation without prior written permission is prohibited, except as allowed under the copyright laws. November, 2002 Document Part Number: 5981-1470EN...