Operating and installation instructions
Cooker hood
DA 3560
DA 3590
DA 3560 EXT
DA 3590 EXT
en - GB
To avoid the risk of accidents
or damage to this appliance,
it is essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 09 466 100

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 3560

  • Page 1 Operating and installation instructions Cooker hood DA 3560 DA 3590 DA 3560 EXT DA 3590 EXT en - GB To avoid the risk of accidents or damage to this appliance, it is essential to read these instructions before it is installed and used for the first time.
  • Page 2: Table Of Contents

    Miele|home ........
  • Page 3: Caring For The Environment

    Caring for the environment Disposal of the packing material Disposal of your old appliance The transport and protective packing Electrical and electronic appliances has been selected from materials which often contain materials which, if are environmentally friendly for handled or disposed of incorrectly, disposal, and should be recycled.
  • Page 4: Warning And Safety Instructions

    Any other usage is not supported by This appliance complies with all the manufacturer and could be relevant local and national safety dangerous. Miele cannot be held liable requirements. Inappropriate use for damage resulting from incorrect or can, however, lead to personal injury improper use or operation of the and damage to property.
  • Page 5: Technical Safety

    Technical safety Installation, maintenance and repairs may only be carried out by a Before installation, check the cooker Miele authorised person in accordance hood for visible signs of damage. with current national and local safety Under no circumstances should you regulations.
  • Page 6 These models may only be combined with a Miele external motor. This appliance must not be used in a non-stationary location (e.g. on a ship).
  • Page 7 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room.
  • Page 8: Correct Use

    Warning and Safety instructions Correct use The cooker hood can get very hot during cooking due to heat rising from Never use an open flame beneath the hob. the cooker hood. To avoid the danger Do not touch the housing or the grease of fire, do not flambé...
  • Page 9 Warning and Safety instructions All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 10: Guide To The Appliance

    Guide to the appliance...
  • Page 11 Guide to the appliance Pull-out deflector plate Hob lighting button Controls This button can be used to switch the hob lighting on and off and is also a Grease filters dimmer switch. Hob lighting On/Off button for the fan Exhaust socket C 150 mm Buttons for selecting the fan The exhaust socket can also be fitted at power level...
  • Page 12: Description Of The Functions

    The charcoal filters are available to socket of the motor unit. order through your Dealer or Miele (see back page for contact details and Having a non-return flap fitted in the Technical data for part number).
  • Page 13: Miele|Home

    If the deflector plate remains pulled out, hood to be automatically controlled by the cooker hood will switch on the operating status of a Miele electric automatically the next time the hob is hob with onset controls. switched on.
  • Page 14: Operation

    Operation To switch the fan on Automatic switch-off of the Intensive setting You can set the Intensive setting so that it always only runs for 10 minutes before reverting automatically to level 3. ^ Pull the deflector plate out and switch off the fan K and the lighting I.
  • Page 15: Run-On Option 5 ¢15

    Operation Run-on option 5 ¢15 Hob lighting I It is advisable to run the fan for a few To switch the hob lighting on minutes after cooking has finished to ^ Pull the deflector plate out. neutralise any lingering odours in the air, whether you are using air extraction or recirculation mode.
  • Page 16: Filter Operating Hours Counter

    Operation Safety switch-off If you use very little fat for cooking, select a longer time of 40 or 50 hours. Should the cooker hood be left on, the fan will switch off automatically after 10 To alter the operating time: hours.
  • Page 17 Operation Activating and altering the charcoal Checking the filter operating hours filter operating hours counter — counter (with recirculation mode) To check the percentage of time set already used: The charcoal filters must be fitted for ^ Switch the fan on with the On/Off the cooker hood to be used in button K.
  • Page 18: Cleaning And Care

    The surfaces and controls are packaging. susceptible to scratches and abrasion. Please observe the To help prevent re-soiling, Miele following cleaning instructions. conditioning agent for stainless steel can also be used. Follow the ^ All external surfaces and controls can instructions on the packaging.
  • Page 19: Grease Filters

    Cleaning and care Grease filters Controls The re-usable metal grease filters in the The controls may suffer appliance remove solid particles discolouration or damage if soiling is (grease, dust, etc.) from the kitchen left on them for too long. Remove vapours, preventing soiling of the soiling straight away.
  • Page 20: Resetting The Grease Filter Operating Hours Counter

    ^ Select a programme with a maximum ^ Press the operating hours button [— temperature of 65° C. If a Miele dishwasher is being used, select the for approx. 6 seconds until only the 1 Sensor wash programme.
  • Page 21: Fitting And Replacing The Charcoal Filters

    – the Charcoal filter symbol — of the odours operating hours button lights up, Charcoal filters can be obtained from your Dealer or Miele. – they are no longer effective at See back cover for contact details, absorbing kitchen odours.
  • Page 22: Changing A Halogen Lamp

    Cleaning and care Changing a halogen lamp ^ Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Exercise caution when changing halogen lamps. They get very hot during use and remain hot for some time after being switched off. Let them cool down before you change them.
  • Page 23: After Sales Service

    For information on the appliance under guarantee, please contact: guarantee specific to your country – Your Miele Dealer / Chartered Agent please contact Miele. See back cover for contact details. In the U.K. your appliance is –...
  • Page 24: Appliance Dimensions

    Appliance dimensions...
  • Page 25 Appliance dimensions 1) Air extraction and recirculation mode Safety distance between hob and with conversion kit DUU 150 if the air is cooker hood (S) to be directed upwards out of the wall unit. The following distance must be maintained between the top of the 2) Trim the wall unit carcase so that it is cooker/hob and the bottom of the 38 mm shorter than the wall unit door.
  • Page 26: Installation

    Installation Installation accessories...
  • Page 27 Installation 1 exhaust socket for exhaust ducting C 150 mm. 1 reducing collar 4 screws M4 x 16 mm for exhaust ducting C125 mm. for securing the cooker hood to the brackets and for securing the spacer 1 non-return valve strip.
  • Page 28 Installation ^ Turn the motor unit towards the rear Before installation, it is important and position the exhaust socket in to read the information given on the the exhaust vent on the back panel of following pages as well as the the cooker hood housing.
  • Page 29 Installation...
  • Page 30 Installation ^ Pull the grease filters out of the slots ^ Screw the spacer strip to the back of in the front of the cooker hood the cooker hood at the required housing. position. Use the screws supplied. To attach The spacer strip needs to be attached the spacer strip to the lower edge to the back of the cooker hood housing...
  • Page 31 Installation ^ Screw the brackets onto the right and left inside walls of the housing unit so that they are flush with the bottom edge of the wall unit. The brackets are designed for 16 and 19 mm thick carcase sides. Orientate the bracket so that the vertical depth matches the thickness of the carcase side, as shown.
  • Page 32 Installation ^ Tighten the four securing screws from below. ^ Fit the cooker hood into the wall unit from below, guiding it over the safety notch, as shown. Push it back until the spacer strip is flush with the wall. ^ When fitting a 900 mm wide cooker hood in a 600 mm wide wall unit, insert the two rear screws at this...
  • Page 33 Installation When fitting the DA 3590 in a 900 mm If the screws are difficult to access use wide housing unit, the retaining the angled key supplied to tighten brackets supplied are used to align the them. cooker hood and provide additional ^ Unscrew the appropriate housing support.
  • Page 34: Adjusting The Deflector Plate

    Installation Adjusting the deflector plate (DA 3560, DA 3590) When retracted, the deflector plate is held in place by magnets. The retaining force of the magnets can be adjusted. The magnets should be adjusted so that the deflector plate is held in place securely on the left and right hand side and can be lowered slightly.
  • Page 35: Exhaust Connection

    Installation ^ Take the grease filters out and remove any protective foil. Replace ^ Secure the spacer strip to the bottom the grease filters. of the wall unit as well. Exhaust connection ^ Insert the non-return flap, if required. Make sure that it opens easily and closes again by itself.
  • Page 36: Setting Up For Recirculation Mode

    A conversion kit, available through your dealer or from Miele is required for operating the cooker hood in recirculation mode. You will also need two charcoal filters (see "Technical data").
  • Page 37 Installation ^ Fit the conversion kit as described in the installation instructions supplied with the kit. ^ Make sure that the slats in the exhaust grille point towards the centre of the room and not towards a wall or the ceiling. A non-return flap is not used in recirculation mode.
  • Page 38: Connection For Air Extraction

    Connection for air extraction – Only use smooth pipes or flexible Important: To avoid the danger of hoses made from non-flammable toxic fumes, please observe the materials for the extraction ducting. Warning and Safety instructions. – When using an external motor, make This is especially crucial when using sure that the exhaust ducting is the cooker hood at the same time as...
  • Page 39: Condensate Trap

    Connection for air extraction Condensate trap – If the exhaust air is to be ducted into the open air, the installation of a (optional accessory) telescopic wall vent or roof vent (available as an optional accessory) is recommended. – If the exhaust air is to be ducted into a vent flue, the ducting must be directed in the flow direction of the flue.
  • Page 40: Silencer

    Connection for air extraction Silencer ...with air extraction: (optional accessory) The silencer not only reduces noise from the fan, but also sounds from outside (e.g. traffic noise). For this reason the silencer must be positioned as close as possible to the ducting exit ...in recirculation mode: The silencer needs to be positioned...
  • Page 41: Electrical Connection

    Electrical connection If the switch is not accessible after All electrical work should be installation (depending on country), an undertaken by a suitably qualified additional means of disconnection must and competent person in strict be provided for all poles. accordance with current national For extra safety it is advisable to protect and local safety regulations the appliance with a suitable residual...
  • Page 42: Operation With Control Module Dsm 400

    Operation with Control module DSM 400 The Miele DSM 400 control module Components used in the central (optional accessory) can be used to ducting system are not supplied by combine the cooker hood with other Miele. components. If in any doubt, the advice of a...
  • Page 43: Technical Data

    Intensive setting ... 550 m DA 3560 ....15 kg DA 3560 EXT ....13 kg Special accessories for recirculation DA 3590 .