1. Before removing Microwave Drawer, take measures to protect
the Drawer louver by either removing the louver or by letting
the louver over hang off flat protected surface (Fig 1).
. Open the Drawer to access the 4 mounting screws holding the
unit on to the wall or cabinet opening. (Fig 1).
3. Close Drawer and carefully pull the unit out from opening and
unplug the power supply cord.
4. Remove top cover. (Fig 2).
5. Remove air cover from back of unit, then both side panels. (Fig 2).
6. Remove exhaust duct and back cover. (Fig 2).
NOTE: You now have access to various components for the Drawer.

MICROWAVE DRAWER DISASSEMBLY

Fig. 1
Fig. 2
Exhaust duct
Back cover
Left side panel
7
screws
Top plate
Right side panel
Air cover
Cavity
KB-6014LS
KB-6014LK
KB-6014LW
x2