Dell POWEREDGE R410 Technical Manualbook

Dell POWEREDGE R410 Technical Manualbook

Entry 2-socket 1u rack server
Hide thumbs Also See for POWEREDGE R410:
Table of Contents

Advertisement

PowerEdge R410 Technical Guidebook
DELL
TM
POWEREDGE
TECHNICAL GUIDEBOOK
INSIDE THE POWEREDGE R410
Dell
R410
TM

Advertisement

Table of Contents
loading

Summary of Contents for Dell POWEREDGE R410

  • Page 1 PowerEdge R410 Technical Guidebook DELL POWEREDGE R410 TECHNICAL GUIDEBOOK INSIDE THE POWEREDGE R410 Dell...
  • Page 2: Table Of Contents

    PowerEdge R410 Technical Guidebook Table of Contents Product Comparison........................1 Overview ..........................1 New Technologies ........................3 Overview ..........................3 System Overview ........................3 Overview ..........................3 Product Features Summary ....................3 Mechanical ..........................7 Chassis Description ......................7 Dimensions and Weight ....................... 7 Front Panel View and Features ....................
  • Page 3 PowerEdge R410 Technical Guidebook Memory ............................ 24 Overview ..........................24 DIMMs Supported ......................24 Slots/Risers ........................24 Mirroring ..........................25 Chipset ............................. 26 10.1 Overview ..........................26 BIOS ............................26 11.1 Overview ..........................26 11.2 Supported ACPI States ...................... 27 11.3...
  • Page 4 PowerEdge R410 Technical Guidebook 20.3 Embedded Server Management ..................40 20.4 Lifecycle Controller and Unified Server Configurator ............40 20.5 iDRAC Express ........................41 20.6 iDRAC6 Enterprise ......................41 Peripherals ..........................43 21.1 USB Peripherals......................... 43 21.2 External Storage ........................ 43 Packaging Options ........................
  • Page 5: Product Comparison

    1 Product Comparison 1.1 Overview The PowerEdge R410 is Dell’s entry 2-socket 1U rack server that supports the latest Intel chipset and processors. With the new Intel architecture, the memory controller is built in the processor and each processor in PowerEdge R410 supports 4 DIMMs. If two processors are installed, it supports 8 DIMMs max.
  • Page 6 PowerEdge R410 Technical Guidebook R610 Feature/Spec R410 SC1435 (Predecessors) (Next level up) Hot-swap HDD; Hot-swap HDD; Redundant PSU; LCD Redundant PSU; Quad- Tool-less chassis; quad- diagnostic; Memory Availability pack LED diagnostic/LCD pack LED for diagnostic mirroring or sparing; with Hot-swap HDD Internal SD card for chassis;...
  • Page 7: New Technologies

    SSD advantage (support SSD drives) 3 System Overview 3.1 Overview The PowerEdge R410 delivers the right combination of computing power and redundancy in an ultra- dense chassis. It is positioned to compete against HP’s DL160/DL165, and IBM’s x3450/x3455. The PowerEdge R410 provides: •...
  • Page 8 PowerEdge R410 Technical Guidebook Features Descriptions Two GbE (5716 dual port) without TOE Management Full Open Manage BMC, IPMI2.0 compliant Optional: iDRAC6-Express, iDRAC6-Enterprice and Vflash Two front/two rear/two internal Non-Redundant, 480 W (80+ SILVER) Optional Redundant, 500 W (80+ GOLD)
  • Page 9 PowerEdge R410 Technical Guidebook Features Descriptions 600 GB 2.5"/10K (in 3.5" Bosshog) 73 GB 146 GB 300 GB HDD/SSD 2.5" (in 3.5" Bosshog) 25 GB SATA SSD 50 GB SATA SSD 100 GB SATA SSD (POST-RTS) Media Bay 1x slim ODD...
  • Page 10 SQL2008 Virtualization: VMWare ESX 3.5/ESXi 3.5 and ESX 4.0/ESXi 4.0 Hyper-V (Veridian and standalone Viridian) Dell will not support XenServer. Citrix XenServer Enterprise (Std and Embedded) is supported by Citrix. HPCC: Microsoft HPC Server 2008 Red Hat Enterprise Linux 5 for HPC...
  • Page 11: Mechanical

    Mechanical 4.1 Chassis Description The PowerEdge R410 chassis design provides customers low-cost compute power with some hardware redundancy ability. It is a new chassis design for two incoming chassis offering cabled hard drive with LED module, and high-availability features such as hot-plug hard drives and LCD module.
  • Page 12: Front Panel View And Features

    PowerEdge R410 Technical Guidebook 4.3 Front Panel View and Features HDD_3 HDD_0 HDD_1 HDD_2 Figure 2. Hot-Swap HDD view Figure 3. Cabled HDD View Figure 4. With Bezel View ○ ○ ○ ○ ○ ○ ○ ○ HDD_0 HDD_1 Figure 5.
  • Page 13: Power Supply Indicators

    PowerEdge R410 Technical Guidebook Figure 7. With Non-redundant Power Supply ○ ○ ○ ○ ○ ○ ○ ○ Figure 8. Rear Panel Connectors and LEDs Rear I/O ports: layout follows 11G family look. Active ID CMA Jack System ID button...
  • Page 14: Nic Indicators

    PowerEdge R410 Technical Guidebook 4.6 NIC Indicators Figure 10. Dual-Stacked RJ45 Connectors Table 5. LED States State Link LED Activity LED (Green) (Green/Yellow) No link D0uninitalized (out of WOL disabled box), D3cold, S4 WOL enabled, link, no Green if the port is...
  • Page 15: Rails And Cable Management

    Support for low cost static rails Support sliding rails Support for tool-less installation in CEA-310-E compliant square hole 4-post racks Including Support for Dell 2410 24U Rack Support for Dell 4210 Rack Support for HP/Compaq 10xxx series Support for tooled or tool-less installation in CEA-310-E...
  • Page 16: Control Panel/Lcd

    PowerEdge R410 Technical Guidebook Figure 13. R410 Fans 4.10 Control Panel/LCD • Front control panel • LCD Status Description Internal USB connector LCD module and cable/connector Figure 14. Front Controller Board with LCD Dell...
  • Page 17: Cover Latch

    PowerEdge R410 Technical Guidebook LED module No cable and Figure 15. Front Controller Board with LEDSecurity 4.10.1 Cover Latch Cover Latch Figure 16. Cover Latch 4.10.2 Bezel Figure 17. Bezel Dell...
  • Page 18: Hard Drive

    PowerEdge R410 Technical Guidebook 4.10.3 Hard Drive Require bezel to avoid removing HDDs. 4.10.4 Trusted Platform Management (TPM) Chip Socket Location Figure 18. TPM Module Location on the Motherboard 4.10.5 Power-Off Security The control panel is designed so that the power switch cannot be accidentally activated. The lock on the bezel secures the switch behind the bezel.
  • Page 19: Secure Mode

    NMI switches on the control panel or set up a system password. See the BIOS specification in the HOM. 4.11 USB Key Dell does not offer USB keys for factory installation. 4.12 Battery Battery for the motherboard: CR2032 Figure 20. Battery Holder for PERC 6/i Figure 21.
  • Page 20: Electrical

    Configuration option information (pertinent to options such as microprocessors, system memory, remote access controllers, and storage controllers) is available separately. The NV components present in the PowerEdge R410 server are discussed further in Error! Reference source not found.. 5.2 ePPID The ePPID is an electronic repository for information from the PPID label stored in non-volatile RAM.
  • Page 21: Power, Thermal, Acoustic

    6 Power, Thermal, Acoustic 6.1 Power Supplies The R410 is powered by a non-redundant 480 W power supply (Dell P/N F238K) and redundant 500 W power supply (Dell P/N F649J). The power supply has automatic input voltage detection. An auxiliary power-out receptacle is not provided on this unit.
  • Page 22 PowerEdge R410 Technical Guidebook Figure 22. Power Supply Connector (24 pins) Table 9. Power Supply Connector (24 pins) Signals SIGNAL SIGNAL P3V3 P3V3 P3V3 P12VC P12VC P12VC PS_ENABLE_CPLD_N P12VE P12VE PS_PWROK SINGLE_PS_PRES_N P12VD P5V_AUX P12VD Figure 23. Power Supply Connector (8 pins) Table 10.
  • Page 23: Environmental Specifications

    PowerEdge R410 Technical Guidebook 6.3 Environmental Specifications Table 11. Operating/Non-operating Storage Requirements Non-Operating Operating Requirements Requirements Temperature Ranges 10 to 35 °C (For Altitude ≤900 m or 2952.75 ft) (50 to 95 °F) -40 to 65 °C (-40 to 149 °F)
  • Page 24: Acoustics

    PowerEdge R410 Technical Guidebook 6.5 Acoustics The PowerEdge R410 has balanced acoustic and thermal performance. Thermal has to support a fully- configured system with Intel 5500-EP 95 W processor. The acoustic goal is driving to meet Dell Acoustic spec AC0142 Rev.A02 category II-D requirement.
  • Page 25: Block Diagram

    PowerEdge R410 Technical Guidebook 7 Block Diagram Intel 5500 Intel 5500 Intel X58 – 24D Figure 24. R410 Motherboard Block Diagram Figure 25. Front IO Board Block Diagram Dell...
  • Page 26: Processors

    Figure 27. Hard Drive Backplane Board Block Diagram 8 Processors 8.1 Overview The PowerEdge R410 supports the Intel Xeon 5500 series processors originally released to the industry on March 30, 2009. 8.2 Supported Processors Supported Intel Xeon 5500 series processors: •...
  • Page 27: Processor Configurations

    PowerEdge R410 Technical Guidebook • X5550, 2.66G Hz/8M,4C 95W • E5540, 2.53G Hz/8M,4C 80W • E5530, 2.40G Hz/8M,4C 80W • L5520, 2.26G Hz/8M,4C 60W • L5506, 2.13G Hz/4M,4C 60W • E5520, 2.26G Hz/8M,4C 80W • E5506, 2.13G Hz/4M,4C 80W •...
  • Page 28: Processor Installation

    8 GB, DDR3 RDIMM, 1066 with ECC 9.3 Slots/Risers The PowerEdge R410 planar provides four 72-bit (240-pin) sockets for DIMM memory modules. These modules are DDR3-800/1066/1333 registered DDR SDRAM DIMMs. The modules are configured as 72-bits wide to provide for ECC. The memory controller in the CPU performs the ECC. The PowerEdge R410 planar supports a minimum of 1 GB upgradable to 64 GB of RAM, using the DIMM sizes: •...
  • Page 29: Mirroring

    PowerEdge R410 Technical Guidebook Figure 28. DIMM Installation Specifications CPU 2 DIMM x4 CPU 1 DIMM x4 Figure 29. DIMM Installation View 9.4 Mirroring In mirroring mode, the R410 must have identical memory configuration in Channel_0 and Channel_1, but must not have memory in Channel_3. When mirroring mode is enabled, usable memory capacity is half of the physical memory installed.
  • Page 30: Chipset

    SATA – 6 channels (via ICH10R) Max of one SATA drive (300 MB/s) Gen-2 on each channel 11 BIOS 11.1 Overview The R410/T410 BIOS is based on the Dell BIOS core, and supports the following features: • Intel 5500-EP Two-Socket Support •...
  • Page 31: Supported Acpi States

    12 Embedded NICs/LAN on Motherboard (LOM) 12.1 Overview There is BROADCOM 5716 chip on the PowerEdge R410 motherboard. The 5716 chip is connected to the IOH via a PCI Express x4 gen2 link. The chip provides a two-gigabit Ethernet port. There are two RJ-45 connectors with integrated magnetic on the rear of the system.
  • Page 32: O Slots

    PowerEdge R410 Technical Guidebook LOM chip: Broadcom 5716 dual port GbE Figure 30. Embedded NICs/LAN on Motherboard 13 I/O Slots 13.1 Overview with Description Table 16. Insert I/O Slot information PCI Slot # Mechanical Electrical Height Length 1 (Gen2) PCIe x16...
  • Page 33: Boot Order

    PowerEdge R410 Technical Guidebook Category Description Bandwidth Slot Priority Quantity Intel PRO/1000 PT Server Adapter 2, 1, 3, 4 Broadcom NetXtreme II 5709 Dual Port 2, 1, 3, 4 Ethernet PCIe Card with TOE 1G NICs Broadcom NetXtreme II 5709 Dual Port...
  • Page 34 PowerEdge R410 Technical Guidebook Figure 32. Hot-Swap HDD Carrier Chassis View Figure 33. Hot-Swap HDD Configuration with Backplane Figure 34. Top-View for Hot-Swap HDD Connection Dell...
  • Page 35: Drives

    PowerEdge R410 Technical Guidebook Figure 35. Top-View for Cabled HDD Connection Figure 36. Cabled HDD Connectors 14.2 Drives Refer to Section 3.2 “Product Features Summary” for supported type and capacities. 14.3 RAID Configurations Table 18. RAID Configurations Cabled/Hot Configuration Configurations...
  • Page 36 PowerEdge R410 Technical Guidebook Cabled/Hot Configuration Configurations Description Swap Type Add-in SAS/SATA SAS/SATA – W976 Cabled ASSCBL RAID card, No RAID NO RAID (SAS 6/iR) Add-in SAS/SATA SAS/SATA – Y333 Cabled ASSR0CBL RAID card, RAID 0 RAID0 (SAS 6/iR or PERC 6/i) Add-in SAS/SATA SAS/SATA –...
  • Page 37: Storage Controllers

    PowerEdge R410 Technical Guidebook Cabled/Hot Configuration Configurations Description Swap Type Mix SAS and Add-in SAS/SATA 2xSAS + 2xSAS + Hot-Swap SATA – No ASS-X RAID card, No RAID W980M 1xSATA 2xSATA RAID (SAS 6/iR) Mix SAS and Add-in SAS/SATA SATA –...
  • Page 38: Video

    PowerEdge R410 Technical Guidebook Video 15.1 Overview Matrox G200eW with 8 MB memory integrated in Windbond WPCM450 (BMC controller) • 1280x1024 at 85 Hz for KVM and 1600x1200 at 60 Hz for video out 640x480 (60/72/75/85 Hz; 8/16/32-bit color) 800x600 (60/72/75/85 Hz; 8/16/32-bit color) 1024x768 (60/72/75/85 Hz;...
  • Page 39: Slide Rails

    Support for Dell Clydesdale Racks (4220, 2420) Support for Dell R2K Racks (4210, 2410) Support for Dell Marconi Racks (4200, 2400) with louvered rear door Support for HP/Compaq 10xxx series racks Support for HP/Compaq 7xxx and 9xxx series racks without the CMA •...
  • Page 40: Cable Management Arm (Cma)

    • Round-hole rack adjustment range: 594-872 mm • Threaded-hole rack adjustment range: 604-890 mm 17.2 Cable Management Arm (CMA) The PowerEdge R410 uses the same CMA as R610, which supports the following cable load: • Two power • Four SAS •...
  • Page 41 PowerEdge R410 Technical Guidebook Table 20. Microsoft OS Logo/ Operating Factory Test Suppor Engineering Installation Schedule Certificati Systems Install /Validate Response Small Covered in Standard Business Server Server 2008 Premium 2008 family FI (SP2 Small Covered in Standard only) Business...
  • Page 42: Virtualization

    PowerEdge R410 Technical Guidebook Table 21. Linux OS Logo/ Operating Systems Installation Factory Install Schedule Certification Enterprise Server (ES) x86-64 Advance Server (AS) Red Hat Enterprise Linux x86-64 POST_RTS (CY09 Q2 DIB, NFI block) Enterprise Server (ES) x86-32 Advance Server (AS)
  • Page 43: Systems Management

    20 Systems Management 20.1 Overview/Description Dell aims on delivering open, flexible, and integrated solutions that help you reduce the complexity of managing disparate IT assets by building comprehensive IT management solutions. Combining Dell PowerEdge Servers with a wide selection of Dell-developed management solutions gives you choice and flexibility, so you can simplify and save in environments of any size.
  • Page 44: Embedded Server Management

    For servers without iDRAC Express, this utility has limited functionality and offers OS install and diagnostics capabilities only. To access the Unified Server Configurator, press the <F10> key within 10 seconds of the Dell logo’s appearance during the system boot process. Current functionality enabled by the Unified Server Configurator includes: Table 23.
  • Page 45: Idrac Express

    Additionally, the iDRAC6 Enterprise can be upgraded by adding the vFlash Media card. This is a 1 GB Dell branded SD card that enables a persistent 256 MB virtual flash partition. In the future, vFlash will be expanded to include additional features.
  • Page 46 PowerEdge R410 Technical Guidebook Feature iDRAC 6 Express iDRAC6 Enterprise vFlash Media    IPv6    Dynamic DNS   Dedicated NIC Security and Authentication     Role-based Authority     Local Users ...
  • Page 47: Peripherals

    PowerEdge R410 Technical Guidebook 21 Peripherals 21.1 USB Peripherals Optional USB 1.44 MB floppy drive Optional USB DVD-ROM 21.2 External Storage Refer to Section 3.2 “Product Features Summary”. 22 Packaging Options • Options for single pack and multipack are available.
  • Page 48 PowerEdge R410 Technical Guidebook Appendix A. R410 Volatility Chart Table 25. R410 Volatility Table Backplane Firmware and FRU Size 32 KB Type Flash Can user programs or operating system write data to it during normal operation? Purpose Backplane Firmware and FRU data storage...

Table of Contents