1 Product Comparison 1.1 Overview The PowerEdge R410 is Dell’s entry 2-socket 1U rack server that supports the latest Intel chipset and processors. With the new Intel architecture, the memory controller is built in the processor and each processor in PowerEdge R410 supports 4 DIMMs. If two processors are installed, it supports 8 DIMMs max.
Page 6
PowerEdge R410 Technical Guidebook R610 Feature/Spec R410 SC1435 (Predecessors) (Next level up) Hot-swap HDD; Hot-swap HDD; Redundant PSU; LCD Redundant PSU; Quad- Tool-less chassis; quad- diagnostic; Memory Availability pack LED diagnostic/LCD pack LED for diagnostic mirroring or sparing; with Hot-swap HDD Internal SD card for chassis;...
SSD advantage (support SSD drives) 3 System Overview 3.1 Overview The PowerEdge R410 delivers the right combination of computing power and redundancy in an ultra- dense chassis. It is positioned to compete against HP’s DL160/DL165, and IBM’s x3450/x3455. The PowerEdge R410 provides: •...
Page 8
PowerEdge R410 Technical Guidebook Features Descriptions Two GbE (5716 dual port) without TOE Management Full Open Manage BMC, IPMI2.0 compliant Optional: iDRAC6-Express, iDRAC6-Enterprice and Vflash Two front/two rear/two internal Non-Redundant, 480 W (80+ SILVER) Optional Redundant, 500 W (80+ GOLD)
Page 9
PowerEdge R410 Technical Guidebook Features Descriptions 600 GB 2.5"/10K (in 3.5" Bosshog) 73 GB 146 GB 300 GB HDD/SSD 2.5" (in 3.5" Bosshog) 25 GB SATA SSD 50 GB SATA SSD 100 GB SATA SSD (POST-RTS) Media Bay 1x slim ODD...
Page 10
SQL2008 Virtualization: VMWare ESX 3.5/ESXi 3.5 and ESX 4.0/ESXi 4.0 Hyper-V (Veridian and standalone Viridian) Dell will not support XenServer. Citrix XenServer Enterprise (Std and Embedded) is supported by Citrix. HPCC: Microsoft HPC Server 2008 Red Hat Enterprise Linux 5 for HPC...
Mechanical 4.1 Chassis Description The PowerEdge R410 chassis design provides customers low-cost compute power with some hardware redundancy ability. It is a new chassis design for two incoming chassis offering cabled hard drive with LED module, and high-availability features such as hot-plug hard drives and LCD module.
PowerEdge R410 Technical Guidebook Figure 7. With Non-redundant Power Supply ○ ○ ○ ○ ○ ○ ○ ○ Figure 8. Rear Panel Connectors and LEDs Rear I/O ports: layout follows 11G family look. Active ID CMA Jack System ID button...
PowerEdge R410 Technical Guidebook 4.6 NIC Indicators Figure 10. Dual-Stacked RJ45 Connectors Table 5. LED States State Link LED Activity LED (Green) (Green/Yellow) No link D0uninitalized (out of WOL disabled box), D3cold, S4 WOL enabled, link, no Green if the port is...
Support for low cost static rails Support sliding rails Support for tool-less installation in CEA-310-E compliant square hole 4-post racks Including Support for Dell 2410 24U Rack Support for Dell 4210 Rack Support for HP/Compaq 10xxx series Support for tooled or tool-less installation in CEA-310-E...
PowerEdge R410 Technical Guidebook Figure 13. R410 Fans 4.10 Control Panel/LCD • Front control panel • LCD Status Description Internal USB connector LCD module and cable/connector Figure 14. Front Controller Board with LCD Dell...
PowerEdge R410 Technical Guidebook 4.10.3 Hard Drive Require bezel to avoid removing HDDs. 4.10.4 Trusted Platform Management (TPM) Chip Socket Location Figure 18. TPM Module Location on the Motherboard 4.10.5 Power-Off Security The control panel is designed so that the power switch cannot be accidentally activated. The lock on the bezel secures the switch behind the bezel.
NMI switches on the control panel or set up a system password. See the BIOS specification in the HOM. 4.11 USB Key Dell does not offer USB keys for factory installation. 4.12 Battery Battery for the motherboard: CR2032 Figure 20. Battery Holder for PERC 6/i Figure 21.
Configuration option information (pertinent to options such as microprocessors, system memory, remote access controllers, and storage controllers) is available separately. The NV components present in the PowerEdge R410 server are discussed further in Error! Reference source not found.. 5.2 ePPID The ePPID is an electronic repository for information from the PPID label stored in non-volatile RAM.
6 Power, Thermal, Acoustic 6.1 Power Supplies The R410 is powered by a non-redundant 480 W power supply (Dell P/N F238K) and redundant 500 W power supply (Dell P/N F649J). The power supply has automatic input voltage detection. An auxiliary power-out receptacle is not provided on this unit.
Page 22
PowerEdge R410 Technical Guidebook Figure 22. Power Supply Connector (24 pins) Table 9. Power Supply Connector (24 pins) Signals SIGNAL SIGNAL P3V3 P3V3 P3V3 P12VC P12VC P12VC PS_ENABLE_CPLD_N P12VE P12VE PS_PWROK SINGLE_PS_PRES_N P12VD P5V_AUX P12VD Figure 23. Power Supply Connector (8 pins) Table 10.
PowerEdge R410 Technical Guidebook 6.3 Environmental Specifications Table 11. Operating/Non-operating Storage Requirements Non-Operating Operating Requirements Requirements Temperature Ranges 10 to 35 °C (For Altitude ≤900 m or 2952.75 ft) (50 to 95 °F) -40 to 65 °C (-40 to 149 °F)
PowerEdge R410 Technical Guidebook 6.5 Acoustics The PowerEdge R410 has balanced acoustic and thermal performance. Thermal has to support a fully- configured system with Intel 5500-EP 95 W processor. The acoustic goal is driving to meet Dell Acoustic spec AC0142 Rev.A02 category II-D requirement.
Figure 27. Hard Drive Backplane Board Block Diagram 8 Processors 8.1 Overview The PowerEdge R410 supports the Intel Xeon 5500 series processors originally released to the industry on March 30, 2009. 8.2 Supported Processors Supported Intel Xeon 5500 series processors: •...
8 GB, DDR3 RDIMM, 1066 with ECC 9.3 Slots/Risers The PowerEdge R410 planar provides four 72-bit (240-pin) sockets for DIMM memory modules. These modules are DDR3-800/1066/1333 registered DDR SDRAM DIMMs. The modules are configured as 72-bits wide to provide for ECC. The memory controller in the CPU performs the ECC. The PowerEdge R410 planar supports a minimum of 1 GB upgradable to 64 GB of RAM, using the DIMM sizes: •...
PowerEdge R410 Technical Guidebook Figure 28. DIMM Installation Specifications CPU 2 DIMM x4 CPU 1 DIMM x4 Figure 29. DIMM Installation View 9.4 Mirroring In mirroring mode, the R410 must have identical memory configuration in Channel_0 and Channel_1, but must not have memory in Channel_3. When mirroring mode is enabled, usable memory capacity is half of the physical memory installed.
SATA – 6 channels (via ICH10R) Max of one SATA drive (300 MB/s) Gen-2 on each channel 11 BIOS 11.1 Overview The R410/T410 BIOS is based on the Dell BIOS core, and supports the following features: • Intel 5500-EP Two-Socket Support •...
12 Embedded NICs/LAN on Motherboard (LOM) 12.1 Overview There is BROADCOM 5716 chip on the PowerEdge R410 motherboard. The 5716 chip is connected to the IOH via a PCI Express x4 gen2 link. The chip provides a two-gigabit Ethernet port. There are two RJ-45 connectors with integrated magnetic on the rear of the system.
PowerEdge R410 Technical Guidebook Cabled/Hot Configuration Configurations Description Swap Type Mix SAS and Add-in SAS/SATA 2xSAS + 2xSAS + Hot-Swap SATA – No ASS-X RAID card, No RAID W980M 1xSATA 2xSATA RAID (SAS 6/iR) Mix SAS and Add-in SAS/SATA SATA –...
PowerEdge R410 Technical Guidebook Video 15.1 Overview Matrox G200eW with 8 MB memory integrated in Windbond WPCM450 (BMC controller) • 1280x1024 at 85 Hz for KVM and 1600x1200 at 60 Hz for video out 640x480 (60/72/75/85 Hz; 8/16/32-bit color) 800x600 (60/72/75/85 Hz; 8/16/32-bit color) 1024x768 (60/72/75/85 Hz;...
Support for Dell Clydesdale Racks (4220, 2420) Support for Dell R2K Racks (4210, 2410) Support for Dell Marconi Racks (4200, 2400) with louvered rear door Support for HP/Compaq 10xxx series racks Support for HP/Compaq 7xxx and 9xxx series racks without the CMA •...
• Round-hole rack adjustment range: 594-872 mm • Threaded-hole rack adjustment range: 604-890 mm 17.2 Cable Management Arm (CMA) The PowerEdge R410 uses the same CMA as R610, which supports the following cable load: • Two power • Four SAS •...
Page 41
PowerEdge R410 Technical Guidebook Table 20. Microsoft OS Logo/ Operating Factory Test Suppor Engineering Installation Schedule Certificati Systems Install /Validate Response Small Covered in Standard Business Server Server 2008 Premium 2008 family FI (SP2 Small Covered in Standard only) Business...
PowerEdge R410 Technical Guidebook Table 21. Linux OS Logo/ Operating Systems Installation Factory Install Schedule Certification Enterprise Server (ES) x86-64 Advance Server (AS) Red Hat Enterprise Linux x86-64 POST_RTS (CY09 Q2 DIB, NFI block) Enterprise Server (ES) x86-32 Advance Server (AS)
20 Systems Management 20.1 Overview/Description Dell aims on delivering open, flexible, and integrated solutions that help you reduce the complexity of managing disparate IT assets by building comprehensive IT management solutions. Combining Dell PowerEdge Servers with a wide selection of Dell-developed management solutions gives you choice and flexibility, so you can simplify and save in environments of any size.
For servers without iDRAC Express, this utility has limited functionality and offers OS install and diagnostics capabilities only. To access the Unified Server Configurator, press the <F10> key within 10 seconds of the Dell logo’s appearance during the system boot process. Current functionality enabled by the Unified Server Configurator includes: Table 23.
Additionally, the iDRAC6 Enterprise can be upgraded by adding the vFlash Media card. This is a 1 GB Dell branded SD card that enables a persistent 256 MB virtual flash partition. In the future, vFlash will be expanded to include additional features.
Page 46
PowerEdge R410 Technical Guidebook Feature iDRAC 6 Express iDRAC6 Enterprise vFlash Media IPv6 Dynamic DNS Dedicated NIC Security and Authentication Role-based Authority Local Users ...
PowerEdge R410 Technical Guidebook 21 Peripherals 21.1 USB Peripherals Optional USB 1.44 MB floppy drive Optional USB DVD-ROM 21.2 External Storage Refer to Section 3.2 “Product Features Summary”. 22 Packaging Options • Options for single pack and multipack are available.
Page 48
PowerEdge R410 Technical Guidebook Appendix A. R410 Volatility Chart Table 25. R410 Volatility Table Backplane Firmware and FRU Size 32 KB Type Flash Can user programs or operating system write data to it during normal operation? Purpose Backplane Firmware and FRU data storage...