Download Print this page

Advertisement

Quick Links

Quick Start Guide

C O P Y R I G H T © 2 0 0 7 L G E L E C T R O N I C S U S A I N C , A L L R I G H T S R E S E R V E D .
LG IrisAccess™ 4000: iCAM4100 Quick Start Guide
The content of this document is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by LG Electronics USA
Incorporated. LG Electronics USA Incorporated assumes no responsibility or liability for any errors or inaccuracies that may appear in the informational content contained in this document.
Please remember that existing images or drawings that you may want to include in your document may be protected under copyright law. The unauthorized incorporation of such material
into your work could be a violation of the rights of the copyright owner. Please be sure to obtain any permission required from the copyright owner.
LG, LG Iris, the LG logo, LG Iris logo and IrisAccess are either registered trademarks or trademarks of LG Electronics Incorporated in the United States and/or other countries.
LG Electronics USA Incorporated, Iris Technology Division. 7 Clarke Drive, Cranbury, New Jersey 08512, USA.
Document Number: DV002Q502 (07/07)
FOR MODEL NUMBERS:
iCAM4100
iCAM4100R
iCAM4101
iCAM4101R
iCAM4110-E1
iCAM4110R-E1
iCAM4110-H1
iCAM4110R-H1
iCAM4111-E1
iCAM4111R-E1
iCAM4111-H1
iCAM4111R-H1

Advertisement

loading

Summary of Contents for LG IrisAccess iCAM4100

  • Page 1: Quick Start Guide

    LG IrisAccess™ 4000: iCAM4100 Quick Start Guide The content of this document is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by LG Electronics USA Incorporated. LG Electronics USA Incorporated assumes no responsibility or liability for any errors or inaccuracies that may appear in the informational content contained in this document.
  • Page 2: Packing List

    • Power Cable for 110V • CAT5 Ethernet Cable • Quick Start Guide • Security Screw Wrench Required Equipment (not included with iCAM4100) • Server Computer (refer to the Hardware Manual for details) • Ethernet Switch • Ethernet Wiring • Uninterruptible Power Supply...
  • Page 3 RS-422 Serial Network Switch The iCAM4100 is a two-eye iris camera used to capture the iris images of the user. The iCAM includes an alignment indicator behind the mirror and voice prompts to assist the user. A Vacuum Fluorescent Display (VFD) displays system time, date, and user guidance.
  • Page 4: Installation Requirements

    (140mm) floor • The recommended mounting height for the iCAM4100 is 140cm (55 inches) from the floor to the bottom of the unit. This mounting height can be adjusted to accommodate the average user height at the installed location. • High amounts of ambient light must be avoided. Intense light sources such as sunlight or halogen lamps may reduce the image capture performance of the iCAM, this may result in an increased “failure to acquire”...
  • Page 5 2. While gently pulling the cover upward, pull forward simultaneously. Screw to fix the plate 3. Unscrew the installation plate screw and slide the body of iCAM4100 upward to separate from the installation plate. 4. Position the installation plate on the desired wall near the secured door and mark the holes as the figure below illustrates.
  • Page 6 Installation (cont’d) <hole> 6.4801 Hole Dimensions and Screw Holes in the Installation Plate (mm unit) 62.8 35.5 Installation Plate Rotation Part with Front Enclosure Dimensions of iCAM4100 (mm unit)
  • Page 7 7. Using the appropriate fasteners for the material in which the iCAM will be mounted, secure the installation plate. 8. Slide the iCAM4100 body into the installation plate and fasten it with the retaining screw. 9. Attach the wires from the 12VDC power supply to the screw terminal connections. The +12VDC (white wire) power connects to the + (positive) terminal, whereas the 12VDC ground (black wire) connects to the –...
  • Page 8 Configuration Changing the IP Address of the iCAM * Note: The IP Address of each iCAM must be changed individually. Do not connect more than one un-configured iCAM to the network at any one time to avoid IP Address conflicts.
  • Page 9 Configuration (cont’d) 5. Select Network Settings. 6. Enter the new IP address for the iCAM (default = 192.168.5.100) 7. Enter the new Subnet Mask for the iCAM (default = 255.255.255.0) 8. Enter the new Broadcast Address for the iCAM (default = 192.168.5.255) 9.
  • Page 10 Configuration (cont’d) Once all iCAMs have been configured Once all iCAMs have been configured, the computer IP Address can then be changed back to its original IP Address or to the new IP Address as required to communicate to the rest of the IrisAccess™ system.
  • Page 11: Technical Support

    Technical Support Technical Support Additional information and Technical assistance is available on the LG Electronics – Iris Technology Division’s support web site at www.lgiris.com, click on Support & Service then Technical Support.