Normal Operation - GE Electronic Icemaker Technical Service Manual

Electronic icemaker
Table of Contents

Advertisement

While in the harvest cycle in the service mode,
the heater will remain on for a minimum of 20
seconds. The water fill cycle will initiate the
first fill (5.1 seconds) without waiting for the mold
to "prechill". Only one water fill occurs during
the service mode, whether the thermistor has
reached 39.2°F (4°C) or not. The icemaker will
exit the service diagnostic test on its own and
enter the normal freeze cycle.
NOTE: When replacing an icemaker, the Power
On test will probably occur since the mold
temperature will be above 50°F (10°C). While
in the power on test, the Service Diagnostic test
can be initiated and will override the power on
test mode.
FREEZE
CYCLE
Wait
until frozen
(
minimum 30 minutes)
(usually takes about 60 minutes)

NORMAL OPERATION

(EJECTOR STARTING AT HOME POSITION)
MOTOR ON
HEATER ON
HEATER ON
until 35.6˚F (2˚C)
(minimum 20 seconds)
MOTOR ON
3
MINUTES
5
V
PRECHILL
A
O
L
CYCLE
N
V
E
About
5.1
10 MINS.
secs.
Less than
35.6˚F (2˚C)

Hide quick links: