Item
Condition
• Med power
1) CH-SIG : 1-1
model
Select _POW_XXX
(High power)
in tune mode
PTT : ON
(Low power) 1) CH-SIG : 1-1
Select LPOW_XXX
in tune mode
PTT : ON
9. Maximum
1) Select _ _L
deviation
MXDV_XXX
• Wide
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/50mV
2) Select _ _C
MXDV_XXX
in tune mode
PTT : ON
3) Select _ _H
MXDV_XXX
in tune mode
PTT : ON
• Narrow
1) Up/down knob : Set the narrow
n_L
MXDV_XXX in tune mode
PTT : ON
2) Select n_C
MXDV_XXX
in tune mode
PTT : ON
3) Select n_H
MXDV_XXX
in tune mode
PTT : ON
10. MIC
1) CH-SIG : 1-1
sensitivity
PTT : ON
Wide only
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/5mV
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
TX-RX VR1
Ammeter
(C/3)
Panel
Power meter Rear
ANT
Panel
Deviation
meter
AF VTVM Panel
MIC
AG
Oscilloscope
TX-RX VR501 Check
(B/3)
TK-790/
Adjustment
Parts
Method
Maximum clockwise 47W or less
45W adj.
45W±1W, 12A or less
PF3 key Check
45W±1W
PF4 key
5W adj.
5W±1W
PF3 key Wide ±4.1kHz
± 0.1kHz
PF4 key
Narrow ±2.05kHz
± 0.05kHz
2.75~3.25kHz
(
B
)
/H
(
B
)
Specifications/Remarks
71