Mitsubishi Electric PLFY-P-VBM-E Operation Manual

Air-conditioners for building application indoor unit
Hide thumbs Also See for PLFY-P-VBM-E:

Advertisement

Air-Conditioners For Building Application
INDOOR UNIT
PLFY-P·VBM-E

OPERATION MANUAL

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de aircondi-
tioner gebruikt.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e
sicuro della stessa.
ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΧΡΗΣΕΩΣ
Για ασφάλεια και σωστή χρήση, παρακαλείστε διαβάσετε προσεχτικά αυτό το εγχειρίδιο χρήσεως πριν
θέσετε σε λειτουργία τη μονάδα κλιματισμού.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a
unidade de ar condicionado.
Işletme Elkitabı
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını işletmeden önce bu
elkitabını dikkatle okuyunuz.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями,
указанными в данном руководстве по эксплуатации, тщательным образом до того, как приступать к
использованию кондиционера.
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
ΓΙΑ ΤΟΝ ΧΡΗΣΤΗ
PARA O UTILIZADOR
KULLANICI İÇİN
ДЛЯ ПОЛЬЗОВАТЕЛЯ
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Ελληνικά (GR)
Português (P)
Türkçe (TR)
Русский (RU)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PLFY-P-VBM-E

  • Page 1: Operation Manual

    Air-Conditioners For Building Application INDOOR UNIT PLFY-P·VBM-E OPERATION MANUAL FOR USER English (GB) For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch (D) Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2: Table Of Contents

    2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of- life, should be disposed of separately from your household waste.
  • Page 3: Parts Names

    2. Parts Names Wired Remote-Controller “Sensor” indication Display Section Displayed when the remote controller sensor is used. Day-of-Week For purposes of this explanation, Shows the current day of the week. all parts of the display are shown. During actual operation, only the Time/Timer Display relevant items will be displayed.
  • Page 4: Screen Configuration

    2. Parts Names Indoor Unit PLFY-P . VBM-E Filter Fan steps 4 steps Air outlet Vane Auto with swing Louver – Filter Long-life Filter cleaning indication 2,500 hr Vane Air intake 3. Screen Configuration <Screen Types> For details on setting the language for the remote controller display, refer Function Selection of remote controller Set Day/Time to section 8.
  • Page 5: Fan Speed Setting

    5. Operation 5.4. Fan speed setting <To Stop Operation> Press the ON/OFF button again. Press the Fan Speed button as many times as necessary while the • The ON lamp and the display area go dark. system is running. • Each press changes the force. The currently selected speed is Note: shown at Even if you press the ON/OFF button immediately after shutting down the op-...
  • Page 6 5. Operation < How to set the fixed up/down air direction (Only for Horizontal airflow wired remote controller) > Downward • For PLFY-BM, only the particular outlet can be fixed to certain direction Fixing Remote controller setting with the procedures below. Once fixed, only the set outlet is fixed The airflow direction of The airflow direction of every time air conditioner is turned on.
  • Page 7 5. Operation < Process for setting > [1] To turn off air conditioner and change the remote [4] To cancel "Fixed airflow direction mode" to cancel "Fixed airflow direction mode".It is controller to "Fixed airflow direction mode" 1.Press ON/OFF button also canceled by pressing Fan Speed button and Filter button...
  • Page 8 5. Operation How to find air conditioner No. [2] To check by changing Address No. of indoor unit one after the other (Maximum unit No. is 50) Each air conditioner has its own Address No. of indoor unit (Example 1. Press Mode button (Return button) and Address No.
  • Page 9: Timer

    6. Timer 6.1. For Wired Remote-controller <How to Set the Weekly Timer> 1. Be sure that you are at a standard control screen, and that the weekly You can use Function Selection of remote controller to select which of timer indicator is shown in the display.
  • Page 10 6. Timer 6.1.2. Simple Timer 7. Press the appropriate Set Temperature button to set the desired temperature (at You can set the simple timer in any of three ways. • Start time only: * Each press changes the setting, in the following sequence: No dis- The air conditioner starts when the set time has elapsed.
  • Page 11 6. Timer 7. After completing steps 3 to 6 above, press the Filter button Example 2: lock in the value. Start the timer : OFF time is set earlier than ON time. Note: ON Setting : 5 hours Your new settings will be cancelled if you press the Mode (Return) button OFF Setting : 2 hours before pressing the Filter button...
  • Page 12: Other Functions

    6. Timer <Checking the Current Auto Off Timer Setting> Alternatively, turn off the air conditioner itself. The timer value (at will disappear from the screen. Timer Setting TIMER AFTER AUTO OFF 1. Be sure that the “Auto Off” is visible on the screen (at AUTO OFF <To Turn On the Auto Off Timer>...
  • Page 13: Function Selection

    7. Other Functions 7.2. Error Codes indication ERROR CODE ON lamp ON/OFF (Blinking) Error Code Unit No. If you have entered contact number to be called in the event of a problem, the screen displays this number. (You can set this up under Function Selection of remote controller. For information, refer to section 8.) If the ON lamp and error code are both flashing: This means that the air conditioner is out of order and operation has been stopped (and cannot resume).
  • Page 14 8. Function Selection [Function selection flowchart] Normal display (Display when the air conditioner is not running) Setting language (English) Hold down the button and press the button for 2 seconds. Hold down the button and press the button for 2 seconds. Press the operation mode button.
  • Page 15 8. Function Selection [Detailed setting] [4]–3. Mode selection setting (1) Remote controller main/sub setting [4]–1. CHANGE LANGUAGE setting • To switch the setting, press the [ ON/OFF] button The language that appears on the dot display can be selected. Main: The controller will be the main controller.
  • Page 16 8. Function Selection [Dot display table] Selecting language English German Spanish Russian Italian Chinese French Japanese Waiting for start-up Operation mode Cool Heat Auto Auto(Cool) Auto(Heat) Ventilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection...
  • Page 17: Care And Cleaning

    9. Care and cleaning 9.1. Cleaning the filters and the indoor unit Caution: • Ask authorized people to clean the filter. Cleaning the filters • Clean the filters using a vacuum cleaner. If you do not have a vacuum cleaner, tap the filters against a solid object to knock off dirt and dust. •...
  • Page 18: Trouble Shooting

    10. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) Air conditioner does not heat or cool well. Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit.
  • Page 19: Specifications

    10. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifications. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room.
  • Page 20 This product is designed and intended for use in the residential, commercial and light-industrial environment. Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN RG79D836H01 Printed in UNITED KINGDOM...

This manual is also suitable for:

City multi plfy-p-vbm-e

Table of Contents