Outer Tub Assembly Removal
Turn Clockwise to Loosen
Tub Outlet Hose
• Turn the Phillips-head clamp screw clockwise to loosen the clamp that
secures the tub outlet hose to the outer tub.
• Remove the tub outlet, air chamber inlet and pump air inlet hoses from
the tub.
Note: The Phillips-head clamp screw on the tub outlet hose uses reverse
rotation to tighten or loosen the hose. It is necessary to turn the Phillips
head clamp screw clockwise to loosen the clamp.
Pump Air Inlet Hose
Air Chamber Inlet Hose