The self-diagnosis function consists of error codes for customers which are displayed automatically when errors occur, and error codes which
show the error history in the test mode during servicing. For details on how to view error codes for the customer, refer to the following box
in the instruction manual. For details on how to check error codes during servicing, refer to the following "Procedure for using the Self-
Diagnosis Function (Error History Display Mode)".
The deck's self-diagnosis function automatically checks the condition of the MD deck when an error occurs, then issues a three- or five-digit
code and an error message on the display. If the code and message alternate, find them in the following table and perform the indicated
countermeasure. Should the problem persist, consult your nearest Sony dealer.
Three- or five-
digit code/
Cause/Remedy
Message
The inserted MD is record-protected.
C11/Protected
Take out the MD and close the record-
protect slot (page 15).
You tried to record a CD with a format
that the external device connected to the
deck does not support, such as CD-ROM
C12/Cannot Copy
or video CD.
Remove the disc and insert a music
CD.
The recording was not made properly.
Set the deck in a stable surface, and
repeat the recording procedure.
The inserted MD is dirty (with smudges,
C13/REC Error
fingerprints, etc.), scratched, or
substandard in quality.
Replace the disc and repeat the
recording procedure.
The deck could not read the TOC on the
MD properly.
C13/Read Error
Take out the MD and insert it again.
The deck could not read the TOC on the
MD properly.
C14/Toc Error
Insert another disc.
If possible, erase all the tracks on the
MD (page 32).
The sound source is a copy of
commercially available music software, or
you tried to record a CD-R (Recordable
CD).
C41/Cannot Copy
The Serial Copy Management System
prevents making a digital copy
(page 52). You cannot record a CD-R.
PROCEDURE FOR USING THE SELF-DIAGNOSIS FUNCTION (ERROR HISTORY DISPLAY MODE)
Note: Perform the self-diagnosis function in the "error history display mode" in the test mode. The following describes the least required procedure. Be
careful not to enter other modes by mistake. If you set other modes accidentally, press the MENU/NO button to exit the mode.
1. While pressing the l AMS L knob and x button, connect the power plug to the outlet, and release the l AMS L knob and
x button. When the test mode is set "[Check]" is displayed.
2. Turn the l AMS L knob and when "[Service]" is displayed, press the YES button.
3. Turn the l AMS L knob to display "Err Display".
4. Press the YES button to sets the error history mode and displays "op rec tm".
5. Select the contents to be displayed or executed using the l AMS L knob.
6. Press the l AMS L knob to display or execute the contents selected.
7. Press the l AMS L knob another time to return to step 4.
8. Press the MENU/NO button to display "Err Display" and release the error history mode.
9. To release the test mode, press the REPEAT button. The unit sets into the STANDBY state and the test mode ends.
4

SELF-DIAGNOSIS FUNCTION

Three- or five-
digit code/
Cause/Remedy
Message
The sporadic appearance of this message
is caused by the digital signal being
recorded. This will not affect the
recording.
While recording from a digital component
C71/Din Unlock
connected through the DIGITAL IN
connector, the digital connecting cable
was unplugged or the digital component
turned off.
Connect the cable or turn the digital
component back on.
There is an error in the internal data that
E0001/
the deck needs in order to operate.
MEMORY NG
Consult your nearest Sony dealer.
There is a problem with the optical
pickup.
E0101/
LASER NG
The optical pickup may have failed.
Consult your nearest Sony dealer.