IHOW TO DISASSEMBLE MAIN UNIT.
Ref. No. 2A
Procedure 2A
EY6405/EY6409
Procedure 2A → → → → 2B
Ref. No. 2B
Fig.4
Fig.6
Removal of the Housing.
1. Remove eight housing screws.
(See or Fig.4 or Fig.5)
EY6432
Removal or attachment of the Motor.
(Removal)
1. Take out the motor with the gear box block from housing.
2. Separate the motor from the gear box block by twisting the motor
to unlock tabs.
(Attachment)
3. Motor mounting base and the positioning rib of gear case should
be set. (See Fig.6)
4
Fig.5