1. OPERATING INSTRUCTIONS 1-1. FRONT PANEL CONTROLS 2 4 5 SCAN Fig. 2 6. Underscan/overscan select button (SCAN) 1. Speaker The initial setting is for the normal screen When the monitor selector button (A, B or Y/C) (overscan). If the SCAN button is pressed, the is pressed, the speaker lets you hear the sound screen will become smaller (underscan) than from the components which are connected to...
Page 4
1-2. REAR PANEL CONTROLS & CONNECTION Fig. 3 1. AC INPUT socket Connect the AC power cord (supplied) securely to this socket and to a wall outlet. 2. Rear A terminals (AUDIO/VIDEO A terminals) When the monitor A selector button at the front of the monitor is pressed, the audio and video signals from the component which is connected to these terminals can be monitored.
Page 5
2. SERVICE ADJUSTMENTS 1. Supply power to the set and measuring instruments and allow to warm up for at least 30 minutes. NOTE Be sure to use a non-metallic driver for adjusting there VRs. A metallic driver can cause damage by shorting. Adjustment tool 1.
Page 6
ADJUSTMENT TIMING ADJUSTMENT PROCEDURE SETTING ITEM LOCATION PATTERN VR801,VR803, Adjust VR805 G-Bias to center. BRIGHT VR , WHITE BAL- PATTERN GENERATOR VR805, Adjust FBT screen VR make luminance CONTRAST VR ANCE AD- NO SIGNAL FBT FOCUS without video to 2.0 ~ 4.0 FL. and SHARPNESS JUSTMENT Adjust VR801 make X value is 0.313 ±...
Page 9
ELECTRICAL PARTS Note: 1. Materials of Capacitors and Resistors are abbreviated as follows ; Resistors Capacitors CF RES Carbon Film Resistor MEF CAP Metallized Polyester Film Capacitor MF RES Metal Film Resistor (Non-inductive) MOF RES Metallized Oxide Film Resistor MEMB CAP Mini Box Metallized Polyester Capacitor (Non-inductive) PEI CAP...