Procedure:
Click the Event Filter Tab to configure the event filters in the available slots
1.
To Add an Event Filter entry, select a free slot and click Add to open the Add
2.
event Filter entry Page. A sample screenshot of Add Event Filter Page is in
seen the screenshot below.
3.
In the Event Filter Configuration section,
PEF ID displays the ID for configured PEF entry (read-only).
In filter configuration, check the box to enable the PEF settings.
In Event Severity, select any one of the Event severity from the list.
4.
In the Filter Action configuration section,
Event Filter Action is a mandatory field and checked by default, which enable
PEF Alert action (read-only).
Select any one of the Power action either Power down, Power reset or Power
cycle from the drop down list
Choose any one of the configured alert policy number from the drop down
list.
Alert Policy has to be configured - under Configuration->PEF->Alert Policy.
5.
In the Generator ID configuration section,
Check Generator ID Data option to fill the Generator ID with raw data.
Generator ID 1 field is used to give raw generator ID1 data value.
Generator ID 2 field is used to give raw generator ID2 data value.
In RAW data field, to specify hexadecimal value prefix with '0x'.