en | Configuration
6.6

Network

Figure 6.9: Network
Input here the following network information:
Important: The system needs to check the validity of all IPv6 addresses. The IP address and
the default gateway must be the same in each IP section (i.e. the specified length of the
subnet prefix must have the same string).
Important: The system always needs to reboot if any of the above ports are changed. Make
sure the port values here do not conflict.
2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder
IP version: IPv4 (default) or IPv6. This is the IP address access format.
DHCP (only for IPv4 option): Select this to automatically search for IP details. If this field
is enabled, you cannot modify IP / Subnet mask / Gateway and these values are displayed
as zero (if PPPoE is operating, you also cannot modify IP/Subnet mask /Gateway). To
view the current IP information, you first need to disable the DHCP function.
IP address: Enter here your IP address. (For the IPv6 version, default gateway, preferred
DNS and alternate DNS, the default value shall be 64-digit.
Subnet mask (only for IPv4 option): Enter here your subnet mask address
Default gateway: Enter here the default gateway address.
TCP port: Default is 37777.
UDP port: Default is 37778.
HTTP port: Default is 80.
RTSP port: Default is 554.
MTU: Maximum transmission unit to be used with above ports. Default is 1500
Max connection: System supports maximal 128 users (default). 0 means there is no