Motorola DCP501 Installation Manual page 176

Home theater system
Hide thumbs Also See for DCP501:
Table of Contents

Advertisement

D 10: Application Code Modules
This diagnostic displays the currently downloaded code modules. This can be a multi-page
display. Press
SELECT
to display additional pages. The LEDs show the downloaded status.
The LED diagnostic indicates the current download status. The data received indicator lights
when downloaded data is received. The download packet counter counts down toward zero,
indicating the remaining packets of the current module to be received. This counter will initially
be blank, and after segment zero is received it shows the remaining packets. The data received
indicator can be lit even if no additional packets are stored.
Figure D-22 and Figure D-23 illustrate the application code module for LEDs and OSDs:
Figure D-22
Application code module LEDs
Table D-28 lists the mode for the first LED that indicates the current status of the download:
Table D-28
First LED indicating current status of download
First LED
Mode
Idle − no download in progress
I
C
Connected to download PID − awaiting data
Download in progress
D
Figure D-23
APP (application) CODE MODULES OSD
10
APP. CODE MODULES
MODULE
DCT_ROM
dct_plat
Appl_____
Receiving status
MUTE
Carrier
lock
Channel frequency
VER
07.40
07.44
2.00
P
MUTE
Forward
(MHz)
STATUS
DISABLD
ENABLED
DOWNLD
Diagnostics
D-31
ID
0000
0001
07DA
DCP501 Installation Manual