6.3 Bosch Gas Tankless Water Heater Specifi cations
Technical Specifi cations
Model
260 PN
Gas input
Min: 30,735
(BTU/hr)
Max: 74,900
Minimum fl ow to
0.6
activate (GPM)
Maximum fl ow rate
2.6
at 45° rise (GPM)
Maximum fl ow rate
1.3
at 90° rise (GPM)
Thermal Effi ciency
NG: 78%
LP: 78%
Dimensions
H: 28¾
(inches)
W: 12¼
D: 8½
Weight (lbs.)
25
Modulating gas valve
yes
Ignition
Standing
pilot
Gas connection
½" Male NPT
Water connections
½" Male NPT
NG gas pressure
Min: 7
(inches of W.C.)
Max: 14
LP gas pressure
Min: 11
(inches of W.C.)
Max: 14
Water pressure
Min: 30
Static - (PSI)
Min (well): 40
Max: 150
Electrical supply
N/A
Venting options
Vertical
natural draft
* horizontal
termination
not allowed
Venting diameter
4
(inches)
Vent material
Type B-vent
recommended
Note:
C 920 ES (residential model) has a maximum setpoint temperature
of 140°F.
C 920 ESC (commercial model) has a maximum setpoint
temperature of 180°F.
Note:
For specifi cations and details on the Bosch GWH 345 ESR and
GWH 450 ESR models, see the GWH 345 ESR and GWH 450 ESR
applications manual.
BOSCH THERMOTECHNOLOGY CORPORATION
425 PN
425 HN
Min: 31,000
Min: 30,735
Max: 117,000
Max: 117,000
0.6
0.6
4.2
4.2
2.1
2.1
NG: 78%
NG: 80%
LP: 78%
LP: 80%
H: 25¾
H: 25¾
W: 16¾
W: 16¾
D: 8½
D: 8½
33
33
yes
yes
Standing
Hydro-
pilot
generated
¾" Male NPT
¾" Male NPT
¾" Male NPT
¾" Male NPT
Min: 7
Min: 7
Max: 14
Max: 14
Min: 11
Min: 11
Max: 14
Max: 14
Min: 30
Min: 30
Min (well): 40
Min (well): 40
Max: 150
Max: 150
N/A
N/A
Vertical
Vertical
natural draft
natural draft
* horizontal
* horizontal
termination
termination
only with AQ4
only with AQ4
vent kit
vent kit
5
5
Type B-vent
Type B-vent
recommended
recommended
715 ES
C 800 ES
Min: 19,900
Min: 19,900
Max: 199,000
Max: 199,000
0.65
0.65
7.2
8.0
3.6
3.9
NG: 82%
NG: 92%
LP: 82%
LP: 92%
H: 30½
H: 30½
W: 17⅞
W: 17⅞
D: 11¼
D: 11¼
67
74
yes
yes
Electronic
Electronic
¾" Male NPT
¾" Male NPT
¾" Male NPT
¾" Male NPT
Min: 3.5
Min: 3.5
Max: 10.5
Max: 10.5
Min: 8
Min: 8
Max: 13
Max: 13
Min: 30
Min: 30
Min (well): 40
Min (well): 40
Max: 150
Max: 150
120VAC
120VAC
direct vent
direct vent
room-sealed
room-sealed
combustion
combustion
3 or 4
3 or 4
Stainless steel
PVC, CPVC,
(AL29-4C)
or ABS
(Schedule 40)
Bosch applications manual | 06.2009
| 11
C 920 ES/ESC
Min: 25,000
Max: 225,000
0.65
9.2
4.6
NG: 94%
LP: 94%
H: 30½
W: 17⅞
D: 11¼
88
yes
Electronic
¾" Male NPT
¾" Male NPT
Min: 3.5
Max: 10.5
Min: 8
Max: 13
Min: 30
Min (well): 40
Max: 150
120VAC
direct vent
room-sealed
combustion
3 or 4
PVC, CPVC,
or ABS
(Schedule 40)