AMS 500
ABSOLUTE MARKING SYSTEM
Manual Calibration
If the marking is off, note the difference on the "X" and "Y" axis. Ensure that the writing
arm can move freely, and that there are no obstructions (for example, a pen) on the plotting
surface.
Then select on the menu "Output Devices" and in the sub menu "Manual Calibration".
The writing arm will move to its default position and four cursor keys will appear in the
dialog box. These are used to move the plotter's carriage. The step size can be adjusted in the
range 0.025 mm to 10 mm. The default setting is 1/10 mm.
Move the writing arm to the proper position by use of the cursor keys. When the pen is
positioned precisely, click "Calibrate" on the screen. This completes the calibration process.
Close the window, now you can start using the program.