Initial Test Equipment Control Settings; Transmitter Alignment Options; Table 5-1. Initial Equipment Control Settings; Table 5-2. Transmit High/Low Power Level - Motorola CP185 Basic Service Manual

Hide thumbs Also See for CP185:
Table of Contents

Advertisement

Radio Programming and Tuning: Transmitter Alignment Options
5.4.1

Initial Test Equipment Control Settings

The initial test equipment control settings are listed in Table 5-1.
Monitor Mode: Power Monitor
RF Attenuation:
AM, CW, FM: FM
Oscilloscope Source: Mod
Oscilloscope Horizontal: 10 mSec/Div
Oscilloscope Vertical: 2.5 kHz/Div
Oscilloscope Trigger: Auto
Monitor Image: Hi
Monitor BW: Nar
Monitor Squelch: mid CW
Monitor Volume: 1/4 CW
5.5

Transmitter Alignment Options

Note: The maximum available power level given in the table below must NOT be exceeded.
There are separate alignment procedures for High and Low power.
Note: When checking the RF power output of the radio with a test set, always use a pad of
at least 30 dB attached to the radio end of the RF cable. This will avoid an RF
mismatch and ensure a stable RF reading that will not change with varying lengths of
connecting cable.
RF Band (MHz)
435
480M 4W 12.5/25K16C UHF 2
136
174M 5W 12.5/25K 16CH

Table 5-1. Initial Equipment Control Settings

Service Monitor
-
70

Table 5-2. Transmit High/Low Power Level

Test Set
Impedance: 24
Voltage: 7.5 Vdc
Ohm
Speaker/load:
DC on/standby: Standby
Load
PTT: OFF
Volt Range: 0 – 10 V
Current: 3.0 A
High Power
Model Number
AAH03RDF8AA7_N
4.2
AAH03KEF8AA7_N
5.0
Power Supply
Low Power
(W)
(W)
4.6
2.2
2.6
5.3
2.0
2.3
5-3

Hide quick links:

Advertisement

Table of Contents
loading