Appliance details
The maximum flue gas exhaust temperature on the 250 SX is 437°F (225°C)
Venting
Exhaust
Options
vent
diameter
and
material
Room
3 inch
sealed
stainless
(twin pipe)
steel
(AL29-4C)
sealed vent
pipe
Open
3 inch
combustion
stainless
(single
steel
pipe)
(AL29-4C)
sealed vent
pipe
Exhaust vent is always fan assisted. Installation of exhaust vent and combustion air piping may be run vertically or horizontally
and in separate directions if required.
* A maximum of three 90 degree elbows are permitted in the total vent length. The total vent length must be reduced by 1 ¼
feet for every 45° elbow used in the vent system.
** Stainless steel (AL29-4C) vent pipe is manufacturerd by Z-Flex, Protech and Heat Fab. NOTE: clearance distances are
variable depending if the vent pipe is installed in an enclosed or unenclosed space, the exhaust flue gas temperature and the
orientation of the vent pipe.
Table 2
10
* Exhaust
* Exhaust
vent
vent
maximum
minimum
length
length
26 feet (8
3 feet
m) with one
elbow. Less
2½ feet for
each
additional
90° elbow
26 feet (8
3 feet
m) with one
elbow. Less
2½ feet for
each
additional
90° elbow
Combustion
Combustion
air pipe
air pipe
diameter
maximum
and material
length
3 inch PVC,
26 feet (8
aluminum or
m) with one
galvanized
elbow. Less
pipe
2½ feet for
each
additional
90° elbow
See
See
chapter 2.8
chapter 2.8
Vent pipe
Vent pipe
clearances
clearances
within an
within an
unenclosed
enclosed
space
space
** See vent
** See vent
manufacturer's
manufacturer's
specifications
specifications
** See vent
** See vent
manufacturer's
manufacturer's
specifications
specifications
6 720 607 057