REFRIGERANT CHARGE (R-22 (oz)) ADJUSTMENT
7
FOR OPTIMUM PERFORMANCE
1) Copeland Scroll "KC" Compressors
ARI
rating pt.
Model
25 ft
PUG/H18
101
PUG/H24
98
PUG/H30
100
PUG/H36
105
PUG/H42
100
2) Copeland Scroll "K4/K3" Compressors
ARI
rating pt.
Model
25 ft
PUG/H18
80
PUG/H24
88
PUG/H30
96
PUG/H36
90
PUG/H42
102
Note: See Performance Data for Pressure/Temperature Charging.
Note: It is not necessary to remove refrigerant for linesets less than 100 feet; however, doing so will provide
some improvement of system efficiency.
Factory
Subtract Charge
Charge
25 ft
50 ft
75 ft
100 ft
-10
-7
-4
111
-10
-7
-4
108
-25
-17
-9
125
-25
-17
-9
130
-25
-17
-9
125
Factory
Subtract Charge
Charge
25 ft
50 ft
75 ft
100 ft
-10
-7
-4
90
-10
-7
-4
98
-25
-17
-9
121
-25
-17
-9
115
-25
-17
-9
127
Add Charge
125 ft
150 ft
3
7
3
7
8
8
8
8
8
8
Add Charge
125 ft
150 ft
3
7
3
7
8
8
8
8
8
8