Sanyo VPC-CG20 Service Manual page 19

Dual camera
Hide thumbs Also See for VPC-CG20:
Table of Contents

Advertisement

Adjustment value determination
AF_TEMP_AD: ATAD
ATAD: adjustment value of focus temperature A/D
(250<=ATAD<=893)
AF_WIDE: ZW
ZW: adjustment value of focus at zoom position wide
(–60<=ZW<=35)
AF_MID1: ZM1
ZM1: adjustment value of focus at zoom position middle1
(–90<=ZM1<=20)
AF_MID2: ZM2
ZM2: adjustment value of focus at zoom position middle2
(-78<=ZM2<=32)
AF_TELE: ZT
ZT: adjustment value of focus at zoom position tele
(–51<=ZT<=59)
3. AWB Adjustment
Camera
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Adjusting method:
1. Set a distance of 0.5-1.0 cm between the pattern box and
the camera. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Pattern box
(color viewer)
2
)
Dsc Calibration
AWB Results:
1:
WB=243,497,413
CHECK=128,128,122
MS=3848,4198
Fno_FOR_ISO=-1
SS_FOR_ISO=-1
YLEVEL_FOR_ISO=-1
Adjustment value determination is effectuated using the
"CHECK", "MS" values. If
CHECK = wc0, wc1, wc2
MS = ms1, ms2
the adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
wc0=128 ± 2, wc1=128 ± 2, wc2=150 ± 50
2000<=ms1<=4000, 2500<=ms2<=4500
Adjustment values other than the above are irrelevant.
4. CMOS White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select "CCD Defect" on the LCD "Test", and click the "Yes".
3. After the adjustment is completed, OK will display.
4. Click the OK.
– 19 –