Kenwood NXR-700 Service Manual page 51

Vhf digital base-repeater
Hide thumbs Also See for NXR-700:
Table of Contents

Advertisement

Adjustment Points
CN19
RX ANT
TC1
TC2
TC3
CN5
RX ANT
CN6
1
2
L28,30: Receive VCO Lock Voltage (Adjustment)
TC1~8: BPF
CN403
OUT
VR402
VR401
CN407
OCXO
CN402
REF_LV
CN408
IN
1
2
CN807
L108,128: Transmit VCO Lock Voltage (Adjustment)
VR401,402: Reference Signal
ADJUSTMENT
1
2
CN8
CN2
PA CURR
ANT SW
REF
FINAL UNIT (X45-3810-XX)
Component side
CN40
VE
TC4
TC5
TC6
CN36
1
2
L28
L30
TX UNIT (X56-3110-XX)
Component side
CN809
CN401
REF_LDT
REF_CV
OCXO UNIT
CN405
REF2
CN808
REF_IN
FC1 FC2
PWR CONT
PRT
VR2
PWR PRT
FWD
VR1
VR1: Coupler ADJ
VR2: High Transmit Power (Pre ADJ)
CN46
1 2
CN41
TC7
TC8
L46
RX UNIT (X55-3090-XX)
Component side
L128
CN66
RXA
CN65
ASQ
CN64
CV2
CN63
CV1
CN45
REF1
L46,52,74,90: MCF WIDE
L47,53,75,91: MCF NARROW
L128: Discriminator
CN302
CN301
MB
MOD
CN406
REF1
CN303
MB_CV1
NXR-700
CN1
TX IN
L91
L53
L75
L47
L52
L90
L74
CN47
CN43
CN203
CN802
VS1
TX OUT
CN201
CN811
VS2
CN202
TRG
D_PC
CN810
CN701
LDT
MO
L108
L128
CN101
CV
1
2
51