Fault Recovery/Diagnostics; Ups (Uninterruptible Power Supply) Integration - Panasonic KX-NS1000 Manual

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

5.6.1 UPS (Uninterruptible Power Supply) Integration

5.6 Fault Recovery/Diagnostics

5.6.1 UPS (Uninterruptible Power Supply) Integration
Description
An uninterruptible power supply unit (UPS) is a device that supplies power for several minutes to a connected
device when a power failure occurs.
If the PBX is connected to a compatible UPS via USB when a power failure occurs, the PBX can determine
how much power remains in the UPS and shut down when the remaining power drops below a specified amount
to prevent data loss or corruption.
Conditions
For details about UPS units that are compatible with the automatic shutdown feature of this PBX, consult
your dealer. If an incompatible UPS is connected and the UPS runs out of power, the PBX will turn off
without shutting down.
The power cord and USB cable must be connected to the same UPS. Connecting them to different UPSs
can result in incorrect operation.
When power is restored after a power outage, the PBX operates in the following manner:
If the PBX did not shut down, normal operation continues uninterrupted.
If the PBX shut down and power remains in the UPS, the PBX must be started again manually. (The
power switch must be turned off and then on again.)
If the PBX shut down and no power remains in the UPS, the PBX starts automatically. (This is because
the PBX's power switch is on.)
Installation Manual References
4.10 Connection of Peripherals
PC Programming Manual References
4.1.1 Status—Equipment Status—UPS
512