3-2. Resetting the computer
If an rewriting error occurs, close the Hyper Terminal, and then
repeat the procedure in 3-1. Setting up the computer from step
2.
3-3. Rewriting data
1. Follow the procedure in 3-1. Setting up the computer.
2. Turn on the power or the system controller, and check that
the initial display appears in the LCD. Then press the MENU
button to set to clock setting mode.
3. Press the 0 button and FUNCTION button simultaneously
to set to software rewriting mode.
The current version number appears in the system control-
ler LCD.
Press the CLEAR button if you want to cancel the opera-
tion.
4. Press the ENTER button to set to baud rate setting mode.
The baud rate setting display appears in the system con-
troller LCD.
Press the CLEAR button if you want to cancel the opera-
tion.
5. Press the [+] and [-] buttons to select the baud rate setting.
6. Press the ENTER button to set to software rewrite standby
mode.
The rewrite standby display appears in the system control-
ler LCD.
Initial display mode
S A N Y O
Clock setting mode
C L O C K
Software rewriting mode
[ V
O K : E N T E R N O : C L R
Baud rate setting mode
→ 3 8 4 0 0 ↔ 1 9 2 0 0 ↔ 9 6 0 0 ↔ 4 8 0 0←
Software rewrite standby mode
RS-232C
CONNECTOR
RS-232C
CONNECTOR
Fig. 10
- 8 -
C o n t r o l l e r
- - : - - : - -
S E T
2 . 0 0 ] R E W R I T E ?
R E W R I T E P R O G R A M
3 8 4 0 0 8 N 2 H A R D
Speed: 4800, 9600, 19200 or 38400
Data bits: 8
Parity: None
Stop bits: 2
Flow control: Hardware
← (+)BUTTON
R E W R I T E P R O G R A M
RESET
BUTTON
JK-405
(–)BUTTON →