Natural Gas Conversion - KitchenAid 30" (76.2 CM) FREESTANDING AND SLIDE-IN DUAL FUEL RANGES Installation Instructions Manual

Hide thumbs Also See for 30" (76.2 CM) FREESTANDING AND SLIDE-IN DUAL FUEL RANGES:
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT: The TripleTier
spuds. Be sure to change the external gas orifice spud
located under the plate.
B
C
A. Plate
B. External gas orifice spud
C. Internal gas orifice spud
4. Apply masking tape to the end of a 7 mm nut driver to help
hold the internal gas orifice spud in the nut driver while
changing it. Press nut driver down onto the internal gas
orifice spud and remove by turning it counterclockwise and
lifting out. Set internal gas orifice spud aside.
5. Use a 7 mm combination wrench to remove the external gas
orifice spud. Turn counterclockwise to remove. Set external
gas orifice spud aside.
6. Replace the Natural gas orifice spud with the correct LP gas
orifice spud. Refer to the following chart for correct LP gas
orifice spud placement.
LP Gas Orifice Spud Chart for TripleTier
Burner Location
Burner Rating
Left front (external
11,800 Btu/h
TripleTier
®
burner)
Left front (internal
2,200 Btu/h
TripleTier
®
burner)
7. Replace burner plate, head and cap.
8. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with the package containing literature.
9. Reinstall the warming drawer. See the "Replace Oven Racks
and Warming Drawer" section for instructions.
10. Complete installation. See "Make Gas Connection" and
"Electronic Ignition System" sections.
Checking for proper cooktop burner flames is very important.
The small inner cone should have a very distinct blue flame
¼" to ½" long. The outer cone is not as distinct as the inner
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
®
Flame burner has 2 gas orifice
A
®
Flame Burners
Color
Size
Brown
1.00 mm
Orange
0.42 mm

Natural Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the "closed" position.
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
2. Unplug range or disconnect power.
3. Remove warming drawer. See the "Remove Warming
Drawer" section for instructions. Locate gas pressure
regulator at rear of warming drawer compartment.
4. Remove access cover from the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
5. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
6. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "LP" or "NAT" position.
7. Turn over the spring retainer so the "NAT" is showing on the
bottom.
8. Snap the spring retainer back into the cap.
B
C
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

30" (76.2 cm) gas built-in cooktop

Table of Contents