TO THE OWNER Before operating this Plasma Monitor, read this manual thoroughly and operate the Plasma Monitor properly. This Plasma Monitor provides many convenient features and functions. Operating the Plasma Monitor properly enables you to manage those features and maintains it in better condition for a considerable time. Improper operation may result in not only shortening the product-life, but also malfunctions, fire hazard, or other accidents.
Mount Unit . Use with other stands or mount units is capable of has been damaged. resulting in instability causing possible injury. f. When the Plasma Monitor exhibits a distinct change in SANYO Table top stand KA-TD-H10S performance-this indicates a need for service. SANYO Tilt mount unit KA-TI-H10 SANYO Wall mount unit...
Model Number : PDP-42H1EN/PDP-42H1ENV/PDP-42H1AN Trade Name : Sanyo Responsible party : SANYO FISHER COMPANY Address : 21605 Plummer Street, Chatsworth, California 91311 Telephone No. : (818)998-7322 G This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
TABLE OF CONTENTS FEATURES AND DESIGN COMPUTER MODE SELECTING INPUT SOURCE SELECTING COMPUTER SYSTEM PC ADJUSTMENT PREPARATION NAME OF EACH PART OF PLASMA MONITOR 7 SETTING-UP PLASMA MONITOR VIDEO MODE SELECTING INPUT SOURCE SELECTING VIDEO SYSTEM CONNECTING PLASMA MONITOR TERMINALS OF PLASMA MONITOR CONNECTING TO VIDEO EQUIPMENT SETTING CONNECTING TO COMPONENT VIDEO EQUIPMENT...
G There may be some tiny black points and/or blight points on the Plasma Display Panel. These points are normal. ✽ NOTES ON OWNER'S MANUAL This owner's manual described with the models PDP-42H1ENV and PDP-42H1AN. Some of terminals are not provided on model PDP-42H1EN. (Refer to the terminal figure on page 12. )
PREPARATION NAME OF EACH PART OF PLASMA MONITOR FRONT PLASMA DISPLAY PANEL FRONT CONTROLS AND INDICATORS MENU BUTTON CURSOR BUTTON FRONT CONTROLS Used to set and adjust the Used to select MENU menu data on On-Screen operation. (P18) Menu. (P18) OK BUTTON Used execute...
Page 8
PREPARATION NAME OF EACH PART OF PLASMA MONITOR BACK This Plasma Monitor detects COOLING FANS internal temperature and automatically controls operating power of Cooling Fans. TERMINALS AND CONNECTORS (SIDE) SPEAKER OUTPUT (Refer to page 11) TERMINALS (RIGHT) SPEAKER OUTPUT TERMINALS POWER CORD (LEFT) CONNECTOR...
PREPARATION SETTING-UP PLASMA MONITOR CONNECTING AC POWER CORD This Plasma Monitor uses nominal input voltages of 100- 120 V or 200-240 V AC. The Plasma Monitor automatically selects the correct input voltage. It is designed to work with single-phase power systems having a grounded neutral conductor.
Page 10
PREPARATION INSTALLATION OF OPTIONAL SPEAKERS AND STAND Please read the each option's instruction manual (or installation manual) for the installation. CAUTION IN INSTALLATION G Through installation work, handling with more than two people is recommended. G When holding (moving or lifting) the Plasma Monitor, hold the Monitor's body. Do not handle it by holding the attached accessory parts (the Speakers), otherwise damage could be result.
CONNECTING PLASMA MONITOR TERMINALS OF PLASMA MONITOR This Plasma Monitor has INPUT TERMINALS and OUTPUT TERMINALS on its side and back, for connecting computers and video equipment. Refer to the figure on pages 13 to 15 and connect properly. SIDE BACK (Left) VIDEO3 INPUT JACKS...
Page 12
CONNECTING PLASMA MONITOR ✽ The connection jacks on this page are not provided on the model PDP-42H1EN. BACK NOTE: Video input jacks have following priority. When you connect 2 or 3 cables on (Center) the same input and other inputs are disconnected, S-VIDEO jack has (Right) priority over BNC jack, and BNC...
CONNECTING PLASMA MONITOR CONNECTING TO VIDEO EQUIPMENT NOTE : These connections are for models PDP-42H1ENV and PDP-42H1AN only. Cables used for connection ( Cables are not supplied with this Plasma Monitor.) • 21 PIN Video Cable (RCA x 6) • Video Cable (BNC x 1) NOTE : •...
CONNECTING PLASMA MONITOR CONNECTING TO COMPONENT VIDEO EQUIPMENT NOTE : These connections are for models PDP-42H1ENV and PDP-42H1AN only. Cables used for connection (Cables are not supplied with this Plasma Monitor • Video Cable (RCA x 3) or (BNC x 3) NOTE : •...
43. Core Use either "PC IN" Terminal or "COMPONENT/RGB"(VD, HD, R, B and G) jacks. REAR TERMINALS NOTE : These connections are for models PDP-42H1ENV and PDP-42H1AN only. VIDEO VIDEO AUDIO Pr/Cr Pb/Cb AUDIO...
BEFORE OPERATION OPERATION OF REMOTE CONTROL Remote Control Unit can be used as either Wired or Wireless. WIRED REMOTE JACK COMPONENT BUTTON When using as Wired Remote Used to select COMPONENT Control, connect Remote Control VIDEO input. (P22) Cable to this jack. (P17) POWER ON-OFF BUTTON VIDEO BUTTON Used to turn Plasma Monitor on...
BEFORE OPERATION WIRED REMOTE CONTROL OPERATION NOTE: Wireless Remote Control does not work When using this Remote Control Unit as Wired Remote when Remote Control Cable Control, Connect Remote Control Unit to R/C JACK with connected on Plasma Monitor. Remote Control Cable (supplied). Batteries installation is required when using as Wired Remote Control Unit.
BEFORE OPERATION OPERATING ON-SCREEN MENU You can control and adjust this Plasma Monitor through ON-SCREEN MENU. Refer to the following pages to operate each adjustment on ON-SCREEN MENU. BUTTONS OF ON-SCREEN MENU OPERATION OFF TIMER REMOTE CONTROL UNIT CURSOR Used to execute Used to select PICTURE MOVE UP...
BEFORE OPERATION MENU LIST Contrast Contrast : Select : Adjust (P24) MENU : Return STATUS : Exit Contrast Brightness Brightness Brightness : Select : Adjust (P24) Color MENU : Return STATUS : Exit Tint Sharpness Color Color Sound : Select : Adjust Screen adjust (P24)
BASIC OPERATION TURNING ON / OFF PLASMA MONITOR Complete the peripheral connections (with Computer, VCR, etc.) before turning on Plasma Monitor. (Refer to "CONNECTING PLASMA MONITOR" on Pages 13~15 for connecting that equipment.) Connect the Plasma Monitor's AC Power Cord into an AC outlet . VOLUME Press MAIN ON/OFF switch on Front Control of Plasma Monitor to turn ON.
BASIC OPERATION WHEN USE MULTIPLE MONITORS When you use multiple Plasma Monitors, you can use POWER ON button and POWER OFF button on Remote Control Unit instead of the STATUS MENU POWER ON-OFF button. POWER POWER Press POWER ON button to turn Plasma Monitor ON so as not to affect another Plasma Monitor which may be already turned ON.
BASIC OPERATION SELECTING INPUT SOURCE VIDEO INPUT Select “AV1 (VIDEO1),” “AV2 (VIDEO2),” or “AV3 (VIDEO3)” by pressing VIDEO button on Remote Control Unit. (Refer to “CONNECTING TO VIDEO EQUIPMENT” on Page 13.) COMPONENT INPUT Select “Component” by pressing COMPONENT button on Remote Component Control Unit.
BASIC OPERATION PICTURE IMAGE LEVEL SELECT IN VIDEO/COMPONENT MODE Select image level among Dynamic, Natural, Cinema and Memory by pressing PICTURE button on the Remote Control Unit. Dynamic Dynamic High contrast picture level preset on this Plasma Monitor. Natural Natural Normal picture level preset on this Plasma Monitor.
BASIC OPERATION IMAGE LEVEL ADJUSTMENT MENU Press MENU button and ON-SCREEN MENU will appear. Contrast Brightness Press buttons to select the item that you want to adjust, Color and then press OK button. The level of selected item is Tint displayed.
BASIC OPERATION WIDE SCREEN OPERATIONS With this function, you can select screen size. WIDE button SELECTING WIDE MODE Natural wide Select screen size among "Natural wide", "Zoom", "Zoom(Caption- Zoom IN)", "Full" and "Normal" by pressing WIDE button on the Remote Control Unit.
BASIC OPERATION UP/DOWN PICTURE To move up/down the image vertically, press the MOVE UP / MOVE OFF TIMER DOWN buttons. PICTURE MOVE UP MUTE NOTE : MOVE UP Up/down picture function can work only when the input signal mode button is "AV1 (VIDEO1)", "AV2 (VIDEO2)", "AV3 (VIDEO3)"...
BASIC OPERATION SOUND ADJUSTMENT VOLUME Indicates the roughly level (yellow) of volume. Press VOLUME (+/–) button(s) on Remote Control Unit or Front Control to adjust volume. Volume dialog box appears on the screen Volume for a few seconds. (+) button to increase volume, and (–) button decreasing. MUTE (red) Press MUTE button on Remote Control Unit to cut off sound.
COMPUTER MODE SELECTING INPUT SOURCE REMOTE CONTROL OPERATION Select "PC" or "RGB1" by pressing PC/RGB button on Remote Control Unit. RGB1 RGB2 FRONT CONTROL OPERATION Select "PC" or "RGB1" by pressing INPUT button on Front Control. NOTE : "RGB2" is used for RGB Video signals from 21-PIN connector. (Refer to "CONNECTING TO VIDEO EQUIPMENT"...
COMPUTER MODE PC ADJUSTMENT PC MODE ADJUSTMENT "PC mode adjustment" menu is provided to adjust "Auto setup", "Clock", "Phase", "Position", "Power save" and "Information" to conform to your computer. These function can be operated as follows. Press MENU button and ON-SCREEN MENU will appear. "PC mode adjustment"...
Page 30
COMPUTER MODE Power save PC mode adjustment Enable or disable Power save function. Power save Enable Power save by choosing "Yes" with buttons. : Adjust NOTE : MENU : Return STATUS : Exit The Power save function automatically reduces the Plasma Monitor's power consumption if the computer is not operated for a certain period of time.
Page 31
COMPUTER MODE COMPATIBLE COMPUTER SPECIFICATIONS Basically this Plasma Monitor can accept the signal from all computers with the V, H-Frequency mentioned below and less than 100 MHz of Dot Clock. SYSTEM H-Freq. V-Freq. RESOLUTION MODE (kHz) (Hz) 640 x 480 31.47 59.88 640 x 400...
VIDEO MODE SELECTING INPUT SOURCE VIDEO INPUT Select either "AV1 (VIDEO1)" or "AV2 (VIDEO2)" or "AV3 (VIDEO3)" by pressing VIDEO button on Remote Control Unit. When the connection of 21-PIN video signals is on, "RGB2" should be selected by pressing PC/RGB button on Remote Control Unit. RGB2 COMPONENT INPUT Component...
VIDEO MODE SELECTING VIDEO SYSTEM VIDEO JACK OR S-VIDEO JACK "Setup menu" Press MENU button and ON-SCREEN MENU will appear. Language English Color system Auto Screen saver Press buttons to select "Setup menu" and then press OK Dynamic AI button. "Setup menu" will appear. Child lock ECO mode Start mode...
SETTING SCREEN SAVER FUNCTION Displaying a still picture (non-movement) on the screen for a long time cause afterimage (ghost) on the screen. To neutralized the remaining image, Screen Saver function (3 modes) is provided in the Monitor. Use the function conveniently. SELECTING SCREEN SAVER "Screen saver"...
SETTING SETTING MENU Press MENU button and ON-SCREEN MENU will appear. "Setup menu" Language English Color system Auto Screen saver Press buttons to select "Setup menu" and then press OK Dynamic AI button. "Setup menu" will appear. Child lock ECO mode Start mode Press buttons to select the item that you want to setup,...
SETTING Color temperature This function is used for selecting color temperature. Select "Normal", "Cool" or "Warm" with buttons which you wish to select. No operation shut off timer This function turns off Plasma Monitor's power automatically, when there is no operation of Remote Control or Front Control for 3 hours. When "On"...
APPENDIX TROUBLESHOOTING Before calling your dealer or service center for assistance, check the matters below once again. 1. Make sure you have connected Plasma Monitor to your equipment as described in the section "CONNECTING PLASMA MONITOR" on pages 13 ~ 15. 2.
APPENDIX Problem: Try these Solutions G There may be some tiny black points and/or bright points on PDP (Plasma Display There are tiny black Panel). These points are normal. points and/or bright points on the PDP. G The Plasma Monitor has trouble, and Self Diagnose function activates. The POWER (Refer to P39) indicator is flashing.
APPENDIX INTERNAL TEMPERATURE MONITOR This function activates due to the temperature inside Plasma Monitor. When the temperature inside Plasma Monitor exceeds the normal, after displaying a message, Plasma Monitor will be turned off automatically. When the message "Warning! Internal temperature is too high." is displayed. When this message is displayed, the internal temperature of Plasma monitor exceeds normal.
WOOFER OUT ✽ RCA type POWER SUPPLY AC 200 - 240V 50/60 Hz (PDP-42H1ENV, PDP-42H1EN) AC 100 - 120V 50/60 Hz, AC 200 - 240V 50/60 Hz (PDP-42H1AN) DIMENSION (W x H x D) 41.4" x 25.2" x 4" ) (Plasma Monitor only)
APPENDIX MEASUREMENT 1036 (41.4) (4.0) 1036 (41.1) (25.2) Size in mm (inch) OPTIONS The products listed below are optionally supplied. When ordering these products, give name and Type No. to sales dealer. Speaker unit KA-SX-42H (R and L) Table top stand KA-TD-H10S Side rack KA-TD-R100...
Page 42
APPENDIX CONFIGURATIONS OF RS232C TERMINALS RS232C TERMINAL Terminal : HDB9-PIN Connect the serial port of computer to this terminal with Serial Cross Cable (not supplied). Pin Configuration INTERFACE No Connect Protocol RS-232C R x D No Connect Baud rate 9600 bps T x D No Connect Data length...
Page 43
APPENDIX CONFIGURATIONS OF PC TERMINALS PC IN (D-SUB) TERMINAL Terminal : HDB15-PIN Connect the display output terminal of computer to this terminal with VGA Cable (not supplied). When connecting the Macintosh computer, the MAC Adapter (not supplied) is required. Pin Configuration Red Input No Connect Green Input...
Page 44
Printed in Japan Part No. 610 305 6777 (1AA6P1P3518A- J3RGB) SANYO Electric Co., Ltd...