Filter Cleaning - Kenmore ENVIROSENSE 85500 Operator's Manual

True hepa air cleaner
Table of Contents

Advertisement

Available languages

Available languages

For y our
convenience, all three filters (Pro-
Filter, Washable Nano-Silver/Carloon Filter,
and True HEPA Filter) come in one pre-
packaged replacement cassette.
For optimum unit efficiency, wash the Pre-
Filter and Washable Nano-Silver/Carbon
Filter as described below (Filter Cleaning)
every three months.
Do not wash and reuse the True HEPA
Fitter_tt will not work effectively.
replacing or cleaning t
WARNING:
Before
any filters, make sure to remove the
powerplug from the wa out et.
Replacement
Procedure
1,Remove the front panel by pullinggently
on the sliver tabs
located on each side
of the unit,
2. Pull out the filter cassette by grasp!rig tile
black tabs located
on each side.
3. Remove the plasticwrap from the new
filter cassette.
4. Place the new filter cassette
in the
main unit,
5, Replace the front
panel.
6. Plug in the power cord to a we1|outlet
and turn on the unit,
7. To turn off the CHANGE FILTER
INDICATOR, press the FUNCTION and
OFF ]IMER buttons at the same time for
five seconds; the CHANGE FILTER
INDICATOR will flash five times and turnoff.
Filter Cleaning
we recommend cleaning the Pro-Fitter (A)
and tile Nano_Silver/CarbonFilter (C) every
three monthswith normal use, The interval
between cleanings will vary based on room
conditions.
1.Remove the front panel and filter
cassette as described in Replacement
Procedure.
2, Remove the Pro-Filter by gentlypulling
one side of the cassette frame outward
while lifting the Pro-Filter tab at the same
time. When one edge is clear of the
frame, the Pro-Filter will slide out for
cleanii_
3. Lightty vacuum the Pra-Fitter andwash
with water and a mildhousehold deter-
gent. Rinse, end shake offexcess water.
4. To remove the Washable Nano-SIIverl
Carbon Fitter, turn the cassette over and
place facedown on an even surface.
Grasp the lall white tab nearest tothe
gray lab, Slightlyflex the cassette frame
outward while pullingup on the gray
lab. When the first corner is released,
pulloul on the olher tall frame tab while
continuingto pullup on the gray tab.
When one long edge of the filter is free,
slide out for cleaning,
5, Wash the filterin warm water with a mild
householddetergent, Rinse, and shake
off excess water,
6. Do not dry the two _ters--running
the
unit will be sufficient to drythem.
7. Replace each filter in the cassette frame
by insertingone tong edge first, then
snapping intoplace by pushing sideways
and down at the same time. Make sure
both fittersare completelyinside the
cassette frame and secured by the short
tabs. If a filter Is on top of one or more
tabs, pulloutward,slightly flexing the
cassette frame, while gently pushing
down on the edge of {he filter,
8, Replace the filter ¢_ssette and front
panel as described in Replacement
Procedure.
g Plug in the power card to a wall outtet
and turn on the unit.
Note: Neveratlem!_to removetheTrue HEPA1
Filterfrom _e cassette frame. Neverattemptto
cleanthe Tlue HEPA Filler.Replaoetheentire
casselteonlywhenCHANGE FILTERalert
t
activates.(Model85500mplacoment#85501; I
Model85501 replacement # 85511)
j
NANO-SILVER!CARBON FILTER
CASSETTE
SHORT TABS
GRAY TAB
! CASS ETT_
LONG TAB
FRONT SIDE
PlasrnaDoctor
TM
Display Panel
I)C Motor
Washable Nano-
SiivertCarbon F_tler
Filler Cassette with
1"rueHEPA Filter inside
- Front Panel
PowerP_g
Air Outlet
TOP SIDE
Remme
CanI_l
C_d_