Download Print this page

Kenmore LIQUID PROPANE GAS (LPG) GRILL 119.1623 Operator's Manual page 23

Liquid propane gas grill

Advertisement

Notes about LP Gas Tank Exchange
Programs
• Many retailers that sell grills offer you the option of
replacing your empty LP gas tank through an
exchange service. Use only those reputable
exchange companies that inspect, precision fill, test
and certify their tanks. Exchange your tank only for
an OPD safety
feature equipped tank as described
in the LP gas tank section of this manual.
• Always keep new and exchanged LP gas tanks inan
upright position during use, transit or storage.
• Leak test new and exchanged
LP gas tanks BEFORE
connecting one to your grill.
How
to Leak
Test
your
LP Gas Tank
For your safety:
All leak tests must be repeated each time your LP gas
tank is exchanged or refilled.
Do not smoke when checking for gas leaks.
Do not use an open flame to check for gas leaks.
Your grill must be leak tested outdoors in a
well-ventilated
area, away from ignition sources such
as gas fired or electrical appliances.
During the leak
test, keep your grill away from open flames or
sparks.
Do not use household cleaning agents as damage to
gas assembly components
can occur.
[]
Use a clean paintbrush
and a 50/50 mild soap and
water solution.
[]
Brush soapy solution onto the LP gas tank in the areas
indicated by the arrows. See diagram.
[]
If growing bubbles appear do not use or move the LP
gas tank. Call an LP gas supplier or your fire
department.
Regulator
and LP Cylinder
Connections
The gas pressure
regulator
provided
with this
outdoor
cooking
appliance
must
be used. This
regulator
is set for an outlet
pressure
of 11
inches
water
column.
Regulator:
Your regulator
is equipped
with
a q.c.c.
Type 1
quick connect
system.
It will not allow
gas to flow
until a positive
seal has been made.
It has a
thermal
element
that will shut off the gas flow if
the temperature
reaches
240 degrees
F (115
degrees
C). It also has a flow-limiting
device
that
will restrict
the flow of gas to 10 cubic feet per
hour (0.28
cubic meters
per hour).
TO CONNECT
THE CYLINDER
TO THE
REGULATOR
AND
HOSE
1. Be sure the LP cylinder
is "OFF" by turning
the
hand wheel clockwise
until it stops.
2. Place the cylinder
into the base cabinet
shelf of
the
grill
with
the
valve
facing
outward
and
secure with the cylinder
support
ring.
3. Be sure
all burner
controls
are turned
to the
"OFF" position.
4. Remove
the safety
cap from
the cylinder
valve.
5. Center
the nipple
of the regulator
into the
cylinder
valve.
6. Turn the black nut clockwise
until it stops.
Hand Tighten
Only,
Do Not Use A Wrench,
',,,%
Type
I
onsection
p_
..... "ANSI
Z21,58bo2002
If growing
bubbles
appear
do not use or move
the LP gas tank.
Contact
an LP gas supplier
or
your fire department!
CAUTION:
When the appliance
is not in use
the gas must
be turned
off at the tank.