NORMAL
INSTALLATION
STEPS
Provide Adequate
Gas Supply
The range
is designed
to operate
at a pressure
of 4
inches of water column
on natural
gas or, if designed
for LP gas (propane
or butane),
10 inches
of water
column.
Make sure the range is supplied
with the type
of gas for which
it is designed
If, at any time in the
future, the range is to be supplied
with a different
type
of gas, conversion
adjustments
must be made by a
qualified
service technician
before attempting
to oper-
ate the range on that gas.
For proper operation,
the pressure
of natural gas sup-
plied to the regulator
must be between
4 and 13 inch-
es of water column
For LP gas, the pressure
supplied
must be between
10 and 13 inches of water column
When
checking
for proper
operation
of the regulator,
the inlet pressure
must be at least t inch greater
than
the operating
(manifold)
pressure
as given above. The
pressure
regulator
located
at the inlet of the range
manifold
must remain in the supply fine regardless
of
whether
natural
or LP gas is being
used
A flexible
metal appliance
connector
used to connect
the range
to the gas supply line should
have an tDo of 1/2" and
be 5 feet in length
(shorter
and longer
lengths
are
acceptable)
for ease of installation
2
Connect the Range to Gas
Before disconnecting
the old range, shut off the main
gas supply
valve and leave
it off until new hook-up
has been completed
Because
hard piping restricts
movement
of the range,
the use of an AoG.A.-certified
flexible metal appliance
connector
is recommended
unless local codes require
a hard-piped
connection
Never use an old connector
when installing
a new range
To prevent
gas
leaks,
wrap
pipe thread
tape
with
Teflon*
around,
or put pipe joint
compound
on, a!l
male (external)
pipe threads
"Teflon: Registered trademark of DuPont
Gas Pipe and Electric
Outlet Locations:
for t20V outlet on
rear waif and area
ler thru the wall con-
nection of pipe stub
and shut-off valve
Recommc
_
for thru tile floor con-
nection of pipe stub
/
and shut-off valve
.
Flexible Connector
Hookup
Rigid Pipe Hookup
Pressure Regulator
"_ _L,
Adapter4-_
"_
Nipp,e
Adapter4J
'_
90"
.
Elbow
Gas F1ow
tale Range
_
-_lll
Manifold Pipe
Flex Connector
Adapter
Adapter _
Nipple
Gas sh°"°' va've-- 'kl
J
Installer: _nform the consumer
_
Ill
1/2" or 3_,,
_
lit
of the local!on of the gas
Gas
i e---._
shut-off valve
_
P p
"_
_
1. Install
a manual
gas line shut-off
valve
in the gas
line in an easily
accessed
location
outside
of the
range
Make
sure
everyone
operating
the
range
knows where and how to shut off the gas supply to the
range,
2. Install male 1/2" flare union adapter to the 1/2" NPT
internal thread
at inlet of pressure
regulator.
3. Install
male I/2"
or 3/4" flare union adapter
to the
NPT internal
thread of the manual
shut-off valve,
tak-
ing care to back up the shut-off
valve to keep it from
turning
4. Connect
flexible
metal appliance
connector
to the
adapter
on the range.
Position
range to permit
con-
nection at the shut-off valve