Installation
Instructions
(cont'd)
Installation
Checklist
BEFORE LIGHTING
THE PILOT:
• Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for gas leaks
using a match or open flame.
b. Brush the soapy water solution on all gaspipes, joints and
fittings.
c. Check for bubbling soap• This means you have a leak.
Turn OFF" gas and make the necessary repairs.
d. Recheck for leaks.
e. Rinse offsoapy solution and wipe dry.
• Is the new temperature-pressurereliefvalveproperly installed
and piped to art adequate d_in? See _Temperatttre-Pressure
ReliefValve"section•
• Are the cold and hot water lines connected
to the water
heater correctly?
See "Water Piping" instructions
in the
_lnstallation Instructions _ section.
• Is the water heater completdy filled with water? See "Filling"
instructions in the Installation Instructions
section.
• Will a water leak damage
anything?
See the "Facts to
Consider About the Location" section.
• Is there proper clearance between @e water heater and any-
thing that might catch fire? See the Facts to Consider About
the Location" section.
• Do you have adequate ventilation
so that the water heater
will operate propetly? See Combustion
Air and Ventilation
in the _Facts to Consider About the Location" section.
'"
ly
....
• Is the draft hood vent piping proper
secured. See Ventmg_
instructions
m
the Installation
Instructions
section.
• Is there proper dearance betw_n
the vent pipe and anything
that might catch on fire. See Venting
instructions
in the
"Installation Instructions" section.
HOT
GAS SUPPLY
TEE
(Sediment
trap)
PIPE CAP
DRAIN
VALVE '
VENT
PIPE TO
OUTDOORS
OR CHIMNEY
DRAFT
HOOD
SHUTOFF
VALVE
• Is the vent pipe properly sloped and does the vent terminate
outdoors? See "Venting" instructions
in the "Installation
Instruct ons
seCtiOn.
• Do you need to call your gascompany to check the gas pipe
and its hookup?
UNION
SHUTOFF VALVE
COLD
PRESSURE
REUEF
VALVE
(Do
not rap
or
plug)
i
6" AIR GAP