Troubleshooting
Guide
Start Up Conditions
THERMAL
EXPANSION
Water supply
systems may, because of such events as high line
pressure,
frequent
cut-off_, the effects of water hammer
among
others,
have installed
devices such as pressure
reducing
valves,
check valves, back flow preventers,
etc.-to
control these types of
_roblems.
When these devices are not equipped
with an internal
y-pass, and no other measures are taken, the devices cause the
water system to be dosed. As water is heated, it expands
(ther-
mal expansion)
and closed systems do not allow for the expan-
sion of heated water.
The water within the water heater tank expands as it is heated and
increases the pressure of the water system. If the relieving point of
the water heater's temperature-pressure
relief valve is reached, the
valve will relieve the excess pressure. The temperature-pressure
relief valve is not intended
for the constant
relief of thermal
expansion.
This is an unacceptable
condition
and must be cor-
rected.
It is recommended
that any devices installed which could create a
closed system have a by-pass and/or
the system have an expan-
sion tank to relieve the pressure
built by thermal
expansion.
Thermal
expansion
tanks are available
from Sears stores and
through
the Sears Service Centers.
Contact
the local plumbing
inspector,
water supplier
and/or
the Sears Service Center
for
assistance in controlling
these situations.
Thermal
Expansion
Tank
Specifications
Model
_lhnk Capacity
Dimensions in Inches
Pipe Fitting
Number
In Gallons
Diameter
Length
On "Ihnk
153.331020
2
8 inches
12_ inches
74"Male
153.331050
5
11 inches 14_ inches
74"Male
Expansion
Tank Sizing
Chart
Expansion
_nk
Capacity
Needed
Inlet*
Water
Pressure
40psi
50psi
60psi
70psi
80psi
Water Heater Capacity (Gallons)
30
40
50
66
80
2
2
2
5
5
2
2
2
5
5
2
2
5
5
5
2
2
5
5
5
2
5
5
5
5
*Highest
recorded
inlet water pressure in a 24 hour period
or
regulated water pressure.
NOTE:
Expansion
tanks
are pre-charged
with
a 40 psi air
charge.. If the inlet, . water pressure
is higJ.her than 40 psi, the
expansmn
tanks
a_r pressure
must be adjusted
to match
that
pressure, but must not he higher than 80 psi.
HOT
COU_
WATER
HEATER
(3)
- COLD WATER
PRESSURE
INLET FITTING
REDUCING
VALVE WITH
BY-PASS
(0
1
EXPANSION
TANK
(z)
PRESSURE G AUGE
WATER
SHUTOFF
RECOMMENDED INSTALLATION
(VERTICAL MOUNTING)
WATER HEATER
COLD WATER
INLET FITTING
FLOOR, CEILING
JOIST, ETC.
HOT
COLD
STRAPPING
O)
EXPANSION
TANK
(3)
PRESSURE
REDUCING INLETCOLD
VALVE WITH
WATER
BY-PASS
SHUTOFF
(z)_
PRESSURE G AUGE
ALTERNATE RECOMMENDED
INSTALLATION
(HORIZONTAL MOUNTING)
STRANGE
SOUNDS
Possible noises due to expansion and contraction of some metal
_arts during periods of heat-up and cool-down do not represent
armful or dangerous conditions.
21