MEA 1786FD2 CRT Monitor Service Guide
10. TILT CKT
We can rotate raster clockwise or counterclockwise by changing the direction of the current flow
through the tilt coil.
When the voltage of MP202(pin3) is larger than 6.5V, the current flows from Q205 to Tilt coil, other
wise , the current flows from tilt coil to Q206
Fig 10 TILT circuit