Alarm - Siemens CFMC1315-LP Configuration

1/3” 1.3 mp indoor ip dome colour camera
Hide thumbs Also See for CFMC1315-LP:
Table of Contents

Advertisement

9.4.1

Alarm

Building Technologies
Fire Safety & Security Products
For usage of external alarm inputs you need to define the following parameters:
1. Select Alarm > Alarm.
2. Configure the options as described in the tables below.
3. Click Save.
Alarm Input
ON: Detects an external alarm.
OFF: Does not perform alarm detection.
Digital Input
Alarm Input: Detects an external alarm.
Mode
OFF: Does not perform alarm detection.
Input Type
NO (Normally Opened): An alarm will be triggered when the external
contact closes.
NC (Normally Closed): An alarm will be triggered when the external
contact opens.
Text Enable
Define whether an alarm text will be overlaid on the video image.
Text
Define a text for the alarm message. Max. 24 characters can be
entered.
Audio Output
When set to ON, an audio alarm message can be sent to an external
speaker.
NOTE: A speaker with integrated amplifier must be connected to the
AUDIO out jack on the rear panel.
Event
Select the pre-recorded sound file (on the SD card) to be output as a
sound alarm. See page [
39] .
CFMC1315-LP Configuration Manual EN
Configuration
37
05/05/2009