Summary of Contents for Siemens HiPath optiPoint 100 advance

  • Page 1 HiPath optiPoint 100 advance Installation and Startup...
  • Page 2  Siemens AG 2001 Information and Communication Networks, Hofmannstraße 51, D-81359 München Reference No.: A31003-H4100-A102-1-74D1 Made in Germany. Subject to availability. Right of modification reserved. HiPath is a trademark of Siemens AG that is registered in Germany and other jurisdictions.
  • Page 3: Preparing The Telephone

    This guide for Installation and Startup describes how to connect the components of the optiPoint 100 advance telephone and how to integrate the telephone into a LAN environment. Administrators who wish to install and configure IP phone telepho- ny devices via a web interface will find detailed informations in the "Administrator Manual".
  • Page 4 Latch the four-pin (red) Western plug (RJ 11) of the power sup- ply unit cord in the receptacle (1) on the bottom of the tele- phone. Feed the power supply unit cord through the guide channel in the base unit. The Western plugs of all cable connections must audibly snap into place.
  • Page 5 Assign telephone number in a HiPath system with DHCP server After the automatic assignment of an IP address the following dis- play is shown: > 13:05PM bbbbbbbbbbb 07.02.01 Change to "Service" and Only IP-dialing possiblebb > call menu Service: Enter digit "6" 1=Status? >...
  • Page 6 Setting up the optiPoint 100 advance in a HiPath system without DHCP server If there is no DHCP server integrated into your HiPath environ- ment, you have to enter the IP address and the subnet mask ma- nually via your dialling keypad. First you have to switch off the DHCP function.
  • Page 7 Stay in the "network" menu and enter an IP address for the tele- phone and for the subnet mask: > Change to Network: 01=DHCP IP assign? > "Terminal IP-Adr." Network: d ddddddddd 0.0.0.0 Confirm 02=Terminal-IP-Adr? dddddd > Terminal-IP-Adr dddd 0.0.0.0 Confirm Change? dddddddddddddddddd...
  • Page 8 Assigning a telephone number (E.164) After restarting your telephone you have to assign a telephone number to your optiPoint 100 advance. The following display is shown: Change to "Service" 13:05PM bbbbbbbbbbb 07.02.01 > Only IP-dialing possiblebb > Call menu Service: Enter digit "6"...
  • Page 9 Operating without HiPath environment If you want to use your optiPoint 100 advance in a network without HiPath environment you have to switch off the "HiPath" function: > Change to "Service" 13:15PM bbbbbbbbbbb 07.02.01 1289 bbdddddddddddddddbbbb > Call menu Service: Enter digit "6"...
  • Page 10 Setting date and time If no SNTP server is accessible in your network environment, you have to set manually the time and date of your telephone: > Change to "Service" 13:15PM 07.02.01 1289b > Call menu > Change to "Configuration" Service: 1=Status? >...
  • Page 11 Setting language for operator prompting You can define your language for the display text of the telephone: > Change to "Service" 13:15PM 07.02.01 1289b > Call menu > Change to "Configuration" Service: 1=Status? > Call menu > Change to "Language" Configuration: 01=Country options? >...