To Service Personnel; About Lead-Free Solder - Yamaha DVR-S150 Service Manual

Home theater sound system
Hide thumbs Also See for DVR-S150:
Table of Contents

Advertisement

DVR-S150/NX-P150

TO SERVICE PERSONNEL

1. Critical Components Information
Components having special characteristics are marked Z
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
Meter impedance should be equivalent to 1500 ohm shunted
by 0.15µF.
WARNING: CHEMICAL CONTENT NOTICE!
The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or
plastic (where applicable) components may also contain traces of chemicals found by the California Health and
Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR
ANY REASON WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes
or expose eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands
before handling food.

About lead-free solder /

The P.C.B.s installed in this unit are soldered using the fol-
lowing solder.
Among some types of lead-free solder currently available, it
is recommended to use one of the following types for the
repair work.
• Sn + Ag + Cu (tin + silver + copper)
• Sn + Cu (tin + copper)
• Sn + Zn + Bi (tin + zinc + bismuth)
Caution:
1. As the melting point temperature of the lead-free solder
is about 30°C to 40°C (50°F to 70°F) higher than that of
the lead solder, be sure to use a soldering iron suitable to
each solder.
Downloaded From TheatreSystem-Manual.com Manuals
2
WALL
OUTLET
REFLOW
SMT
Side A
Solder Dip
Side B
FLOW
MI
EQUIPMENT
UNDER TEST
INSULATING
TABLE
Leakage current must not exceed 0.5mA.
Be sure to test for leakage with the AC plug in both
polarities.
Process
Process
AC LEAKAGE
TESTER OR
EQUIVALENT