Mitsubishi Electric PLA-RP·BA Technical Data Book page 44

Inverter split-type, heat pump air conditioners
Hide thumbs Also See for PLA-RP·BA:
Table of Contents

Advertisement

PSA-RP71GA
PSA-RP100GA
[LEGEND]
SYMBOL
NAME
P.B
INDOOR POWER BOARD
I.B
INDOOR CONTROLLER BOARD
FUSE
FUSE (T6.3AL250V)
ZNR
VARISTOR
CN2L CONNECTOR (LOSSNAY)
CN32 CONNECTOR (REMOTE SWITCH)
CN41 CONNECTOR (HA TERMINAL-A)
CN51 CONNECTOR (CENTRALLY CONTROL)
LED1
POWER SUPPLY (I.B)
LED2
POWER SUPPLY (R.B)
LED3
TRANSMISSION (INDOOR-OUTDOOR)
INDOOR UNIT
ORN
MF
ML
C
RED
I.B
LOUVER
FAN
POWER
1 3 5 7
1 3
(WHT)
CNL
CNDK
(YLW)
(RED)
X2
X6
X5
X4
X2
X6 X5 X4
LED3 LED2 LED1
SW2
SW1
SWE
ON
OFF
TH2
Refer to tables 1
and 2 for service PCB.
TH1
PSH -P.GAH
TH5
models only
2
HEATER
CN24
1
(YLW)
I.B
26H
RED
6
YLW
1
6
RED
5
88H
YLW
YLW
Table 1
SW2
MODELS
Service board
1 2 3 4 5
PSA-RP·GA
PSH-P·GAH
Table 2
SW2
MODELS
Service board
1 2 3 4 5
PSA-RP71GA
PSH-P71GAH
1 2 3 4 5
PSA-RP100GA
PSH-P100GAH
1 2 3 4 5
PSA-RP125GA
PSH-P125GAH
1 2 3 4 5
PSA-RP140GA
PSH-P140GAH
PSA-RP125GA
SYMBOL
I.B
SW1
SWITCH (MODEL SELECTION) See Table 1.
SW2
SWITCH (CAPACITY CODE) See Table 2.
SWE
SWITCH (EMERGENCY OPERATION)
RELAY (LOUVER)
X2
X4
RELAY (FAN MOTOR)
X5
RELAY (FAN MOTOR)
X6
RELAY (FAN MOTOR)
R.B
WIRED REMOTE CONTROLLER BOARD
TB6
TERMINAL BLOCK (REMOTE CONTROLLER
TRANSMISSION LINE)
HEATER
FS1,2
THERMAL FUSE (110°C16A)
H
HEATER
HEATER THERMAL SWITCH
26H
88H
HEATER CONTACTOR
P.B
CNSK
CN2S
(WHT)
(RED)
2
3
1
2
DC13.1V
1
POWER
1 3
1 3
1 2
CND
POWER
(ORN)
CN2D
(WHT)
CN51
ZNR
LIQUID
2
CN21
1
(WHT)
INTAKE
2
CN20
1
(RED)
PIPE
2
CN29
1
(BLK)
CN24
CN41
CN32
R.B
BLU
1
BLU
2
TB6
FS2
FS1
RED
RED
1
WHT
2
H
Notes:
1. SymboIs used in wiring diagram above are,
2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers
(S1, S2, S3) for correct wirings.
3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric
ON
wiring diagram for servicing.
OFF
4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of
230V), adopting superimposed system for power and signal.
1: If indoor and outdoor units have separate power supplies, refer to Fig.1.
2: For power supply system of this unit, refer to the caution label located near this diagram.
ON
OFF
ON
OFF
ON
OFF
ON
The black square (
) indicates
OFF
a switch position.
PSA-RP140GA
NAME
C
MF
ML
TB2
TB4
TH1
TH2
TH5
TB4
YLW
S1
TO
ORN
S2
OUTDOOR
S3
UNIT
1 (Fig.1)
1 3
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
WIRELESS
CN90
(WHT)
REMOCON
2
CN22
1
(BLU)
I.B
1
3
1
POWER
INDOOR/OUTDOOR
CN2L
CND
COMMUNICATION
(ORN)
CN3C
(BLU)
TRANSMISSION
WIRES DC12V
88H
TB2
5
3
RED
L
POWER SUPPLY
BLU
N
~(1 PHASE)
230V 50Hz
GRN/YLW
44
SYMBOL
NAME
CAPACITOR (FAN MOTOR)
FAN MOTOR
LOUVER MOTOR
TERMINAL BLOCK (HEATER) PSH-P
models only or option for PSA-RP
TERMINAL BLOCK
(INDOOR/OUTDOOR CONNECTING LINE)
ROOM TEMP.THERMISTOR
(0°C/15kΩ, 25°C/5.4kΩ DETECT)
PIPE TEMP.THERMISTOR/LIQUID
(0°C/15kΩ, 25°C/5.4kΩ DETECT)
COND./EVA.TEMP.THERMISTOR
(0°C/15kΩ, 25°C/5.4kΩ DETECT)
Please set the voltage using the
remote controller.
For the setting method, please refer to
the indoor unit Installation Manual.
TB2
L
RED
POWER SUPPLY
BLU
N
~(1PHASE)
230V 50Hz
GRY/YLW
TB4
RED
S1
BLU
S2
TO
OUTDOOR
S3
UNIT
3
: Connector,
: Terminal (block).
·
GAH
·
GA models.