FOR THE PLUMBER
CONNECT TO WATER
(observe local codes)
1
Usa
U"
(6.35
mm) OD soft copper
tubing
lor the
cold water
supply.
2
Prowde
a convement
manual
shut-oil
valve
I" the
water
llrw
3
Position
the rubmg
so it can enter
the access
hole
located
in the
rmht
hand
rear of rhe cabinet
The
tubing
should
eitend
beyond
the
cabinet
fronr
when
the cabinet
IS pushed
back
unto posft~on
See
Figure
5.
NOTE:
Always
purge
the water
lme before
maklng
the
final
connection
to the
inlet
of the water
valve
to prevent
possible
water
valve
malfunction
Alter
the cabinet
II in place,
bend
the tubing
to meet
the
connection
at the
water
valve.
The
garden
hose
threaded
compression
fitting
II found
in
the
parts
bag.
This
joint
provides
a conventent
dlrconnect
for
service.
Sa sure
the tubing
is clear
of compressor.
to
prevent
rattle.
CONNECT ME DRAIN
(observe locel codes)
The unit
is provided
wth
a gravity
drain
The ideal
installation
has a standpipe
(1 %".
32mm
minimum)
installed
directly
below
the outlet
or
the drain
lube.
Refer
lo Figure
5 (or the proper
location
of the standpipe.
It may bedeslrable
to insulate
drain
line thoroughly
up lo drain
inlet
4
FOR THE
ELECTRICIAN
ELECTRICAL
REQUIREMENTS
A 220/240
Volt, 50 Hz. 10 Amp (used electrical
supply
is required
(lime
delay
luse
or circuit
breaker
is
recommended).
It is recommended
lhat
a Separate
clrcuil,
serving
only
this appliance
be provided.
USE COPPER
WIRE
ONLY
RECOMMENDED
GROUNDING
METHOD
ELECTRICAL
GROUND
IS REGUIRED
ON
THIS
MACHINE
For your personal
salety
permanently
ground
this unit
in
accordance
with
applicable
local
codes
and
ordinances.
It is
recommended
that
a separate,
permanent
ground
connection
be made
lo the
unit
using
a green/yellow
colored,
insulated
conductor
ol
appropriate
size from
agrounded
cold waler
pip?:
a
grounded
lead in the service
panel
or a properly
driven
and electrically
grounded
ground
rod. Do not ground
lo a gas supply
pipe.
Do not connect
electric
power
supply
until unit is permanently
grounded.
Connect
the
ground
wire lo the approved
ground
and then connect
lo the metal
frame
01 the unit.
WIRING
CONFORM
TO NATIONAL
ELECTRICAL
CODE
CONFORM
TO ALL
LOCAL
CODES
AND
ORDINANCES
Remove
grill
mounting
screws
for access
to motor
comoartment
and
waler
connections.
Electrical
conriections
are made
lo the electrical
box which
is
located
al the rear or the machine.
Run permanent
type
1.6 mm d (#14) wiring
through
the hole provided
in the
eletrical
box to the line screws
on the terminal
board.
(See
Figure
6). DO NO USE
AN EXTENSION
CORD.
GROUND
TERMINAL
FIGURE
6