Note
If options 10, 11 or 17 are
set outside the SIA limits
while Option 69 is OFF, turn-
ing Option 69 ON will not
affect options 10, 11 or 17
until they are manually
changed.
Note
The panel clock must be set
to the correct time for this
option and Option 16: Auto
Phone Test to work correctly.
Note
This feature should be used
only if the panel experiences
consistent trouble reporting
to the central station. Other-
wise, leave this option off.
Simon Security System
Affected Option
Option 10: Entry Delay
Option 11: Exit Delay
Option 17: Dialer Delay
¾ To turn on SIA Limits, press:
Add—Option #—69—DONE.
¾ To turn off SIA Limits, press:
Delete—Option #—69—DONE.
* Not investigated for use by UL.

Option 70: Not Available

Option 71: Programming Report (Default = off)
Determines whether the panel sends a report to the central station anytime the pro-
gramming mode is entered/exited (on) or not at all (off).
The panel sends a report whenever the dealer (Utility 1) or installer (Utility 2) code is
used to enter programming mode and another report is sent when the programming
session ends (when the cover is closed).
¾ To turn on Programming Report, press:
Add—Option #—71—DONE.
¾ To turn off Programming Report, press:
Delete—Option #—71—DONE.
Option 72: Supervisory Time (Default = 12:00am)
Determines when the panel reports supervisory conditions (sensor failures) and auto-
matic phone tests to the central station.
¾ To set Supervisory Time, press:
Add—Option #—72—Hours—Minutes—DONE.
¾ To turn off (disable) Supervisory Time, press:
Delete—Option #—71—DONE.
Option 73: Modem Sensitivity (Default = off)
Determines whether the modem sensitivity is set to normal (off) or high (on).
¾ To turn on Modem Sensitivity, press:
Add—Option #—73—DONE.
¾ To turn off Modem Sensitivity, press:
Delete—Option #—73—DONE.
Option 74: Silent Panel Police Panic (Default = off)
Determines whether pressing the panel police panic button causes an audible (off) or
silent (on) alarm.
SIA Limits
SIA Limits
Factory Ranges
(Option 69 on)
(Option 69 off)
030-254 seconds
005-254 seconds
045-254 seconds
005-254 seconds
015-045 seconds
005-254 seconds
38