FUEL TANK CAPACITY
HITACHI Model
E24SC
E42SC, E62SC
Check the fuel and refill the tank if the fuel level is low. Refuel
carefully to avoid spilling fuel. Do not fill above the shoulder of
the fuel strainer.
Use unleaded gasoline with a pump octane rating of 86 or
higher.
The engine is certified to operate on unleaded gasoline.
Unleaded gasoline produces fewer engine and spark plug
deposits and extends exhaust system life. Never use stale or
contaminated gasoline. Avoid getting dirt or water in the fuel
tank.
Always keep the fuel strainer in place while refueling.

OPERATION

STARTING GENERATOR
WARNING: Before starting the generator, be sure that you read and understand all the safety and
operating instructions in this manual.
1. Disconnect all electrical loads from the generator.
2. Open ( "OPEN" / "O" )the fuel cock.
3. Push the engine switch to the ON/I position.
4. Set the choke lever to "CLOSE" (arrow mark). Not
necessary if the engine is warm.
5. Pull the starter handle slowly until resistance is felt.
This is the "Compression" point. Return the
handle to its original position and pull swiftly.
● Do not fully pull out the rope.
● After starting, allow the starter handle to return
to its original position while still holding the
handle.
● If the engine fails to start after several
attempts, repeat above procedures with choke
lever returned to "OPEN" position.
10
Liters
3.8
5.8
FUEL
FILTER
SCREEN
E24SC
E24SC
Fig. 9
E24SC
Fig. 11
E24SC
Fig. 13
E24SC
STARTER HANDLE
Fig. 15
LEVEL
(UPPER
LIMIT)
(Red line)
FUEL
LEVEL
FILTER
(UPPER
SCREEN
LIMIT)
E42SC, E62SC
Fig. 8
E42SC, E62SC
Fig. 10
E42SC, E62SC
Fig. 12
E42SC, E62SC
Fig. 14
E42SC, E62SC
STARTER HANDLE
Fig. 16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E42scE62sc

Table of Contents