Table of Contents

Advertisement

OWNER'S MANUAL
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : AC Smart II
Advanced Control Smart
www.lg.com
P/NO : MFL62077702

Advertisement

Table of Contents
loading

Summary of Contents for LG V-NET AC Smart II Advanced Control Smart

  • Page 1 OWNER’S MANUAL Please read this manual carefully before operating your set and retain it for future reference. TYPE : AC Smart II Advanced Control Smart www.lg.com P/NO : MFL62077702...
  • Page 2: Table Of Contents

    AC Smart TABLE OF CONTENTS 1. AC SMART II Introduction.......1-1 AC Smart II characteristics ....................1-1 AC Smart II exterior......................1-3 AC Smart II components ....................1-5 AC Smart II products specifications ................1-6 2. AC Smart II Installation ........2-1 Before installing AC Smart II..................2-2 Setting unit address......................2-3 Setting PI485 and connectiong line................2-4 •...
  • Page 3 4. AC SMART II Menu ..........4-1 Examine control/monitoring information..............4-2 • Zone, group and unit status display ................4-2 • Zone, group and unit monitoring ..................4-6 • Zone, group and unit control ..................4-13 Control/Monitoring......................4-16 • Controlling the unit .....................4-16 • Controlling the unit in detail ..................4-20 5.
  • Page 4 7. History Menu............7-1 Browsing specific history ....................7-2 Remove all error records....................7-5 8. Statistical Menu ..........8-1 Accumulative operating time ..................8-2 • Searching accumulative operating time ...............8-3 Monthly operating time....................8-4 • Searching monthly operating time................8-5 Setting the operating time search condition ..............8-6 Saving operating time report file ...................8-8 9.
  • Page 5 10. Environment Setting ........10-1 Checking the S/W version information ...............10-2 Password setting ......................10-3 Language setting ......................10-5 Screen saver setting ....................10-7 Alarm setting ......................10-10 Changing the temperature display ................10-12 Time setting ........................10-14 Screen calibration ......................10-16 11. Introduction to Advanced Environment setting ..11-1 Network information setting ..................11-2 Remote service setting ....................11-3 •...
  • Page 6: Safety Precautions

    Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
  • Page 7 Safety Precautions While re-installing the Do not use the power cord Do not disjoint randomly or established product, notify near Flammable gas or repair and remodel the the service center or combustibles, such as product. establishment specialty gasoline, benzene, thinner, store.
  • Page 8 Safety Precautions Do not put firearms near Do not put an electric heater Do not spill water inside product. or conductor near to the product. product. • It can cause fire. • It can cause fire and electric • It can cause electric shock and shock.
  • Page 9 Safety Precautions CAUTION ■ During usage Clean by soft hands using a Use touch screen with a pen Do not place any live part on cleaning material like a soft that product offers. the surface having water. cloth. • It can result in fire and product •...
  • Page 10: Ac Smart Ii Introduction

    1. AC SMART II Introduction 1. AC SMART II Introduction AC Smart is the central controller that can manage maximum of 64 air conditioner indoor units within one space individually or in integrated manner. AC Smart can monitor or control the operation of the air conditioner and ventilator installed in each room of the building from one location, such as an administrative office of the building.
  • Page 11 1. AC SMART II Introduction Managing the automatic schedule operation & Saving the energy The AC Smart can automatically run the air conditioner by setting the schedule. When you register the schedule for a specific period by this schedule function, the\ unnecessary operation of the air conditioner can be reduced and the energy can be efficiently saved.
  • Page 12: Ac Smart Ii Exterior

    1. AC SMART II Introduction AC SMART II exterior AC Smart is composed in the following shape. Backlight button and keyboard button Stylus pen and stylus pen holder Control panel 217mm Option card slot (reserved) RESET BUTTON USB PORT (only for SVC & Spare) Note: Using the external button to compensate the screen The screen compensation function can be executed by pressing the keyboard button at the top of the AC Smart and then the backlight button.
  • Page 13: Reset Button

    1. AC SMART II Introduction Backlight button This is the button to turn on and off the LCD backlight of AC Smart. When you do not use AC Smart II for a long period of time, it is good to turn off the backlight to extend the life of the LCD backlight. Keyboard button This is the button to display or hide the keyboard on the screen so that the user can enter the characters.
  • Page 14: Ac Smart Ii Components

    1. AC SMART II Introduction AC Smart II components The components of AC Smart are as follows inside the box. Open the box of AC Smart and check whether all components are included. AC Smart II Power adapter Quick Guide Power cord Manual CD AC Smart...
  • Page 15: Ac Smart Ii Products Specifications

    1. AC SMART II Introduction AC Smart II product specifications The product specifications of AC Smart are as follows. Item Specifications MP2530F(or MP2531F) - Dual CPU[ARM926E/360MHz + ARM946E/300MHz Memory 128MB [DDR 64MB(A Bank) + DDR 64MB(B Bank)] 512MB (NAND Flash) Boot ROM &...
  • Page 16: Ac Smart Ii Installation

    2. AC Smart II Installation 2. AC Smart II Installation This chapter describes the installation method to use AC Smart II. Caution: AC Smart installation Installation of AC Smart requires special technology. Therefore, The installation detail mentioned in this chapter must be executed by an installation technician with installation qualifications.
  • Page 17: Before Installing Ac Smart Ii

    Information: Maximum permitted communication length and specification The maximum permitted communication length that LG Electronics guarantee is 1,000m. In other words, the unit installed the farthest from AC SMART II must be installed within 1,000m distance. It is recommended to use the communication cable of 0.75mm (Shield) or above.
  • Page 18: Setting Unit Address

    2. AC Smart II Installation Setting unit address First, you must assign the address to each unit so that the address of each unit (Indoor unit, ventilator, Eco V DX , On/Off, AWHP) is not duplicated by considering the overall installation composition connected to AC Smart II.
  • Page 19: Setting Pi485 Dip Switch

    2. AC Smart II Installation Setting PI485 and connecting line After setting the address of the unit, you must install PI485 and set the DIP switch. And then you must connect the RS485 line to communication with AC Smart II. Reference: PI485 installation The installation of PI485 may differ by the product of the outdoor unit.
  • Page 20 2. AC Smart II Installation Reset switch Set the DIP switch as follows depending on the type of outdoor unit PI485 is attached to. DIP switch Setting Product type - Multi V product (Excluding CRUN, LRA product) ON: 1, 4 - MPS static speed product with common PCB applied OFF: 2, 3, 5, 6, 7, 8...
  • Page 21 2. AC Smart II Installation Information: Checking PI485 DIP switch setting You can check whether the indoor unit address setting and the DIP switch setting of PI485 have been set correctly as follows. • LED01G will flash for as many as the connected number of indoor units. •...
  • Page 22: Setting Individual Lock Function

    2. AC Smart II Installation Setting individual lock function AC SMART II provides the lock function through the central control to disable individual control of operating mode, fan level and temperature of the indoor unit. To use this lock function, you must connect the 2PIN connector to the CN_DRY of PI485 or set DIP switch #5 to On depending on the outdoor unit product type.
  • Page 23 2. AC Smart II Installation The following picture shows an example of the central control method when the 2PIN connector is connected to the CN_DRY terminal or when the DIP switch #5 is set to ON. 1) Through the central controller, such as AC Smart, you can command the 'Cool operation, 20°C setting, high fan level, temperature lock' function.
  • Page 24: Connecting Pi485 To Rs485 Line

    2. AC Smart II Installation Connecting PI485 to RS485 Line To connect PI485 and AC Smart, two RS485 lines must be connected to BUS_A and BUS_B of PI485. Refer to the following figure to connect the RS485 line. Reference: Connecting RS485 cable to PI485 The shape of PI485 can differ by the number.
  • Page 25 2. AC Smart II Installation The following figure is an example of several units of PI485 connected to AC Smart. BUS_A BUS_B AC Smart II 2-10 Installation/Owner's Manual...
  • Page 26 2. AC Smart II Installation Information: RS485 connection of AC SMART II Maximum of 64 indoor units can be connected to one AC SMART II, and when the expansion kit is installed, maximum of 128 indoor units can be connected. If there are many number of outdoor units to connect, the outdoor unit must be connected in BUS format.
  • Page 27 2. AC Smart II Installation Information: Connection setting when using simple central controller with AC Smart You can use a simple central controller with AC Smart. When you want to use a simple central controller with AC Smart, connect the simple central controller in the order shown as follows. Reference: Check V-net Label Check the V-net Lbel on the right side of the case of the simple central controller.
  • Page 28: Installing Ac Smart Ii And Connecting Line

    2. AC Smart II Installation Installing AC SMART II and connecting line After setting PI485, install AC Smart and connect the RS485 line for communication with PI485. To install AC Smart and connect the line, proceed as follows. Reference: AC Smart II installation AC Smart is designed to be basically installed on the wall.
  • Page 29 2. AC Smart II Installation . Pull out the RS485 cable through the hole of the rear panel and connect it to the socket. Use the ʻ-ʻ driver to connect the two RS485 communication cable as follows. RS485 - RX (BUS-B) RS485 - TX (BUS-A) Caution: RS485 communication cable connection When connecting the RS485 communication cable, be careful not to mix the polarities...
  • Page 30 2. AC Smart II Installation . To use the network related function provided by AC SMART II (Emaion transmission, SVCNet connection), the UTP cable must be connected. Connect the UTP cable that can be connected to the Internet on the rear side of the main unit of AC SMART II to the LAN port.
  • Page 31 2. AC Smart II Installation . Assemble the main unit of AC Smart on the rear penal installed on the wall. After hanging the top holes of the top of the main unit to the top of the rear panel, push forward and slide in the bottom of the main unit.
  • Page 32: Logging In Of Ac Smart Ii

    When the power is applied to the AC Smart, the AC Smart automatically operates. When the AC Smart II operates, the LG logo screen is initially displayed and then chanted to the login screen. The AC Smart II can be logged in with three method such as professional, administrator and general...
  • Page 33 2. AC Smart II Installation . The password is ʻdigital21ʼ which cannot be changed. When you correctly enter the password and press [OK] button, you are logged in and can set all functions of the AC Smart. After enter 'digital21', press [OK] button .
  • Page 34: Registering The Unit

    2. AC Smart II Installation Registering the unit After connecting PI485 to AC Smart, you must operate AC Smart to register the unit the address has been set to. You can register the unit in 2 methods to AC Smart. •...
  • Page 35 2. AC Smart II Installation . When you select the ʻDevice management menu, the following screen will be displayed. Press the [Unit Reg] button located on the bottom right side. Click on [Unit Reg] button . ʻDevice registrationʼ screen will be displayed. When you press the [Auto] button, the ʻConfirmationʼ screen to check the execution of auto setting will be displayed.
  • Page 36 2. AC Smart II Installation . The process to search for and register the indoor unit and the ventilator connected to the AC Smart II proceeds. When this process is finished, the registered unit is added and displayed at the table located at the bottom of the screen.
  • Page 37 2. AC Smart II Installation . Finally, the temporarily saved unit setting should be registered to the system. When [Save] button is pressed, ʻInformationʼ screen to check whether to apply the current setting to the system is displayed. Press [Yes] button. To apply to system, click on [Save] button click on [Yes] button .
  • Page 38: Directly Registering The Unit

    2. AC Smart II Installation Directly registering the unit You can directly register the unit connected to AC Smart. To register the unit, proceed in the order as follows. . After logging in as installation professional to AC SMART II, select the ʻDevice managementʼ menu from the menu.
  • Page 39 2. AC Smart II Installation . ʻUnit Registrationʼ screen is displayed to register a unit. Enter the unit information and press [Add] button. See the following table for the information to enter. After entering unit information, click on [Add] button Item Description Enter the type of unit...
  • Page 40 2. AC Smart II Installation . The information of the added unit is displayed in the table. Register all the units to add by repeating the same procedure. To save the registered units, click on the [OK] button. Click on [OK] button to apply to system .
  • Page 41 2. AC Smart II Installation . Finally, the temporarily saved unit setting should be registered to the system. When [Save] button is pressed, ʻConfirmʼ screen to check whether to apply the current setting to the system is displayed. Press [Yes] button. [Click on [Save] button to apply to system .
  • Page 42: Setting The Emergency Stop Interlocking

    2. AC Smart II Installation Setting the emergency stop interlocking AC Smart has an emergency stop interlocking that stops all the indoor units and ventilators set in case of a fire or any other emergency situation. You can use the emergency stop function by connecting the external fire detection sensor to the connection terminal of external non-contact point method on the rear side of AC Smart II as shown below.
  • Page 43: Ac Smart Ii Menu

    3. AC Smart II Menu 3. AC Smart II Menu This chapter describes the AC SMART II menu and screen configuration to operate AC SMART II. AC SMART II screen configuration When you log in to AC SMART II, the menu selection screen is displayed. Log out button AC Smart II menu...
  • Page 44 3. AC Smart II Menu When the user selects a specific function, the execution screen of the applicable function is displayed. The example of Control/Monitoring menu is used hereafter. Home button Log out button Function execution screen Message window Home button When you press the Home button, it will switch to the menu selection screen of AC SMART II.
  • Page 45: Ac Smart Ii Information Entry Method

    3. AC Smart II Menu AC SMART II information entry method AC SMART II uses the touch screen method to have the user enter the information, and provides the software keyboard (Keyboard) to enter the character. Software keyboard (Keyboard) Generally in situations to enter the character, the software keyboard is automatically displayed on the screen.
  • Page 46: Logging On Ac Smart Ii

    When the power is applied to the AC Smart, the AC Smart automatically operates. When the AC Smart operates, the LG logo screen is initially displayed and then chanted to the login screen. The AC Smart can be logged in with three method such as professional, administrator and general...
  • Page 47: Logging In As Installation Professional

    3. AC Smart II Menu Logging in as installation professional To login as installation professional, proceed as follows. . Press the top left part of the log in screen for more than 5 seconds, and the software keyboard and password entry screen are displayed. Software keyboard When you press this for 5...
  • Page 48: Logging In As Administrator

    3. AC Smart II Menu Logging in as administrator To log in as administrator, proceed as follows. . When you press the ʻAdministratorʼ button, the software keyboard and password entry screen will be displayed. Software keyboard Press Administrator] button to display the password input screen .
  • Page 49: Logging In As General User

    3. AC Smart II Menu Logging in as general user To log in as a general user, proceed as follows. . When you press ʻGeneral userʼ button, it is directly logged into the AC Smart with no password input procedure. If pressing general user button, Log-In without input password .
  • Page 50: Ac Smart Ii Menu

    4. AC Smart II Menu 4. AC Smart II Menu Control/Monitoring is the menu for the user to manage multiple units that can be commonly controlled as a group. There are 5 types of units that can be controlled. Ventilator : Unit that maintains clean air through air circulation. Eco V DX : Ventilation Unit that combine to function of indoor unit.
  • Page 51: Examine Control/Monitoring Information

    4. AC Smart II Menu Examine control/monitoring information This chapter explains a variety of information provided from Control/Monitoring menu. Zone, group, and unit status display Status display of zone, group and unit Control/Monitoring menu displays the status of Zone, Group or Unit (Indoor unit, ventilator, Eco V DX, On/Off, AWHP) through the following icons.
  • Page 52 4. AC Smart II Menu Unit operating mode display AC SMART II displays the operating mode of each unit as the following icon. When you set the information display format to ʻIconʼ, the screen will be displayed as follows. Unit type Icon Description Icon...
  • Page 53 4. AC Smart II Menu Unit alarm display AC SMART II shows the current alarm through the following icons. Here, the indoor unit among various types of units is used as an example. When you set the information display format to ʻIconʼ, it will be displayed as follows. Alarm Description Alarm...
  • Page 54 4. AC Smart II Menu In the Table format, the following information is displayed according to the selection of Zone, Group and Unit. Type Item Description Name of selected Zone or Group is displayed. Name Number of units Total number of units is displayed. Number of units in Number of units in operation is displayed.
  • Page 55: Zone, Group And Unit Monitoring

    4. AC Smart II Menu Type Item Description Individual lock function of unit is displayed. Individual lock function is the function to disable particular functions individually so that the user cannot individually control the unit where it is installed indoors. Individual lock •...
  • Page 56 4. AC Smart II Menu The information shown as the condition information is as follows. Display item Description Average indoor temperature of installed indoor units is displayed. Average indoor Indoor unit not in operation and indoor unit with communication error (Code: temperature 242) and expansion kit error (Code: 251) are excluded from the measurement of average indoor temperature.
  • Page 57 4. AC Smart II Menu Indoor unit monitoring information Indoor unit monitoring information shows the current indoor temperature and indoor unit setting. In case of communication error or expansion kit error, other information except for the alarm is not displayed. <Indoor unit monitoring tab>...
  • Page 58 4. AC Smart II Menu Item Description Wind direction setting status is displayed. - ON: When it is set for the direction of the wind to move up and down Wind direction - OFF: When it is set for the direction of the wind to blow in one direction Lock function setting status to disable all functions of each unit so that the user cannot control the units via remote controller is displayed.
  • Page 59: Ventilator Monitoring Information

    4. AC Smart II Menu Ventilator monitoring information Ventilator monitoring information shows the current operating mode and setting. In case of communication error or expansion kit error, other information except for the alarm is not displayed. <Ventilator monitoring tab> When you press the [View detail] button, the ʻVentilator conditionʼ...
  • Page 60 4. AC Smart II Menu On/Off unit monitoring information On/Off unit monitoring information displays the current operating condition. In case of communication error, other information excluding the alarm is not displayed. <On/Off unit monitoring tab> Information displayed on On/Off unit monitoring tab is as follows. Item Description Operation...
  • Page 61 4. AC Smart II Menu Information displayed on AWHP unit monitoring tab is as follows. AWHP unit displays the following information only through separate installation and setting. Item Description Currently set indoor temperature is displayed. When the control temperature is Air set temperature set to air temperature, this item is displayed.
  • Page 62: Indoor Unit Control

    4. AC Smart II Menu Zone, Group and Unit control ʻControlʼ tab is located at the bottom of the Control/Monitoring menu. The control tab has the menu to directly control the Zone, Group and units. The control of the Zone and Group, and the control of the units is displayed differently.
  • Page 63 4. AC Smart II Menu Caution: Temperature lock (4-9) When you have transmitted the temperature lock command at the temperature exceeding the set range of the desired temperature, the unit may not operate normally to the set temperature. Therefore, please set the temperature lock to the temperature within the set range of the desired temperature.
  • Page 64 4. AC Smart II Menu AWHP unit control When you select the AWHP unit from the Control/Monitoring screen, the control tab is displayed as follows, and you can directly control the AWHP unit function. For the AWHP unit, you can select the air/water temperature as the control temperature with the remote controller.
  • Page 65: Control/Monitoring

    4. AC Smart II Menu Control/Monitoring This section describes how to operate the AC Smart function in order by using the control/monitoring menu. Controlling the unit The function of the unit to control is as follows. • Indoor temperature setting of unit •...
  • Page 66 4. AC Smart II Menu . Press the button for each function and then press the [Apply] button. Refer to the following chart of the description of each function. Press the control tab to set the function and then press the [Apply] button [Indoor unit setting item] (4-8) Item Description...
  • Page 67 4. AC Smart II Menu Item Description Run: This operates the unit. Power Stop: This stops the unit. When you press this button, you can set the control of the indoor unit in detail. Advanced Refer to ʻControlling the unit in detailʼ in the next section. [Ventilator setting item] Item Description...
  • Page 68 4. AC Smart II Menu [On/Off unit setting item] Item Description You can turn On/Off the unit connected to AC SMART II. Operation • [Operate]: Operate the On/Off unit. • [Stop]: Stop the On/Off unit. [AWHP unit setting item] Item Description You can set the indoor air temperature.
  • Page 69: Controlling The Unit In Detail

    4. AC Smart II Menu Controlling the unit in detail You can set detail control function of the unit. To set the function of unit in detail, proceed according to the following description. Control method of the Zone is described as the example here. Reference: Detail control of Zone, Group and Unit Detail control screens for Zone, Group and Unit are different.
  • Page 70 4. AC Smart II Menu . 'Detail control' screen is displayed. After clicking on the button of the function to set, click on the [OK] button. Refer to the following chart for the description of each function. [Indoor Unit] Item Description The user can set the desired indoor temperature.
  • Page 71 4. AC Smart II Menu Item Description - Med: This sets the fan speed to med. - High: This sets the fan speed to high. Fan level - Auto: This sets to automatically measure the indoor level of contamination and maintain the optimal condition. Set whether rotate the fan automatically.
  • Page 72 4. AC Smart II Menu Item Description This sets the fan speed of the ventilator. You can adjust the level by considering the indoor level of contamination. - Low: This sets the fan level to low. - High: This sets the fan level to high. Fan level - Super: This sets the fan level to maximum speed.
  • Page 73 4. AC Smart II Menu [AWHP unit setting item] Item Description You can set the indoor air temperature. Air temperature Water temperature Set the water temperature that goes through AWHP unit. Heat tank You can set the water temperature within the hot water tank. temperature You can operate/stop the AWHP unit.
  • Page 74: Schedule Menu

    5. Schedule menu 5. Schedule menu Schedule is the function to execute the reserved operation at specific time by predesignating the operation of the air conditioner. AC Smart, you can set the group to commonly apply the schedule. Also by introducing the pattern concept, you can easily apply the repeated schedule in week or day unit.
  • Page 75: Manage Schedule Group

    5. Schedule menu 1. Edit schedule group Create/Edit the schedule group through group edit. 2. Edit schedule pattern You can create/edit the weekly/daily schedule through schedule pattern wizard. 3. Set schedule through schedule wizard Apply the schedule pattern and operating period to the schedule group through schedule wizard. 4.
  • Page 76: Creating New Schedule Group

    5. Schedule menu Creating new schedule group To create a new schedule group, proceed in the following order. . Select the 'Schedule' menu from the menu of AC Smart. When you select the 'Schedule' menu, the following schedule screen is displayed. To create a new schedule group, click on the [Edit group] button.
  • Page 77 5. Schedule menu . After entering the name of the schedule group to create, click on the [OK] button. After entering the group name, click on [OK] button . Check whether the applicable schedule group has been created in 'Group'. Now, select the unit to be added to the schedule group from the unit list on the right, and press the [ ] button to add to the schedule group.
  • Page 78 5. Schedule menu . Click on the [Save] button to save the current setting. 'Information' screen to confirm the saving process is displayed. Press the [Save] button to save the setting AC Smart...
  • Page 79 5. Schedule menu Information: Schedule group setting using the basic group setting button When you click on the [Basic group setting] button located at the bottom left corner of the ʻEdit groupʼ screen, you can create the same group as the basic control group set for control and monitoring from the ʻSettingʼ...
  • Page 80: Rename Schedule Group

    5. Schedule menu Rename schedule group To rename the schedule group, proceed in the following order. . Select the 'Schedule' menu from the menu of AC Smart. When you select the 'Schedule' menu, the following schedule screen is displayed. To rename the schedule group, click on the [Edit group] button.
  • Page 81 5. Schedule menu . After entering the name of the schedule group to change, click on the [OK] button. After entering the schedule group name, click on [OK] button . Check whether the name of the applicable schedule group has changed in 'Group', and click on the [Save] button to save the current setting.
  • Page 82: Deleting Schedule Group

    5. Schedule menu Deleting schedule group To delete the schedule group, proceed in the following order. . Select the 'Schedule' menu from the menu of AC Smart. When you select the 'Schedule' menu, the following schedule screen is displayed. To delete the schedule group, click on the [Edit group] button.
  • Page 83 5. Schedule menu . Check whether the applicable schedule group has been deleted from 'Group', click on the [Save] button to save the current setting. Check whether schedule group is deleted clicking on [Save] button 5-10 Installation/Owner's Manual...
  • Page 84: Creating Schedule Pattern

    5. Schedule menu Creating schedule pattern Schedule pattern refers to a certain operation of unit (Indoor unit, Ventilator, On/Off unit, AWHP unit) repeated for each day or week. Schedule pattern wizard is the process of configuring the operation of the unit in weekly or daily pattern.
  • Page 85: Adding Weekly Schedule Pattern

    5. Schedule menu Adding weekly schedule pattern To add the weekly schedule pattern, proceed as follows. . When you select the "Schedule" menu from the initial screen of AC SMART II, the following screen will be displayed. To create a schedule pattern, press the [Schedule pattern wizard] button. Press [Schedule pattern wizard] button .
  • Page 86 5. Schedule menu . Select "Add schedule pattern" and press the [Next] button. Select "Add schedule pattern", and press the [Next] button Reference: Edit weekly schedule pattern When editing the weekly schedule pattern, select the weekly schedule pattern to edit and select "Edit weekly pattern".
  • Page 87 5. Schedule menu . Enter the name of the weekly schedule pattern, and press the [Next] button. Enter the weekly schedule pattern name and press the [Next] button . Select the time to operate the unit from "Select time" or "Schedule time" item. Set the unit operation from "Control setting"...
  • Page 88 5. Schedule menu Item Description You can set the desired indoor temperature. Set temperature You can set the operation and stopping of the ventilator. Operation - Run: You can operate the ventilator. - Stop: You can stop the operation of the ventilator. You can set the operating mode of the indoor unit.
  • Page 89 5. Schedule menu . When you press the [Apply schedule] button, the schedule will be added to the table. If there are additional schedules planned, repeat the above process to additionally set the schedule. When the schedules are all set, press the [End] button. Press the [Apply schedule] button to add the schedule.
  • Page 90 5. Schedule menu . Message saying that the schedule pattern edit is completed is displayed. Press the [OK] button to complete the editing. Press the [OK] button to end the wizard 5-17 AC Smart...
  • Page 91: Adding Daily Schedule Pattern

    5. Schedule menu Adding daily schedule pattern To add the daily schedule pattern, proceed as follows. . When you select the "Schedule" menu from the initial screen of AC SMART II, the following screen will be displayed. To create a schedule pattern, press the [Schedule pattern wizard] button. Press the [Schedule pattern wizard] button .
  • Page 92 5. Schedule menu . Select the "Add schedule pattern", and press the [Next] button. Select the "Add schedule pattern" and press the [Next] button Reference: Edit daily schedule pattern When editing the daily schedule pattern, select the daily schedule pattern to edit and select "Edit daily pattern".
  • Page 93 5. Schedule menu . Enter the daily schedule pattern name, and press the [Next] button. Enter the daily schedule pattern name and press the [Next] button . Select the time to operate the unit from "Select time" or "Schedule time" item. Set the unit operation from "Control setting"...
  • Page 94 5. Schedule menu Item Description Set temperature You can set the desired indoor temperature. You can set the operation and stopping of the ventilator. Operation - Run: You can operate the ventilator. - Stop: You can stop the operation of the ventilator. You can set the operating mode of the indoor unit.
  • Page 95 5. Schedule menu . When you press the [Apply schedule] button, the schedule will be added to the table. If there are additional schedules planned, repeat the above process to additionally set the schedule. When the schedules are all set, press the [End] button. Press the [Apply schedule] button to add the schedule.
  • Page 96: Setting The Schedule Pattern In Detail

    5. Schedule menu Setting the schedule pattern in detail When adding/editing the weekly and daily schedule pattern, you can set the detail operation of each unit by setting the detail schedule. . In stage 4 of the weekly or daily schedule pattern wizard, press the [Advanced] button. Stage 4 of schedule pattern wizard Press the [Advanced] button .
  • Page 97 5. Schedule menu [Indoor unit schedule setting item] Item Description Set temperature You can set the desired indoor temperature. You can set the operation and stopping of the indoor unit. Operation - Run : It operates the indoor unit. - Stop: It stops the operation of the indoor unit.. You can set the operating mode of the indoor unit.
  • Page 98 5. Schedule menu [Ventilator schedule setting item] Item Description You can set the operation and stopping of the ventilator. Operation - Run: You can operate the ventilator. - Stop: You can stop the operation of the ventilator. You can designate the operating mode of the ventilator. - Heat: Both inlet/outlet go through heat exchange device for ventilation.
  • Page 99 5. Schedule menu Item Description - Disable power save: This disables the power save function. - Enable quick operation: This enables the unit to operate in maximum performance to prevent the expansion of contaminated indoor air or humidity User mode to other space.
  • Page 100 5. Schedule menu [On/Off unit schedule setting item] Item Description You can turn On/Off the unit connected to AC SMART II. Operation • [Operate]: Operate the On/Off unit. • [Stop]: Stop the On/Off unit. [AWHP unit schedule setting item] Item Description You can set the indoor air temperature.
  • Page 101: Applying The Schedule

    5. Schedule menu Applying the schedule Schedule refers to the designation of operation during the applicable time period by adding the units (Indoor unit, Ventilator, Eco V DX, On/Off unit, AWHP unit) to the schedule group and schedule pattern. AC SMART II provides the schedule wizard to make the schedule application easy. Schedule wizard is composed of 6 stages as shown below.
  • Page 102 5. Schedule menu To apply the schedule, you must proceed as follows. . When you select the "Schedule" menu from the initial screen of AC SMART II, the following screen will be displayed. To apply the schedule, press the [Schedule wizard] button. Press the [Schedule wizard] button .
  • Page 103 5. Schedule menu . Select "Add schedule" and press the [Next] button. Select "Add schedule" and press the [Next] button Information: Editing schedule period and deleting schedule In stage of schedule wizard, you can edit the applied period of the existing schedule and delete the existing schedules.
  • Page 104 5. Schedule menu . When you press the button, the calendar is displayed. Use the calendar to select the period (Start date, End date). After the entry, press the [Next] button. 1. Use the calendar to enter the start and end date 2.
  • Page 105 5. Schedule menu . Check the current schedule setting information. Also you can add a new schedule or add/delete set schedule. After checking the schedule information, press the [Next] button. 1. Check and edit schedule information Press the [Next] button Reference: Schedule edit When editing the schedule, the setting for the input item is the same as that of schedule pattern.
  • Page 106 5. Schedule menu Reference: Exception day setting Exception day setting is not a mandatory entry item. If you do not need the exception day, press the [End] button to end the schedule setting. . When you see the screen to enter the name of exception day, enter the name of the exception day, and press the [OK] button.
  • Page 107 5. Schedule menu Information: Renaming/Deleting exception day In the exception day edit screen, you can rename or delete the exception day. To rename the exception day, select the name of the exception day and press the [Rename] button to enter the new name. To delete the exception day, select the exception day and press the [Delete] button .
  • Page 108 5. Schedule menu Information: Copying the schedule You can copy the schedule set for a schedule group to a schedule of another schedule group. . Select the "Copy schedule between groups" item from the schedule wizard start screen, and press the [Next] button. Select the "Copy schedule between groups"...
  • Page 109: View The Schedule

    5. Schedule menu Viewing the schedule Schedule view tab is the first screen to be displayed when the user selects the schedule menu. From the schedule view screen, you can check the details of the schedule applied to a specific schedule group.
  • Page 110 5. Schedule menu To check or edit the schedule detail, proceed as follows. . Press the ʻViewʼ tab from the schedule menu. When you select the schedule group and period to check, you can check the schedule. When you select the schedule group and period, you can check the schedule Information: View schedule detail...
  • Page 111 5. Schedule menu . To edit the applied schedule, press the [Edit schedule] button located at the top right corner of the screen. When the schedule wizard screen is displayed, you can edit the existing schedule. After editing the schedule, press the [End] button to end editing the schedule. 1.
  • Page 112: Running/Stopping The Schedule

    5. Schedule menu Running/Stopping the schedule You can run/stop the schedule applied to the Group from the schedule run/stop tab. You can select to stop the schedule of individual or all group. You can select the group to stop when stopping the schedule by group.
  • Page 113 5. Schedule menu . When running the schedule by Group, select the ʻRun schedule by Groupʼ item and mark ʻ√ʼ next to the schedule group to run. If you want to stop all schedules, select the ʻStop all Group scheduleʼ button.
  • Page 114: Auto Control Menu

    6. Auto control menu 6. Auto control menu The AC Smart can automatically control the Indoor unit, ventilator, Eco V DX, On/Off, AWHP interconnected via the network with various methods. Auto control menu provides 3 functions, as follows, as the auto control function. •...
  • Page 115: Creating Operating Group

    6. Auto control menu Managing operating group In auto control, you must create/apply each group for the temperature limit operation, auto change over operation and time limited operation. Reference: Temperature limit operation and auto change over operation group setting criteria Temperature limit operation and auto change over operation are functions targeted only to the indoor units.
  • Page 116 6. Auto control menu Reference: Location of edit button for temperature limit operation and auto change over operation group For the temperature limit operation and auto change over group, the [Edit group] button is located at the bottom right side of the screen. .
  • Page 117 6. Auto control menu . Enter the name of the group to create and press the [OK] button. After entering the group name, press the [OK] button . Check whether the applicable operating group has been created for the ʻGroup nameʼ. Now select the unit to include in the newly created group from the unregistered unit list, and press the [◀] button to move to the registered unit list.
  • Page 118 6. Auto control menu . Press the [Save] button to save the setting. When creating the group is completed, it will return to the previous screen. Press the [Save] button AC Smart...
  • Page 119 6. Auto control menu Information: Setting the operating group to basic group When you press the [Set basic group] button located at the top right side of the screen, you can create the same operating group as the basic control group you set in control and monitoring from the "Unit management"...
  • Page 120: Deleting The Operating Group

    6. Auto control menu Deleting the operating group To delete the operating group, proceed as follows. . Press the [Edit group] button located at the bottom of ʻAuto controlʼ screen. Press the [Edit group] button . ʼEdit groupʼ screen is displayed. Select the operating group to delete and press the [Delete] button. The applicable group will be deleted.
  • Page 121 6. Auto control menu . Verify if corresponding drive group is created at 'group name'. Then, select the device to be included at created group from un-registered device list and move it to registered device list by pressing [◀ ] button. Check whether the group is deleted Press the [Save] button Installation/Owner's Manual...
  • Page 122: Renaming The Operating Group

    6. Auto control menu Renaming the operating group To rename the operating group, proceed as follows. . Press the [Edit group] located at the bottom of the ʻAuto controlʼ screen. Press the [Edit group] button . ʻEdit groupʼ screen is displayed. Select the group to rename and press the [Rename] button. ʻRename groupʼ...
  • Page 123 6. Auto control menu . After entering the name of the operating group to change, press the [OK] button. After entering the group name, press the [OK] button Check whether the name of the applicable group has been changed in the ʻGroup nameʼ, and press the [Save] button to save the setting.
  • Page 124: Temperature Limit Operation

    6. Auto control menu Temperature limit operation Temperature limit operation is the function to maintain the temperature of the space where the air conditioner is installed within a certain temperature range (+4°C ~ -4°C). AC SMART II can automatically control the indoor temperature so that the temperature does not exceed the range based on the upper/low limit temperature set by the user and the current indoor temperature.
  • Page 125 6. Auto control menu When you press the temperature limit operation tab from the auto control menu, the following screen to set the temperature limit operation will be displayed. The group that has been set up for the temperature limit operation and the details of the setting are displayed in table format.
  • Page 126: Setting Temperature Limit Operation

    6. Auto control menu Setting temperature limit operation To set the temperature limit operation function, proceed in the following order. . Select 'Auto control' menu from the menu of AC Smart. When you select the 'Auto control' menu, the following auto control screen is displayed. Click on the [Set option] button. Click on [Set option] button .
  • Page 127 6. Auto control menu Item Description Name of temperature limit operation group is displayed. Group name This sets the minimum to execute the temperature limit operation. The Low Temp. temperature range that can be set is 1°C~16°C. This sets the maximum temperature to execute the temperature limit High Temp.
  • Page 128 6. Auto control menu . It is saved. When the setting is saved, the [Save] button will be deactivated and will be reactivated when the current information changes. Click on the [Close] button to move to the prior screen. Click on [Close] button to return to prior screen .
  • Page 129 6. Auto control menu . After setting up non-work time, non-operating to select a start time and end time. . When you have completed all the setting, click on the [Save] button. The ʻInformationʼ screen to ask to save will be displayed. Click on the [Yes] button. 6-16 Installation/Owner's Manual...
  • Page 130: Auto Change Over Operation

    6. Auto control menu Auto change over operation Auto changer over operation is the function to maintain the optimal indoor temperature without any manual control through automatic change over of operating mode (Cool, heat) of the air conditioner. For example, when number of people increase to suddenly raise the indoor temperature during heating operation, AC Smart automatically changes from heat to cool mode to operate the indoor unit of the air conditioner to maintain the indoor temperature at a certain range.
  • Page 131 6. Auto control menu When you press the auto changer over operation tab from the auto control menu, the following screen to set the auto change over operation will be displayed. The group that has been set up for the auto changer over operation and the details of the setting are displayed in table format.
  • Page 132: Setting Auto Change Over Operation

    6. Auto control menu Setting auto change over operation To set the auto change over function, proceed in the following order. . When you press the ʻAuto change over operationʼ tab from the ʻAuto controlʼ menu, the following screen will be displayed. To set the auto change over operation, press the [Condition setting] button.
  • Page 133 6. Auto control menu Item Description Select the group to apply the auto change over operation. Group name This sets the reference temperature to execute auto change over operation. Set temp. The temperature range that can be set is 18°c ~30°c. Set the temperature difference so that the auto change over function can operate.
  • Page 134 6. Auto control menu . It is saved. When the setting is saved, the [Save] button will be deactivated and will be reactivated when the current information changes. Click on the [Close] button to move to the prior screen. Click on [Close] button to return to prior screen 6-21 AC Smart...
  • Page 135 6. Auto control menu Time-limited running The time-limited running automatically stops the operation of the unit after the specified time. The time- limited running can reduce the waste of energy by limiting the individually used time of the unit within a specific time when the administrator is absent.
  • Page 136 6. Auto control menu When you press the time limit operation tab from the auto control menu, the following screen to check the setting of the time limit operation will be displayed. The group and unit that have been set up for the time limited operation operation and the details of the setting are displayed in table format.
  • Page 137 6. Auto control menu Setting the time-limited running Keep the following order to set the time-limited running function. . When you press the ʻTime limit operationʼ tab from the ʻAuto controlʼ menu, the following screen will be displayed. To set the time limit operation, press the [Condition setting] button. Press the [Condition setting] button from the "Time limited operation"...
  • Page 138 6. Auto control menu Item Description Select the group to apply the time limit operation. Group name Set the time (0.5 ~ 4 hours) to limit the running of the time-limited running Operation group. The time-limited running group is run for the set time and then Stop/standby time automatically ended.
  • Page 139 6. Auto control menu . Saving is finished. When saving is finished, [Save] button is deactivated, and when the current information is changed, it is activated again. Click [Close] button to return to the previous screen. Click [Close] button to return to the previous screen ʻAfter Hourʼs Timerʼ...
  • Page 140 6. Auto control menu . Set the day, then non-working time limit control function to select a start time and end time. . If the day is not selected in the previous step, you can not set the days and times. To set all the settings you have completed the time of the day, [Save] button is set to apply.
  • Page 141: History Menu

    7. History menu 7. History menu AC SMART II records the information when there is any change in setting or unit condition. In the history menu, you can classify and check the history by the period or the type of event. History menu can save maximum of 3000 events for 1 month.
  • Page 142: Browsing Specific History

    7. History menu Browsing specific history You can classify the history information displayed on the history screen by setting and type. To classify and browse the history information by time and type, proceed in the following order. . Click on the [Condition setting] button. 'Record search condition' to classify and search the event by history code and period is displayed.
  • Page 143 7. History menu Item Description Error : This sets the history list to display the event related to error. Condition : This sets the history list to display the event related to condition change. View option Manual event : This sets the history list to display the event directly set by the user with the remote controller etc.
  • Page 144 7. History menu Information: Refreshing with latest information While the history information is displayed in the history screen, the setting information and changes can occur. This information is not immediately reflected to the history screen currently displayed. To view the latest history information, click on the [Refresh] button. The history displayed on the screen is refreshed to the latest information.
  • Page 145: Remove All Error Records

    7. History menu Remove All Error Records AC Smart II history to record information on and off of the error can be deleted. [All Error Delete] button to access the installers have access to the History menu will appear. . [All Error Delete] button code value 'E' is deleted, all records, and historical information are rearranged.
  • Page 146: Statistical Menu

    8. Statistical menu 8. Statistical menu With AC SMART II, you can search the operating time of the indoor unit by Zone, Group and Unit. You can search the operating time of the indoor unit for specific period of on a monthly basis. When you select the statistic menu, the following screen will be displayed.
  • Page 147: Accumulative Operating Time

    8. Statistical menu Accumulative operating time Accumulative operating time is the function that calculates the operating time of the indoor unit for a specific period selected by the user. When you press the accumulative operating time tab, the following screen will be displayed. The accumulative You can save the accumulative operating time as a file.
  • Page 148: Searching Accumulative Operating Time

    8. Statistical menu Searching accumulative operating time You can check the accumulative operating time of the indoor unit during the specific period. To check the accumulative operating time, proceed as follows. . Press the ʻAccumulative operating timeʼ tab from the statistical menu and set the period to search the accumulative operating time from the ʻPeriodʼ...
  • Page 149: Monthly Operating Time

    8. Statistical menu Monthly operating time Monthly operating time calculates and provides the monthly operating time of the indoor unit for a specific period (3 months, 6 months, 1 year) from a specific month the user selects. When you press the monthly operating time tab, the following screen will be displayed. You can You can save the monthly operating time information as a file.
  • Page 150: Searching Monthly Operating Time

    8. Statistical menu Searching monthly operating time You can check the operating time of the indoor unit from a specific month for the set period based on the month level unit. . Press the ʻMonthly operating timeʼ tab from the statistical menu and set the month to set as basis to search the monthly operating time from ʻPeriodʼ...
  • Page 151: Setting The Operating Time Search Condition

    8. Statistical menu Setting the operating time search condition You can set the search condition for the accumulative operating time and monthly operating time. To set the search condition, proceed as follows. Accumulative operating time is used as an example. You can also set the search condition for the monthly operating time in the same way.
  • Page 152 8. Statistical menu Type Item Description View by Zone Set the usage information to show by Zone. View by Group Set the usage information to show by Group. View setting View by Unit Set the usage information to show by Unit. Zone selection Set the Zone to show the usage information.
  • Page 153: Saving Operating Time Report File

    8. Statistical menu Saving operating time report file You can save the accumulative operating time information and monthly operating time information that you have searched to an Excel file on the USB memory. To save the result to a file, proceed as follows.
  • Page 154 8. Statistical menu . Message saying that the file is saved is displayed. Press the [OK] button to complete the process. And then you can remove the USB memory from AC SMART II. Press the [OK] button Information: Delete all schedule When AC SMART II is installed for the first time or when there is an error, the statistical information may not be displayed correctly.
  • Page 155: System Menu

    9. System Menu 9. System Menu You can conveniently manage the indoor units and ventilators connected to the network with AC Smart in zone and group depending on the installed location or function characteristic. Setting menu provides the function to include or exclude indoor unit and ventilator from group or zone depending on the physical and logical structure.
  • Page 156: Registering Unit

    9. System Menu Registering unit When first installing AC Smart, you must register the unit to connect to AC Smart. When you press the [Unit registration] button located at the bottom of the unit management menu, the following ʻUnit registrationʼ screen will be displayed. Here you can register a new unit or edit/delete existing units.
  • Page 157: Registering New Unit Automatically

    9. System Menu Registering new unit automatically You can automatically search and register the unit connected to AC Smart. To automatically register the unit, proceed in the following order. . When you select ʻUnit managementʼ menu, the following screen will be displayed. Press the [Unit registration] button located at the bottom right side of the screen.
  • Page 158 9. System Menu . AC SMART II will search and register the units connected. When this process is completed, units automatically registered will be displayed in the table located below the screen. After the unit is searched, the result is displayed. .
  • Page 159 9. System Menu . Lastly, you must register the unit setting that has been temporarily saved to the system. When you click on the [Save] button, an ʻInformationʼ screen to check whether to apply the current setting will be displayed. Click on the [Yes] button. To apply to system, click on [Save] button and click on [Yes] button .
  • Page 160: Directly Registering New Unit

    9. System Menu Directly registering new unit The user can directly register the unit connected to AC Smart. To register the unit, proceed in the following order. . Press the [Register unit] button located at the bottom of the ʻUnit managementʼ menu. Press [Register unit] button .
  • Page 161 9. System Menu Item Description Enter the type of unit. Type - Air conditioner, Ventilator, Eco V DX, On/Off Device, AWHP Unit name Enter the name of the unit. You can enter up to 20 characters. Enter the physical address of the unit. The physical address value is between Address 00 and FF, and cannot be duplicated.
  • Page 162 9. System Menu . 'Information' screen to save the current setting temporarily is displayed. When you click on the [Yes] button, 'Edit unit' screen will be closed and it will return to the prior screen. To apply to system click on [Yes] button .
  • Page 163 9. System Menu . Current setting will be applied to the system and a message saying that the saving is completed will be displayed on the screen. Press the [OK] button to complete the registration. When the saving is completed, press the [OK] button.
  • Page 164: Zone Management

    9. System Menu Zone Management Zone is the logical set of Groups configured around a location of unit function etc. Zone can be composed of several Groups. When executing a specific control command to the specific Zone, all the Groups included in the Zone will execute the same control command. Creating new zone To create a new zone, proceed in the following order.
  • Page 165 9. System Menu . Click on the [Add] button in the system tree screen. 'Zone name' screen to enter the name of the new zone to create is displayed. When you press the [Add] button, the "Zone Group Name" screen is displayed. .
  • Page 166 9. System Menu . Check whether the applicable zone has been created at the lower node of AC Smart node. Check whether zone has been created . Click on the [Save] button to save the setting. Message confirming to save will be displayed on screen.
  • Page 167 9. System Menu 6. After the setting process is displayed on the screen, the save complete message is displayed. When you click on the [OK] button, the save process will be completed. Click on [OK] button to complete saving Reference: Reflecting changed unit list After saving the setting, the list of changed units (Renamed, deleted unit information) will be reflected to the schedule, auto control and statistical function.
  • Page 168: Deleting Zone

    9. System Menu Deleting zone To delete the zone, proceed in the following order. . Select the 'System' menu from the menu of AC Smart. When you select the 'System' menu, the following screen is displayed. Select the zone to delete from the 'System tree' and click on the [Delete] button.
  • Page 169 9. System Menu . Click on the [Save] button to save the setting. Message confirming to save will be displayed on screen. Click on the [Yes] button. After clicking on [Save] button, when "Information screen" is displayed, click on [Yes] button .
  • Page 170: Renaming Zone

    9. System Menu Renaming zone To rename the zone, proceed in the following order. . Select the 'System' menu from the menu of AC Smart. When you select the 'System' menu, the following screen is displayed. Select the zone to rename from 'System tree'. Select zone to rename .
  • Page 171 9. System Menu . After renaming the zone, click on the [OK] button. After renaming the zone click on [OK] button . Check whether the applicable zone has been renamed in 'System tree'. Check whether zone has been renamed 9-17 Installation/Owner's Manual...
  • Page 172 9. System Menu . Click on the [Save] button to save the changes. Message confirming to save will be displayed on screen. Click on the [Yes] button. After clicking on [Save] button when "Information" screen is displayed, click on [Yes] button .
  • Page 173: Group Management

    9. System Menu Group Management Group is a logical gathering of device(indoor unit, Ventilator, Eco V DX, ON/OFF unit, AWHP unit) possible to organize according to location or device function and so on. You can organize group by putting together various devices. When executing some control command to specific group, the devices included at group carry out same control command as well.
  • Page 174 9. System Menu . Reset the group. 'Registered unit' displays group current zone is included and 'Unregistered unit' includes the group not assigned to any zone. Use the [▶] and [◀] button to include or delete the group. Exclude group by ▶...
  • Page 175 9. System Menu . Click on the [◀] button to include the designated group to 'Registered unit'. Applicable group is moved and displayed in 'Registered unit'. ◀ Click on [ ] button to move designated group. Applicable group displayed in "Registered unit"...
  • Page 176 9. System Menu . After the setting process is displayed on the screen, the save complete message is displayed. When you click on the [OK] button, the save process will be completed. Click on [OK] button to complete saving 9-22 AC Smart...
  • Page 177: Creating New Group

    9. System Menu Creating new group To create a new group, proceed in the following order. . Select the 'System' menu from the menu of AC Smart. When you select the 'System' menu, the following screen is displayed. Select the zone to include the new group to from the 'System tree'. Select zone to include newly created group .
  • Page 178 9. System Menu . After entering the name of the group to create, click on the [OK] button. After entering the group name click on [OK] button . Check whether the applicable group is created in the lower node of the selected zone. Check whether the group is created 9-24...
  • Page 179 9. System Menu . Click on the [Save] button to save the setting. Message confirming to save will be displayed on screen. Click on the [Yes] button. After clicking on [Save] button, when "Information" screen is displayed, click on [Yes] button .
  • Page 180: Deleting Group

    9. System Menu Deleting group To delete the group, proceed in the following order. . Select the 'System' menu from the menu of AC Smart. When you select the 'System' menu, the following screen is displayed. Select the group to delete from 'System tree', and click on the [Delete] button.
  • Page 181 9. System Menu . Click on the [Save] button to save the setting. Message confirming to save will be displayed on screen. Click on the [Yes] button. After clicking on [Save] button, when "Information" screen is displayed, click on [Yes] button .
  • Page 182: Renaming Group

    9. System Menu Renaming group To rename the group, proceed in the following order. . Select the 'Setting' menu from the menu of AC Smart. When you select the 'Setting' menu, the following screen is displayed. Select the group to rename from the 'System tree'. Select group to rename .
  • Page 183 9. System Menu . After renaming the group, click on the [OK] button. After renaming Group click on [OK] button . Check whether the name of the applicable group has been renamed in the 'System tree'. Check whether the group has been renamed 9-29 Installation/Owner's Manual...
  • Page 184 9. System Menu . Click on the [Save] button to save the setting. Message confirming to save will be displayed on screen. Click on the [Yes] button. After clicking on [Save] button, when "Information" screen is displayed, click on [Yes] button .
  • Page 185: Unit Management

    9. System Menu Unit Management Unit (Indoor unit, Ventilator, Eco V DX, On/Off unit, AWHP unit) is the smallest control unit linked with AC SMART II. Resetting the unit To reset the unit, proceed in the following order. . Select the 'System' menu from the menu of AC Smart. When you select the 'System' menu, the following screen is displayed.
  • Page 186 9. System Menu . Rest the unit. The unit included in the current group is displayed in 'Registered unit' list and the unit not assigned to any group is displayed in the 'Unregistered unit' list. Press the [▶] and [◀] button, to add or delete the unit.
  • Page 187 9. System Menu . Press the [▶] button, to add the designated group to 'Registered unit'. The applicable unit will be moved and displayed in the 'Registered unit' list. ▶ Press the [ ] to move the designated unit. Applicable unit will be displayed in the "Registered unit".
  • Page 188 9. System Menu . After the setting process is displayed on the screen, the save complete message is displayed. When you click on the [OK] button, the save process will be completed. Click on [OK] button to complete the save process 9-34 AC Smart...
  • Page 189: Deleting Registered Unit

    9. System Menu Deleting registered unit You can delete the unit information connected and registered to AC Smart. To delete the unit information, proceed in the following order. . Select the 'Setting' menu from the menu of AC Smart. When you select the 'Setting' menu, the following screen is displayed.
  • Page 190 9. System Menu . To save the unit you have deleted, click on the [OK] button. 'Information' screen to temporarily save the current setting is displayed. When you click on the [Yes] button, the 'Edit unit' screen will end and return to the prior screen. Click on [Yes] button to...
  • Page 191 9. System Menu . After the setting process is displayed on the screen, the save complete message is displayed. When you click on the [OK] button, the save process will be completed. Click on [OK] button to complete save 9-37 Installation/Owner's Manual...
  • Page 192: Editing Registered Unit

    9. System Menu Editing registered unit You can change the unit information connected and registered to AC Smart. To change the unit information, proceed in the following order. . Select the 'System' menu from the menu of AC Smart. When you select the 'System' menu, the following screen is displayed.
  • Page 193 9. System Menu Item Description Enter the type of unit. - Air conditioner Type - Ventilator, Eco V DX - On/Off Device - AWHP Unit name Enter the name of the unit. You can enter up to 20 characters. Enter the physical address of the unit. The physical address value is between Address 00 and FF, and cannot be duplicated.
  • Page 194 9. System Menu . Click on the [OK] button to save the changes. 'Information' screen to temporarily save the current setting is displayed. When you click on the [Yes] button, the 'Edit unit' screen will end and return to the prior screen. Click on [Yes] button to save to system .
  • Page 195 When the external central controller operates as master, the external central controller gets the right to control some functions. So, when the AC Smart operates as slave, you cannot use schedule, automatic control and detailed lock functions. Multi V LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4...
  • Page 196 9. System Menu In order to set the interconnection with the external central controller, press [Control link] button ʻUnit managementʼ screen. When ʻSet to interconnect with the external central controllerʼ screen is displayed, check the check box at the bottom and press [OK] button. Click [Control link] button.
  • Page 197: 10. Environment Setting

    10. Environment Setting 10. Environment Setting You can check and perform the environment setting function necessary for operating the AC Smart at the Environment Setting menu. The following functions can be set at the Environment Setting menu. • Check the S/W version information of the AC Smart •...
  • Page 198: Checking The S/W Version Information

    10. Environment Setting Checking the S/W version information When you press the Environment Setting menu, you can check the version of the AC SMART II software. The AC Smart can use the USB memory to upgrade the software. Therefore, the user should be able to check the version of the current software and upgrade the version of the software when necessary.
  • Page 199: Password Setting

    10. Environment Setting Password setting Only the user with the right to access the AC Smart should be able to set and control the AC Smart. Keep the following steps to set a new password. There are two access levels; Installation access and administrator access. The installation access uses a fixed password.
  • Page 200 10. Environment Setting . Message to confirm whether to save the changed password will be displayed. Press the [Yes] button. Click [Yes] button to save changed password . The message that the password is changed is displayed. Click [OK] button to finish setting the password.
  • Page 201: Language Setting

    10. Environment Setting Language setting AC SMART II supports the seven following languages depending on the installed country so that the user can easily understand the setting and control information of the units (Indoor unit, ventilator, Eco V DX, On/Off unit). •...
  • Page 202 10. Environment Setting . To apply the change in the displayed language, you must restart AC SMART II. When you see the message asking to restart, press [Yes] to restart AC SMART II. Click [Yes] button to restart the AC Smart .
  • Page 203: Screen Saver Setting

    10. Environment Setting Screen saver setting AC SMART II provides a 7 inch LCD panel to display the information. In the ʻScreen saverʼ tab, you can set the screen saver to protect the LCD panel. Also you can set the LCD to be turned off when there is no entry for a certain period of time to minimize the power consumption.
  • Page 204 10. Environment Setting To set the screen saver function, proceed as follows. . When you press the ʻScreen saverʼ tab from the ʻEnvironment Settingʼ menu, the screen to set the screen saver will be displayed. Enter the information of each item and press the [Apply] button. For detail description of each item, refer to the following table.
  • Page 205 10. Environment Setting . Message to confirm to save the screen saver setting is displayed. Press the [Yes] button to complete the screen saver setting. Press [Yes] button to save the changed screen saver setting 10-9 Installation/Owner's Manual...
  • Page 206: Alarm Setting

    10. Environment Setting Alarm setting In the ʻAlarmʼ tab, you can set the error generated from the unit to be displayed to the user. Also by setting the time to display the alarm, you can set the alarm to be cleared after a certain period of time. To set the alarm function , proceed as follows.
  • Page 207 10. Environment Setting . Message to confirm whether to save the Alarm setting is displayed. Press the [Yes] button to complete the Alarm setting. Press the [Yes] button to save the changed alarm setting . In case of an error in the future, the following alarm screen will be displayed. 10-11 Installation/Owner's Manual...
  • Page 208: Changing The Temperature Display

    10. Environment Setting Changing the temperature display The temperature of AC SMART II is basically displayed in Celsius (°C). But the temperature unit (Celsius, Fahrenheit) can be displayed by the country. You can set the temperature unit displayed on AC SMART II from the ʻTemperature displayʼ tab. To set the temperature unit displayed on the screen, proceed as follows.
  • Page 209 10. Environment Setting . After restarting AC SMART II, the log in screen is displayed. Log in to check whether the set temperature unit is displayed on the screen. 10-13 Installation/Owner's Manual...
  • Page 210: Time Setting

    10. Environment Setting Time setting The AC Smart needs the correct time setting to drive the air conditioner and the ventilator according to the schedule set by the user or to record the history information about the occurred event. You can set the date and the time for setting and controlling the air conditioner and the ventilator at the time setting.
  • Page 211 10. Environment Setting . ʻDate/Time propertiesʼ screen is displayed. Enter the time information and press the [Apply] button to apply the set time information to AC SMART II. For detail description of each input item, refer to the following table. After time information, click [apply] button Item...
  • Page 212: Screen Calibration

    10. Environment Setting Screen calibration To use AC SMART II, you must set all the information through the touch screen method. If the coordinate that the user is operating is not aligned with the coordinate of the touch screen, AC SMART II may not operate as intended by the user.
  • Page 213 10. Environment Setting . ʻStylus propertiesʼ screen is displayed. Press the [Re-calibrate] button from the ʻCalibrationʼ tab. Press the [Re-Calibrate] button . The cross symbol is displayed at the center of the screen. Touch the center of the cross with the stylus.
  • Page 214 10. Environment Setting . When the above procedure is finished, select whether to apply the current screen calibration setting to the system or not. Press the screen with the touch pen to apply it to the system. Click the screen to use the current setting .
  • Page 215: Introduction To Advanced Environment Setting

    11. Introduction to Advanced Environment setting 11. Introduction to Advanced Environment setting With Advanced Environment Setting menu, you can set key function to operate AC SMART II including network, SW upgrade and database backup. The functions that can be set through Advanced Environment Setting are as follows.
  • Page 216: Network Information Setting

    11. Introduction to Advanced Environment setting Network information setting The AC Smart can send/receive the information to/from other external systems via the network. The network function can be set at ʻNetworkʼ for communicating the following external systems. • SVCNet: Send/receive the history information and the current status information of the unit connected to the AC Smart •...
  • Page 217: Remote Service Setting

    11. Introduction to Advanced Environment setting Remote service setting Keep the following steps to set the remote service for accessing the SVCNet. . When you press the ʻNetworkʼ tab from the ʻAdvanced Environment Setting, the screen to set the remote service will be displayed. Enter the remote service setting information and press the [Apply] button.
  • Page 218 11. Introduction to Advanced Environment setting . Message confirming that the network setting has been saved will be displayed. Pres the [Yes] button to complete the network setting. Save changed network setup by pressing <Yes> button 11-4 AC Smart...
  • Page 219: Network Adapter Setting

    11. Introduction to Advanced Environment setting Network adapter setting To smoothly exchange information with SVCNet or PC Client, the network adapter of AC SMART II (IP address, gateway address, DNS etc.) must be set. To set the network adapter, proceed as follows. .
  • Page 220 11. Introduction to Advanced Environment setting . Press ʻIP addressʼ tab and select whether to get the IP address with the DHCP or to directly enter the IP address. When you directly enter the IP address, enter the additional information as shown at the below table.
  • Page 221 11. Introduction to Advanced Environment setting Item Description Primary DNS Enter the IP address of the primary DNS server. Secondary DNS Enter the IP address of the secondary DNS server. Primary WINS Enter the IP address when the WINS is used. Secondary WINS Enter the secondary IP address when the WINS is used.
  • Page 222: E-Mail Setting

    11. Introduction to Advanced Environment setting E-mail setting The E-mail notifies the administrator of the critical error information of the AC Smart by the e-mail. when the administrator is absent. The information about the e-mail to be sent to the user can be set and the account of the e-mail can be set at the ʻE-mailʼ...
  • Page 223 11. Introduction to Advanced Environment setting Keep the following steps to set e-mail. . When you select the ʻEmailʼ tab from the ʻAdvanced Environment Settingʼ menu, the email setting screen will be displayed. You must first set the account to send the email. Press the [Account management] button.
  • Page 224 11. Introduction to Advanced Environment setting Classification Item Description (CHECK SMART) User name Enter the userʼs name. User Information E-mail address Enter the userʼs e-mail address. Sending mail server Server Enter the mail server address. information (SMTP) Server information Sending mail server port Enter the mail server port.
  • Page 225 11. Introduction to Advanced Environment setting . When the account setting test is successfully performed, the finish message is displayed. Press [OK] button to end testing. Click [OK] button . When it returns to ʻE-mail account settingʼ screen, press [Apply] button to save the set account information.
  • Page 226 11. Introduction to Advanced Environment setting . Message to confirm to save the changed information is displayed. Press the [Yes] button to save the setting. Press the [Yes] button . When it returns to the email setting screen, enter the email information. For description of each item, refer to the following table.
  • Page 227 11. Introduction to Advanced Environment setting Item Description Set whether to use ʻSend the e-mailʼ function or not. Email usage setting Enter the e-mail Enter the subject of the e-mail to be sent to the receiver. You can enter it up to subject 40 characters.
  • Page 228: Statistical Reference Date Setting

    11. Introduction to Advanced Environment setting Statistical reference date setting Statistical reference date is the date to calculate the operating time of the indoor unit for 1 month. Here the operating time is calculated from the reference date to 1 day prior to the reference date in the following month, and provided as statistical information in the statistical menu.
  • Page 229 11. Introduction to Advanced Environment setting . Message to confirm to save the statistical reference date is displayed. Press the [Yes] button. Press the [Yes] button to save the changed statistical reference date . Message to ask whether to save the statistical reference date to the current month is displayed. Press the [Yes] button to complete the statistical reference date setting.
  • Page 230: Software Upgrade

    11. Introduction to Advanced Environment setting Software upgrade The AC Smart can use the USB memory to upgrade the software of the AC Smart. Keep the following steps to upgrade the software of the AC Software. Note: Before upgrading the software Before upgrading the software, the left USB port of the AC Smart should be connected to the USB device containing the software update image.
  • Page 231 11. Introduction to Advanced Environment setting . The message showing that it takes some time to upgrade the software is displayed. Press [OK] button. Click [OK] button . Message showing that it requires time to upgrade the software is displayed. Press the [OK] button. Click [OK] button 11-17 Installation/Owner's Manual...
  • Page 232 11. Introduction to Advanced Environment setting . Progress of the software update is displayed in percentage. . When the procedure of the S/W upgrade is finished, the message showing that the system is to be restarted is displayed. When you press [OK] button, upgrading is ended. And then, the AC Smart is restarted and the Login screen is displayed.
  • Page 233: Database Back Up And Restoring

    11. Introduction to Advanced Environment setting Database back up and restoring The AC Smart can back up the critical database to the external USB memory. Also, it can also retrieve the saved database from the external USB memory to restore. When you press the ʻDBʼ...
  • Page 234: Backing Up The Database

    11. Introduction to Advanced Environment setting Backing up the database Keep the following steps to export the database to the USB memory. . When you press the ʻDB administrationʼ tab from the ʻEnvironment Settingʼ menu, the following screen will be displayed. To back up the database, press the [Proceed] button next to the DB back up item.
  • Page 235: Restoring The Database

    11. Introduction to Advanced Environment setting Restoring the database Keep the following steps to import the database into the AC Smart. . When you press the ʻDB administrationʼ tab from the ʻEnvironment Settingʼ menu, the following screen will be displayed. To restore the database, press the [Proceed] button next to the DB restore item.
  • Page 236 11. Introduction to Advanced Environment setting . When the database is successfully restored, the AC Smart program is restarted and the Login screen is displayed. 11-22 AC Smart...
  • Page 237: Introduction To Web Server Function

    12. Introduction to web server function 12. Introduction to web server function AC SMART II provides the web server function so that the administrator can connect and control AC SMART II remote by connecting to the network. Through this, the administrator can monitor and control units in other locations (Indoor unit, Ventilator, Eco V DX, On/Off unit, AWHP unit).
  • Page 238 12. Introduction to web server function Record menu "Record" menu is similar to the "Record" menu of AC SMART II. In this menu, you can check the unit error and condition information of AC SMART II and the units by period. User management menu In the "User management"...

This manual is also suitable for:

V-net ac smart iiV-net advanced control smart

Table of Contents