– The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.
Page 3
Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product.
Page 4
Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning.
Contents Introduction ......7 Concept and target groups for this manual ..7 Documentation overview .
Page 6
Contents 6.1.1 Controls and indicators on the server node ... . 39 6.1.1.1 Control elements ..... . . 40 6.1.1.2 Global error indicator, ID indicator, CSS indicator .
This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY CX2550 M1 server node into operation. To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.
Introduction Documentation overview More information on your PRIMERGY CX2550 M1 server node can be found in the following documents: – "ServerView Suite Quick Start Guide" – "Safety Notes and Regulations" manual " 安全上のご注意 " for the Japanese market – "Warranty" manual "...
Introduction For the Japanese market: Before using the product, please check for additional information that may be available under the following URL: http://jp.fujitsu.com/platform/server/primergy/products/note/ Further sources of information: – ServerView Suite Glossary – Manual for the monitor – Documentation for the boards and drives –...
Page 12
Further information on other SAS/SATA RAID controllers (e.g. for operating external SAS/SATA hard disk drives or tape drives) is available on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS / SCSI RAID Controllers.
Page 13
Internal Event Log for user login / logout auditing ● More information about the iRMC S4 can be found in the "iRMC S4 - integrated Remote Management Controller" user guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Out-Of-Band Management). Operating Manual...
Page 14
Functional overview ® Cool-safe Advanced Thermal Design ® The Cool-safe Advanced Thermal Design option allows you to operate the system within a wider temperature range of 5 °C to 40 °C. This option can only be ordered from the manufacturer and is indicated by the logo on the identification rating plate.
Functional overview Server node specification This section explains the specifications for the server node. The specifications for this server node are liable to be updated without any notice. Please be forewarned. System Board System board type D3343 ® Chipset Intel C610 Processor ®...
Page 16
C610, for up to 6 x SATA HDDs/SSDs SW Raid 0/1 RAID controllers (expansion cards) RAID controllers – RAID Ctrl., SAS/SATA 12 Gbit/s, Fujitsu PRAID CP400i, 8 ports int. RAID level: 0, 1, 1E, 10, 5, No BBU support – RAID 5/6 Ctrl., SAS/SATA 12 Gbit/s, Fujitsu PRAID EP420i, 8 ports int.
Page 17
Functional overview Operating Panel Operating buttons ID button On/Off button Operating LEDs On/Off (green) System status (orange) LAN speed (green / yellow) LAN connection (green) Identification (blue) Dimensions / Weight Rack (W x D x H) 1 HU half wide (175.5 mm x 520 mm x 40.8 mm) Weight 4 kg (full populated incl.
Page 18
Functional overview Compliance with regulations and standards Product safety and ergonomics International IEC 60950-1 2ed; am1 Europe Safety EN 60950-1 2ed.; am1 EN 62479 EN 62311 Ergonomics ISO 9241-3 EN 2941-3 EK1-ITB2000:2013 USA / Canada CSA-C22.2 No. 60950-1-07 2ed. UL 60950-1 2ed. Taiwan CNS 14336 China...
Installation steps, overview This chapter contains an overview of the steps necessary to install your server node. Links take you to sections where you can find more detailed information about the respective steps: Ê First of all, carefully read the safety instructions in "Important information"...
Page 20
You will find more information on installing the server node remotely or locally in the "ServerView Suite Installation Manager" user’s guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Server Installation and Deployment). Operating Manual...
Important information In this chapter you will find essential information regarding safety when working on your server node. Safety instructions The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安全上のご注意 ". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server node in the intended environment, please contact your sales outlet or our customer service team.
Page 22
Important information Before starting up CAUTION! During installation and before operating the device, observe the ● instructions on environmental conditions for your device (see "Server node specification" on page 15). If the server node has been moved from a cold environment, ●...
Page 23
Important information CAUTION! Ensure that the power sockets on the device and the properly ● grounded power outlets are freely accessible. The On/Off button or the main power switch (if present) does not ● isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets.
Page 24
Important information CAUTION! Proper operation of the system (in accordance with IEC 60950-1/2 ● resp. EN 60950-1/2) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression).
Page 25
Replace the lithium battery on the system board in accordance with ● the instructions in the "FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual". All batteries containing pollutants are marked with a symbol (a ●...
Page 26
Important information Working with CDs/DVDs/BDs and optical drives When working with devices with optical drives, these instructions must be followed. CAUTION! Only use CDs/DVDs/BDs that are in perfect condition, in order to ● prevent data loss, equipment damage and injury. Check each CD/DVD/BD for damage, cracks, breakages etc.
Page 27
Important information Do not contaminate the CD/DVD/BD surface with fingerprints, oil, ● dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth. Be careful not to damage the CD/DVD/BD surface.
Page 28
Important information Modules with Electrostatic-Sensitive Devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When you handle components fitted with ESDs, you must always observe the following points: Switch off the system and remove the power plugs from the power outlets ●...
Important information Other important information: During cleaning, observe the instructions in section "Cleaning the server ● node" on page Keep this operating manual and the other documentation (such as the ● Upgrade and Maintenance manual, documentation DVD) close to the device.
Consult the dealer or an experienced radio/TV technician for help. ● Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
Page 32
Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
Hardware installation CAUTION! Follow the safety instructions in the chapter "Important information" ● on page Do not expose the server node to extreme environmental conditions ● (see "Ambient conditions" on page 17). Protect the server node from dust, humidity and heat. Make sure that the server node is acclimatized for the time indicated ●...
Hardware installation Unpacking the server node CAUTION! Follow the safety instructions in "Important information" on page Do not unpack the server node until it is at its installation location. Ê Transport the server node to the place where you want to set it up. Ê...
Connecting devices to the server node The additional connectors available on your server node depend on the expansion cards installed. For further information refer to the “FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual”. The standard connectors are marked with symbols, and some are color-coded:...
Page 36
Hardware installation Connecting the keyboard, mouse and monitor Ê Connect the keyboard and mouse to the USB connectors of the server node. Ê Connect the monitor to the video connector. If a separate graphics card is installed in a slot, the graphic controller on the system board is automatically deactivated.
Hardware installation Notes on connecting/disconnecting cables CAUTION! Always read the documentation supplied with the device you wish to connect. Never connect, or disconnect cables during a thunderstorm. Never pull on a cable when disconnecting it. Always take hold of the cable by the plug.
ID indicator Global error indicator CSS inidicator The server nodes are controlled via related operating panel areas on the front side of the CX400 M1 server enclosure. See "FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual". Operating Manual CX2550 M1...
CAUTION! Risk of loss of data! The server nodes are controlled via related operating panel areas on the front side of the CX400 M1 server enclosure. See "FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual". 6.1.1.2 Global error indicator, ID indicator, CSS indicator Global error indicator (orange) –...
Page 41
Starting up and operation CSS indicator (yellow) – Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself (for reasons of precaution) with the CSS concept. – Flashes yellow if an error was detected that you can fix yourself with the CSS concept.
Depending on the settings in the BIOS, the standard LAN connector 1 may also be used as a Management LAN connector. You will find further information in the "D3343 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M1 Reference Manual".
The multi-node server system consists of up to four server nodes. Each server node installed in the server enclosure works independently. The server nodes are controlled via related operating panel areas on the front side of the CX400 M1 server enclosure. See "FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual". CAUTION! It nothing appears on the screen but flickering stripes after switching ●...
Page 44
Ê Shut down the operating system properly. The server nodes are controlled via related operating panel areas on the front side of the CX400 M1 server enclosure. See "FUJITSU Server PRIMERGY CX400 M1 Server Enclosure Operating Manual". If the operating system does not switch the server node off automatically, press the On/Off button for at least four seconds and/or send a corresponding control signal for power button override.
Page 45
Starting up and operation Other On/Off options Besides the On/Off button, the server can be switched ON and OFF in the following ways: – Wake up On LAN (WOL) The server is switched on by a command via the LAN (Magic Packet™). –...
For further information, refer to the "Embedded MegaRAID Software User’s Guide" (on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI RAID / SCSI Controllers). The PDF files of the manuals can also be downloaded free of charge from the Internet.
Starting up and operation 6.3.3 Operating system installation When starting up a PRIMERGY CX2550 M1 server node for the first time, there are several installation options, depending on the system configuration: – Local USB installation Instead of network booting, you can also boot and install your PRIMERGY CX2550 M1 server node from local USB media.
Starting up and operation Cleaning the server node CAUTION! Switch the server node off and disconnect the power plugs from the properly grounded power outlets. Do not clean any interior parts yourself; leave this job to a service technician. Do not use any cleaning agents that contain abrasives or may corrode plastic.
By combining these options, you can also achieve optimum protection for your system. A detailed description of the Security menu and how to assign passwords can be found in the "D3343 BIOS Setup Utility for FUJITSU Server PRIMERGY CX2550 M1 Reference Manual". Operating Manual...
Page 50
Property and data protection Operating Manual CX2550 M1...
Troubleshooting and tips CAUTION! Follow the safety instructions in the "Safety notes and regulations" manual or " 安全上のご注意 " and in chapter "Important information" on page If a fault occurs, attempt to resolve it using the measures described: – in this chapter, –...
Troubleshooting and tips Screen remains blank Monitor is switched off Ê Switch on your monitor. Screen has gone blank Ê Press any key on the keyboard. Ê Deactivate screen saver. Enter the appropriate password. Brightness control is set to dark Ê...
Troubleshooting and tips Monitor does not support the set horizontal frequency Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor. Ê...
If the date and time are still wrong after the server node has been switched off and back on again, replace the lithium battery (for a description refer to the "FUJITSU Server PRIMERGY CX2550 M1 Server Node Upgrade and Maintenance Manual") or contact our customer service team.