Removing And Reinstalling The Main Parts; Adjustment - Sharp CD-PC672 Service Manual

Table of Contents

Advertisement

CD-PC672

REMOVING AND REINSTALLING THE MAIN PARTS

CD MECHANISM SECTION
Perform steps 1, 2, 3 and 10-14 of the disassembly method to
remove the CD mechanism.
How to remove the loading motor
(See Fig. 12-1)
1. Remove the screws (A1) x 2 pcs., to remove the loading
motor.
How to remove the pickup (See Fig. 12-2)
1. Remove the screws (B1) x 2 pcs., to remove the shaft (B2).
2. Remove the stop washer (B3) x 1 pc., to remove the gear
(B4).
3. Remove the pickup.
Note
After removing the connector for the optical pickup from the
connector, wrap the conductive aluminium foil around the
front end of connector to protect the optical pickup from
electrostatic damage.
MECHANISM SECTION
• Driving Force Check
Torque Meter
Play: TW-2412
• Torque Check
Torque Meter
Play: TW-2111
30 to 60 g. cm
Fast forward: TW-2231
Rewind: TW-2231

ADJUSTMENT

Specified Value
Tape 1: Over 80 g
Tape 2: Over 80 g
Specified Value
Tape 1
Tape 2
30 to 60 g.cm
60 to 120 g.cm
60 to 120 g.cm
Loading / Up
/ Down Motor
Motor
PWB
( B1 ) x2
ø2.6 x6mm
Shaft
( B2 ) x1
• Tape Speed
Test Tape
Normal
MTT-111
speed
TAPE MECHANISM
Volume in motor
– 12 –
( A1 ) x2
ø2.6 x5mm
Figure 12-1
Stop Washer
( B3 ) x1
Pickup
CD Mechanism
Gear
( B4 ) x1
Figure 12-2
Adjusting
Specified
Instrument
Point
Value
Connection
3,000 ±
Volume in
Speaker
motor.
30 Hz
terminal
(MM1)
(Load
resistance:
8 ohms)
MM 1
Motor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents