8-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance, and conduct the dielectric strength
test.
Insulation resistance:
Dielectric strength test: AC 4,000 V/1 minute, with no abnormalities
8-7. No-Load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) max.
7 M
or more with DC 500V Megohm Tester
AC 2,500 V/1 minute, with no abnormalities
110
115
3.2
3.0
• • • • • • • • • • • • • •
• • • • • • • • • • • • • •
220
230
1.7
1.7
--- 16 ---
220 V --- 240 V products
110 V --- 127 V products
240
1.6